background image

INTRODUCTION

The KP-KR

16

 is a two relay multifunction standalone access control keypad

 

suitable for either indoor or 

outdoor use It is housed in a strong, sturdy and vandal resistant Zinc Alloy electroplated case. The electronics 
are fully potted making it extremely weather resistant and conforming to IP68  
It supports up to 1200 users in a Card, PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ 
EM frequency card or key fob, and the Pin length is 4-8 digits 
Both of the two relays can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for 
arming/disarming alarms, switching lights, machines….etc)  
The 

KP-KR16

 has many extra features including block enrollment, backlit keypad. These features make the 

KP-KR16

 an ideal choice for door access not only for small shops and domestic households but also for 

commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons 

Features 

Weather resistant to IP68

Strong Zinc Alloy Electroplated anti-vandal case

Two relay operation

Both relays can be programmed for 3 modes: Card, PIN, Card + PIN

1200 user capacity

Zone 1: up to 1100 Pin & Card holders, Zone 2: up to 100 Pin & Card holders

Pin length: 4-8 digits; card type: 125KHZ EM card/key fob

Can be used as a standalone keypad

Pulse mode, Toggle mode

Block enrollment, can enroll 1100 consecutive cards within 2 minutes

Backlit keypad

Adjustable Door Relay Output time, Alarm time, Door Open time

Built in light dependent resistor (LDR) for anti-tamper

Built in buzzer

Dual relay outputs for door opening, door status detecting, open door by button

Red, Yellow and Green LEDS display the working status

Supports door bell connection (For relay 2)

12-24V AC/DC power input

ACCESS 

SECURITY 

PRODUCTS 

LTD

Summary of Contents for KP-KR16

Page 1: ...KP KR16 Stand Alone Keypad Proximity Card Reader User Manual A C C E S S S E C U R I T Y P R O D U C T S L T D ...

Page 2: ...nly for small shops and domestic households but also for commercial and industrial applications such as factories warehouses laboratories banks and prisons Features Weather resistant to IP68 Strong Zinc Alloy Electroplated anti vandal case Two relay operation Both relays can be programmed for 3 modes Card PIN Card PIN 1200 user capacity Zone 1 up to 1100 Pin Card holders Zone 2 up to 100 Pin Card ...

Page 3: ...8 Adjustable Door Relay time 1 99 seconds Adjustable Alarm Time 0 3 minutes Wiring Connections Electric Lock Exit Button DOTL External Alarm Dimensions H 135 x W 58 x D 28 mm Net Weight 650g Gross Weight 800g Packing List Name Quantity Remarks Digital Keypad KP KR16 1 User manual 1 Screw driver 1 Rubber bungs 4 6 27mm used for fixing Self tapping screws 4 3 5 27mm used for fixing Please ensure tha...

Page 4: ...s to waterproof the screw holes Attach the keypad to the back cover Wiring cable Color Function Description Grey Black GND Negative pole Grey Alarm Alarm Negative Yellow Black OPEN2 Request to Exit Button of Zone 2 Yellow OPEN1 Request to Exit Button of Zone 1 Brown D_IN Door status detecting Red AC DC AC DC 12 24V power input Black AC DC AC DC 12 24V power input Blue Black NO 2 Black White COM2 G...

Page 5: ...tween 1101 1200 for Zone 2 The PIN is any 4 8 digits between 0000 99999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode To add a card user for Zone 1 To add a card User for Zone 2 1 Read Card 5 Read Card Cards can be added continuously without exiting programming mode To delete a PIN or a card user 2 User ID number for a PIN user or ...

Page 6: ...wer supply for magnetic lock Fail open power to lock Common power supply for lock release Fail secure power to unlock Common power supply for auto gate controller using Normally Open contact A C C E S S S E C U R I T Y P R O D U C T S L T D ...

Page 7: ...e Every time a valid fob card or Pin is read input in Toggle Mode the relay changes state and will not turn back until the fob card is presented or the PIN used Anti Tamper Alarm The KP KR16 uses an LDR light dependent resistor as an anti tamper alarm If the keypad is removed from the cover then the tamper alarm will operate Sound and LED indication Operation Status Red LED Green LED Blue LED Buzz...

Page 8: ...her Note When adding users if the Card or Pin user has been enrolled already you can not add it again The R3K will give a bleep as error Factory default setting Card or PIN mode To set users for Zone 1 3 1 2 To add PIN users 1 User ID number PIN The ID number is any number among 1 1100 The PIN is any 4 8 digits between 0000 99999999 with the exception of 1234 which is reserved Users can be added c...

Page 9: ...r Card quantity Card quantity is between 1 1100 Of the 8 digits card number it is the last 8 digits on the card To delete Card users by cards Note Users can be deleted continuously without exiting programming mode 2 Read Card The device can automatically identify the card of Zone 1 or Zone 2 To delete Card users by user ID This option can be used when a user has lost their card 2 User ID To delete...

Page 10: ... in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that this is done outside programming mode so the user can undertake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 2 Read Card or 2 User ID...

Page 11: ...tings Door Open Detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally but not closed after 1 minute the inside buzzer will bleep automatically to remind people to close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with an optional magne...

Page 12: ...signal can be set on or off When on the R3K will bleep when buttons are pressed when off the R3K will be in silent mode Normal status On 8 6 Factory default setting Acoustic signal Off 8 7 Change Zone 2 to Door Bell When no need to operate a second door Zone 2 can be set to operate the Door Bell The wiring is connecting the door bell to COM2 and NO2 Press the keypad will send the signal to the doo...

Page 13: ...d the button and power on release it after you hear two bleeps the LED will turn orange After 10 seconds it will turn red and bleep once to confirm factory default is successful Note Reset to factory default the user s card key fob information is still retained Delete all users Delete all users of Zone 1 Master Code 2 0000 Delete all users of Zone 2 Master Code 9 0000 A C C E S S S E C U R I T Y P...

Reviews: