9
www.acclaimlighting.com
Power and control wiring
AL Graze DC fixtures use Chogori™ Standard (22) series IP67
connectors for their inputs and outputs. The connector
placements at each end of every fixture are such that abutted
fixtures can be directly connected without need for extra link
cables:
•
AL Graze DC CV
units require a regulated 24VDC power
input only and so use 2-pin connectors. Dimming can
be achieved using either a 24VDC constant voltage (CV)
dimming driver or, where integration into a mains level
dimmed installation is required, use a MLV (Magnetic Low
Voltage) dimmable transformer, such as the M-Series from
Acclaim Lighting.
•
AL Graze DC DMX
units require both a regulated 24VDC
power input as well as DMX control and so use 5-pin
connectors. The final fixture in the line should have a 120Ω
terminating resistor connected between the DMX + and
DMX – lines.
The required feed-in cables (available as separate purchase)
also include pluggable terminal sockets (5.08mm pitch) at the
external end for rapid connections. The cable designations are
as follows:
Connections to
feed cables are best
protected within
junction boxes with
suitable IP ratings
AL Graze DC CV
3’ (10m)
feed-in cable
24VDC only
[Part #: AGEFC10]
Chogori™
22 series
2-pin
AL Graze DC DMX
3’ (10m)
feed-in cable
24VDC and DMX
[Part #: AGDFC10]
Chogori™
22 series
5-pin