background image

 

ACCES I/O Products, Inc. 

858 550 9559 

www.ACCES.IO 

10623 Roselle Street 

800 326 1649 

http://acces.io/mPCIe-ISODIO-16

 

San Diego CA 92121-1506 USA 

[email protected] 

MADE IN THE USA 

ISOLATED

 

DIGITAL

 

INPUT

 

&

 

OUTPUT

 

 

B

OARD FOR 

M

INI 

PCI

 

E

XPRESS

 

H

ARDWARE 

M

ANUAL

 

M

ODEL 

 

 

M

PCI

E

-ISODIO-16

 

 

 

 

Summary of Contents for MPCIE-ISODIO-16

Page 1: ...9 www ACCES IO 10623 Roselle Street 800 326 1649 http acces io mPCIe ISODIO 16 San Diego CA 92121 1506 USA sales accesio com MADE IN THE USA ISOLATED DIGITAL INPUT OUTPUT BOARD FOR MINI PCI EXPRESS HARDWARE MANUAL MODEL MPCIE ISODIO 16 ...

Page 2: ...MM TO PANEL MOUNTABLE DB25F AVAILABLE INDUSTRIAL TEMP 40 C TO 85 C ROHS STANDARD ON BOARD 32 BIT TIMER WATCHDOG TO RESET BOARD TO DEFAULT POWER UP VALUES The mPCIe ISODIO 16 card is well suited to complex environments mitigating otherwise challenging ground loops high common mode and transient voltage spikes common in electrically noisy industrial or factory locations The mPCIe ISODIO 16 provides ...

Page 3: ... IN Isolated Input 2 IN 1 15 OUT 1 OUT Isolated Output 3 IN 2 16 OUT 2 ISOGND Isolated Ground 4 IN 3 17 OUT 3 VCCIO Fused Isolated 3 3VDC 0 05A 5 IN 4 18 OUT 4 N C No Connection 6 IN 5 19 OUT 5 Keep cumulative power draw from I O sourcing and VCCIO 50mA 7 IN 6 20 OUT 6 8 IN 7 21 OUT 7 9 N C 22 N C 10 N C 23 N C 11 ISOGND 24 N C 12 ISOGND 25 VCCIO 13 ISOGND Custom hardware interfaces can be produce...

Page 4: ...n nanoseconds to calculate the desired register divisor load value If the count value decrements to 0 the FPGA will stop petting the TPS3820 and it will after the 200ms time out period bark for 25ms resetting the FPGA Any write or read of any valid mPCIe ISODIO 16 register will reload the initial or new if it was a write to 30h 32 bit divisor value and the countdown process resumes After the TPS38...

Page 5: ...in compliance with RoHS and various other lead free initiatives WARNING A SINGLE STATIC DISCHARGE CAN DAMAGE YOUR CARD AND CAUSE PREMATURE FAILURE PLEASE FOLLOW ALL REASONABLE PRECAUTIONS TO PREVENT A STATIC DISCHARGE SUCH AS GROUNDING YOURSELF BY TOUCHING ANY GROUNDED SURFACE PRIOR TO TOUCHING THE CARD ALWAYS CONNECT AND DISCONNECT YOUR FIELD CABLING WITH THE COMPUTER POWER OFF ALWAYS TURN COMPUT...

Page 6: ...red and or replaced at ACCES option with no charge for labor or parts not excluded by warranty Warranty commences with equipment shipment FOLLOWING YEARS Throughout your equipment s lifetime ACCES stands ready to provide on site or in plant service at reasonable rates similar to those of other manufacturers in the industry EQUIPMENT NOT MANUFACTURED BY ACCES Equipment provided but not manufactured...