background image

www.acclaimlighting.com

AL Graze AC

User guide

Summary of Contents for AL Graze AC 2700K white

Page 1: ...AL Graze AC User guide...

Page 2: ......

Page 3: ...er 6 Fitting extender bars 7 Power and control cabling 8 In rush currents 8 Interconnecting 8 Maximum number of fixtures 9 DMX channel designations 9 OPERATION 10 Making a temporary control link with...

Page 4: ...rnal DMX input all within a combined IP66 protected input link RDM Remote Device Management is used via the DMX link to configure the addressing and mode options see page 11 The range of emitter color...

Page 5: ...us two additional flat brackets and grub screws DMX RDM tool plus male 5pin XLR lead XMT350 Link cables 1 30cm AGHLC1 5 1 5m AGHLC5 10 3m AGHLC10 Feed cables plus end cap terminator AGHFC10 10 3m End...

Page 6: ...riate screws bolts If necessary use a 1 16th 1 5mm Allen wrench to loosen each mount bracket to allow them to slide along the length of the fixture to the required position before re tightening Note I...

Page 7: ...n slide the bracket to the center of the fixture where the rails widen to allow the feet of the bracket to be released Where AL Graze AC fixtures do not need to be tilted and need to be closer to the...

Page 8: ...both sizes of AL Graze AC fixture these can be quickly fitted to eliminate all sideways light spill TO FIT A LOUVER 1 Lower the louver over the front face of the AL Graze AC until the four tabs of the...

Page 9: ...aze AC fixture Note When feeding cables through the extender bar check for any metal burrs that may have formed during manufacture take care not to snag cables Slot in underside can be used to feed ca...

Page 10: ...y effect when a handful of units are powered on at the exact same time However if many fixtures are linked to the same power input they will momentarily pull a current that may greatly exceed their no...

Page 11: ...ummarized in the table below The channel allocations above are shown beginning at DMX address 1 When you configure a fixture with an alternative DMX address that value will become the first channel in...

Page 12: ...are recommended to check that the correct one is set for your color model see page 12 Various third party DMX RDM tools are available we recommend the Acclaim Lighting XMT 350 for this task MAKING A T...

Page 13: ...S PATCH TO ADDRESS OK CANCEL 001 001 The fixture that is highlighted within the list should begin flashing its emitters to identify itself 4 On the XMT 350 press the right arrow button to change to th...

Page 14: ...in a pre arranged daisy chain configuration 2 Power on the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use the arrow buttons to highlight the RDM function and press the butto...

Page 15: ...ures in a pre arranged daisy chain configuration 2 Power on the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use the arrow buttons to highlight the SEND function and press the...

Page 16: ...no damage to the power input cord Use an RDM tool such as the Swisson XMT 350 to check the settings and internal temperature of the fixture Using an RDM tool check that the DMX address set within the...

Page 17: ...512 A RDM configuration Ingress protection IP66 wet location Fixture connectors Cretop IP67 rated Combined AC power DMX control Maximum lengths in series 50 15m 120VAC 100 30m 277VAC Power input 100 2...

Page 18: ...lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in mate...

Page 19: ......

Page 20: ...www acclaimlighting com...

Reviews: