Access ROYALE Installation & Operating Instructions Manual Download Page 5

CONSTRUCTION

The tub surface is made of Lucite XL® Acrylic. The 
substructure is a composite laminate constructed of fire 
retardant fillers.

ELECTRICAL

Wired for 110 Volt 20 Amps with 3 outlets one for each 
component (pump, blower, chromalight). Ground-Fault Circuit 
Interrupter (GFCI) is required.

The unit must be connected only to a supply circuit that is 
protected by a Ground-Fault Circut Interrupter (GFCI). Such 
a GFCI should be provided by the installer and should be 
tested on a routine basis.To test the GFCI push the test button. 
The GFCI should interrupt power. Push the reset button. The 
power should be restored. If the GFCI fails to operate in 
this manner, there is a ground current flowing indicating the 
possibility of an electrical shock.

ELECTRICAL ROUGH-IN
WARNING:

 When using electrical products basic precautions 

should always be followed including the following: Rough-in 
wiring to equipment on a Ground-Fault Circuit Interrupter 
(GFCI). The GFCI circuit breaker must not supply any other 
devices or circuits. An access panel must be installed to 
permit pump service.

WARNING:

 Failure to follow instructions exposes users to 

risk of electrical shock or fire.

PLUMBING ROUGH-IN

The bath waste pipe protrudes below the base approximately 
one inch. Provide supply pipe, rough-in waste and vent per 
local code.

BATH WASTE AND OVERFLOW

Read instructions enclosed with bath waste drain for proper 
setting and fitting. Water tight installation of the drain is the 
installer’s responsibility.

IT IS THE INSTALLERS RESPONSIBILITY TO

SUPPLY ACCESS TO PUMP AND EQUIPMENT.

1.  For Caulking, we recommend 100% sanitary silicone 

rather than latex.

2.  For quieter operation, you may choose to insulate the 

surrounding.

PROTECTION OF TUB

Use a section of the box, cut to size, and place in the bottom 
of the tub. When possible, keep the box cover over the tub. 
These steps will help protect the tub from abrasion or dam-
age during installation.

CLEAN PUMP SYSTEM

After tub is installed and ready to use, remove all construc-
tion debris and clean the pump and system.

SUGGESTION:

 During construction, we suggest that you 

cover tub to avoid use as trash receptacle.

TESTING

Connect trap to bath waste pipe. Temporarily connect garden 
hose for water testing. Tub must be clean before filling. Seal 
drain with plug and fill tub 2” above jet fittings. Run pump ap-
proximately 20 minutes. Check for leaks. Turn pump off and 
let water sit in tub about 5 minutes. Check for leaks in return 
pipe and fittings. Drain the tub and shut off circuit breaker.

NOTE: ALL TUBS ARE FACTORY TESTED FOR PROPER 
WATERTIGHT OPERATION. 

However, the tub must be 

filled with water to check for leaks that may have resulted 
from handling, before finishing the tub installation. ACCESS 
Tubs is not responsible for any defects that could have been 
discovered, repaired or avoided by following this testing and 
inspection procedure.

GENERAL NOTES

INSTALLATION

Summary of Contents for ROYALE

Page 1: ...RUCTIONS INSTALLATION OPERATING INSTRUCTIONS ACCESS TUBS 5701 NW 35 Avenue Miami FL 33142 Phone 877 249 2388 Fax 866 560 1060 info accesstub com http www accesstub com MODEL ROYALE Costco Model 1075666 1075667 WHIRLPOOL BATHTUBS ...

Page 2: ......

Page 3: ...T SAFETY INSTRUCTIONS Read and follow all instructions and save these instructions WARNING Examine all plumbing for damage and water test before final installation If damage has occurred call our Technical Service Department at 877 249 2388 WARNING Alterations or modifications of the plumbing system without expressed written authorization will invalidate all warranty claims WARNING Installation mu...

