![Acces I/O products PCI-DA12-2 User Manual Download Page 13](http://html1.mh-extra.com/html/acces-i-o-products/pci-da12-2/pci-da12-2_user-manual_3706267013.webp)
Manual PCI-DA12-2/4/6
13
Ground
Current Output (Jumpers placed in "I” Position)
DAC
Analog
Current Output
R
Load
Excitation Voltage
8-36 V maximum*
(Observe Polarity)
Ground
Voltage Output
DAC
Analog
Voltage O utput
R
Load
CARD
APPLICATION
5mA maximum
Figure 3-2
: Field Wiring
Caution!
Do not connect current loops in a DAC that is set to voltage mode. The loop supply can destroy
the DAC.