LOOP
LOOP
DETECT
OR
AC220V IN
OUT
Auto-Open
NC
+12V-
1.When the barrier is Closing, if the
photocell ray is shut off ,the barrier
opens instantly.
2.When the barrier is Close, if the
photocell ray is shut off ,the barrier
opens instantly.
3.When the barrier is Open, the
barrier keeps OPEN status if the
Photocell ray is shut off.
Photocell(N.O.)
Loop Detector(N.O.)
1.When the barrier is Closing, if a
car is in the range of sensor ,the
barrier opens instantly.
2.When the barrier is Close, if a
car is in the range of sensor ,the
barrier opens instantly.
3.When the barrier is Open, the
barrier keeps OPEN status if the
Photocell ray is shut off.
NC
Photocell
input must
be bridged if not used
1.When the barrier is closing, if the
photocell ray is shut off ,the barrier
opens instantly.
2.When the barrier is open, the
barrier keeps OPEN status if the
Photocell ray is shut off.
LOOP
LOOP
DETECT
OR
AC220V IN
OUT
PHOTOCELL
GND
N.C.
Loop Detector(N.C.)
1.When the barrier is Closing, if a
car is in the range of sensor, the
barrier opens instantly.
2.When the barrier is Open, if a car
is in the range of sensor, the
barrier is keep OPEN status.
Photocell(N.C.)
Safety opening