Page 4: ...ithout the guard over the suction fitting 5 The unit must be connected only to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button The power should be restored If the GFCI fails to operate in th...

Page 5: ...uctions enclosed with bath waste drain for proper setting and fitting Water tight installation of the drain is the installer s responsibility IT IS THE INSTALLERS RESPONSIBILITY TO SUPPLY ACCESS TO PUMP AND EQUIPMENT 1 For Caulking we recommend 100 sanitary silicone rather than latex 2 For quieter operation you may choose to insulate the surrounding PROTECTION OF TUB Use a section of the box cut t...

Page 6: ...apeutically relaxing and rejuvenating bathing experience Fiberglass reinforced high grade acrylic Lustrous glossy white finish 8 fully directional and adjustable whirlpool powered jets white finish 24 bubble massage powered air injectors white finish Trim matching white finish cable driven waste and overflow Aromatherapy scent infused massage bubbles Chromatherapy color light bathing Center drain ...

Page 7: ...PREPARATION 1 Clean level and prepare the floor for installation 2 Place the unit in the exact installed position on the floor and trace the outline of the bath with a pencil or any erasable marking figure 1 Figure 1 3 Determine the location of the drain pipe on the floor by taking measurements of the drain and waste location underneath the unit figure 2 Figure 2 4 Using a blanket cardboard or oth...

Page 8: ...INSTALLATION CONTINUED ...

Page 9: ...the tub with water to the overflow and then drain the tub while inspecting the waste connections below the floor for leaks Access from below will be necessary for this step figure 8 Figure 8 20 With the bathtub now in place wipe off any excess tub and tile caulk and adhesive where the tub meets the floor 21 Run a bead of tub and tile caulk around the bottom edge of the bathtub where it meets the f...

Page 10: ... 20 AMP GFCI with 3 outlets one for each component pump blower chromalight Ground Fault Circuit Interrupter GFCI is required The GFCI breaker must not supply any other circuits or devices FINISHING Before finishing with your choice of material make sure access entries are available to the pump bath waste and plumbing fixtures Finish as desired and seal around tub preferably with silicone NOTE 1 Fo...

Page 11: ... Chromalight Press Button Twice Cycle through the available modes and colors Press Once Deactivate Chromalight 4 Bubble Massage On Off Button Press once to turn on the air pump and activate the Bubble Massage air jets Press again to turn off pump and deactivate air jets 5 2nd Whirlpool Pressure Adjustor Use to adjust the strength and pressure of the whrilpool jets 6 Aromatherapy Cap Unscrew to ins...

Page 12: ...g and removing the 4 plastic nubs and loosening the securing screws underneith Then the entire shell can easily be removed If the tub is fully installed but must be uninstalled for maintenance or repair the caulking must be removed completely the tub must be cleaned and new caulking is to be applied for reinstallation ...

Page 13: ...wo 2 times Wipe off the surface after the rinse because the bleach may discolor some color trimmings After using bleach or dishwasher soap you should follow this cleaning procedure Fill the tub with water and run the pump for 5 minutes then rinse it 2 times Clean with a soft damp cloth do not use abrasive cleaners as they may scratch and dull surface of the unit HEAT STROKE The most susceptible pe...

Page 14: ...ten notice of any malfunction or defect must be given within ten 10 days of the time it is discovered to Access Tubs 5701 NW 35th Avenue Miami Florida 33142 Access Tubs reserves the right to inspect the malfunction or defect on location RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user T...

Page 15: ...NOTES INSTALLER INFORMATION DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE ...

Page 16: ......

Page 17: ...Please leave owner s manual with warranty If you have any problems or questions during installation please call technical service at 877 249 2388 Record the numbers here for handy reference Model No Serial No Date of Purchase Manufactured by Access Tubs A Division of Spa World Corp 5701 NW 35th Avenue Miami Florida 33142 Ph 877 249 2388 Fax 866 560 1060 10 1011 WHIRLPOOL BATHTUBS ...

Reviews: