3.5 Document reader software status messages
Messages display in bottom left corner of ADRS. Use these messages to check the status of the
reader and software and to help diagnose problems.
Table 4: Document reader software status messages
Message
Description
ATOM is ready
ATOM is switched on, connected to the host and ready to read a
document.
Scanning
ATOM is acquiring images.
Writing Multiple Image file
ATOM is acquiring images and saving these to disk.
Set this mode from the software's
Configuration
tab.
Processing complete
ATOM has processed the document.
Automatic reader not started
An attempt to start the reader was made, but it failed. This
generally indicates that the automatic detection of documents
placed on the scanner is not enabled (on the
Configuration
tab).
The setting is enabled by default.
No Document Reader Connected ATOM is disconnected from the host and software; the camera
will not work. Check USB and power connections.
Could not set Windows Handle
for windows....
Another instance of ADRS is already running. Ensure that you
close ADRS before restarting.
Initialised
The scanner is initialised, but the reader has not started correctly.
Make sure the scanner is powered up and switched on.
MRZ decoding failed
ATOM has detected an MRZ string that is not correctly formatted.
Move the mouse cursor over the MRZ summary icon to display
details of the failure.