6.8 AUTOMATIC LUBRICATION
6.8.1
GENERAL
Automatic lubrication is an option for lifts with a lower travel than 8 meter. For lifts over 8 meters it is
included in the standard delivery.
6.8.2
INSTALLATION
• The tank for the automatic lubrication is delivered in a separate box. At installation it has to be
mounted at the top of the mast. The tank is fastened with Velcro, the blue hose shall be connected
to the tank-outlet, adjust the length so the hose stops close to the driving-screw. Connect the electri-
cal wires shall be connected to the pump (cables are interchangeable)
• Fill the plastic container in the top of the mast with oil. See Fig. 144
. Fill the
container with oil until it is 1 centimeter left to the edge of the container, see pos 1.
Fig. 144 Automatic lubrication
• The hose shall be flushed against the screw according to Fig. 144
.
• Make the oil lubrication settings on the U1 board with the dip switches. See Fig. 145
setting for oil lubrication on U1 control board
.
122
7000 100 en-GB AD
Summary of Contents for 7000
Page 1: ...Vector Installation Manual HQ ...
Page 23: ...ASSEMBLY 5 ASSEMBLY 5 1 FIXINGS 7000 100 en GB AD 19 ...
Page 25: ...ASSEMBLY Fig 15 Mast preparation before installation 7000 100 en GB AD 21 ...
Page 27: ...ASSEMBLY Lift the top section 7000 100 en GB AD 23 ...
Page 33: ...ASSEMBLY 7000 100 en GB AD 29 ...
Page 34: ...ASSEMBLY 30 7000 100 en GB AD ...
Page 42: ...ASSEMBLY The mast shall stand upright the tolerance is Max 2 mm m 38 7000 100 en GB AD ...
Page 70: ...ASSEMBLY Fig 59 Mounting of Filled wall panels 66 7000 100 en GB AD ...
Page 72: ...ASSEMBLY Fig 61 Principal drawing Shaft corners 68 7000 100 en GB AD ...
Page 100: ...This page is intentionally left blank 96 7000 100 en GB AD ...
Page 117: ...OPTIONS Fig 126 Electrical connections external door opener 7000 100 en GB AD 113 ...
Page 140: ...This page is intentionally left blank 136 7000 100 en GB AD ...
Page 142: ...This page is intentionally left blank 138 7000 100 en GB AD ...