Chapter 4: Address Selection

  

The PCI architecture is Plug-and-Play. This means the BIOS or Operating System determines the 
resources assigned to PCI cards, rather than the user selecting these resources with switches or 
jumpers. As a result, the card’s base address cannot be changed, it can only be determined. It’s 
possible to use the Windows95/98/NT device manager to specify system resources but that method is 
beyond the scope of this manual. 
  
To determine the base address that has been assigned to the card, run the provided PCIFind.EXE 
utility program. This utility will display a list of all of the cards detected on the PCI bus, the addresses 
assigned to each function on each of the cards, and the respective IRQs and DMAs (if any) allotted.  
  
Alternately, some operating systems (Windows 95/98/2000) can be queried to determine which 
resources were assigned. In these operating systems, you can use either PCIFind or the Device 
Manager utility from the System Properties Applet of the control panel. These cards are installed in the 
Data Acquisition class of the Device Manager list. Selecting the card then clicking 

Properties

, then 

selecting the Resources Tab will display a list of the resources allocated to the card. 
  
The PCI bus supports a minimum of 64K of I/O space, your card’s address may be located anywhere in 
the 0400 to FFF8 hex range. PCIFind uses the Vendor ID and the Device ID to search for your card 
then reads the base address and IRQ assigned. If you want to determine the base address and IRQ 
assigned, use the following information: 

  
The Vendor ID code for the card is 494F (ASCII for “IO”). 
The Device ID code for the card is 10C9. 

 
 

Manual PCI-COM-1S 

12

Summary of Contents for LPCI-COM-1S

Page 1: ...ess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demo...

Page 2: ...10623 Roselle Street San Diego CA 92121 858 550 9559 FAX 858 550 7322 contactus accesio com www accesio com MODEL PCI COM 1S USER MANUAL FILE MPCI COM 1S Ca...

Page 3: ...thers IBM PC PC XT and PC AT are registered trademarks of the International Business Machines Corporation Printed in USA Copyright 1995 2005 by ACCES I O Products Inc 10623 Roselle Street San Diego CA...

Page 4: ...y warranty Warranty commences with equipment shipment Following Years Throughout your equipment s lifetime ACCES stands ready to provide on site or in plant service at reasonable rates similar to thos...

Page 5: ...Address Selection 12 Chapter 5 Programming 13 Initialization 14 Table 5 1 Baud Rate Divisor Values 14 Chapter 6 Connector Pin Assignments 17 Table 6 1 Connector Pin Assignments 17 Appendix A Applicati...

Page 6: ...biased please contact the factory COM Port Compatibility A 16550 UART is used as the Asynchronous Communication Element ACE It includes 16 byte transmit receive FIFO buffers to protect against lost d...

Page 7: ...yle connector compatible with RS422 and RS485 specifications Character length 5 6 7 or 8 bits Parity Even odd or none Stop Interval 1 1 5 or 2 bits Serial Data Rates Up to 115 200 baud Asynchronous Fa...

Page 8: ...TRANSCEIVER AUTO RTS CIRCUITRY OSCILLATOR PCI INTERFACE CHIP UART 16550 OR SIMILAR CO MPUTER PCI BUS DB9M Tx Rx Tx Rx RS485 MODE ONLY Tx Rx IRQ Figure 1 1 Block Diagram Manual PCI COM 1S 7...

Page 9: ...tallation The following instructions assume the CD ROM drive is drive D Please substitute the appropriate drive letter for your system as necessary DOS 1 Place the CD into your CD ROM drive 2 Type B t...

Page 10: ...uter cover and turn ON the computer Enter the CMOS setup program of your system and verify that the PCI plug and play option is set appropriately for your system Systems running Windows 95 98 2000 XP...

Page 11: ...85 operations where there are multiple terminals only the RS485 ports at each end of the network should have terminating resistors as described above Also for RS485 operation there must be a bias on t...

Page 12: ...TERMOUT 485 422 TERMIN X4 X1 4 80 1 80 Figure 3 1 Option Selection Map Manual PCI COM 1S 11...

Page 13: ...any allotted Alternately some operating systems Windows 95 98 2000 can be queried to determine which resources were assigned In these operating systems you can use either PCIFind or the Device Manager...

Page 14: ...nstalls into Windows as COM ports Thus the Windows standard API functions can be used In particular CreateFile and CloseHandle for opening and closing a port SetupComm SetCommTimeouts GetCommState and...

Page 15: ...4000 ft 1200 96 384 4000 ft Recommended maximum distances for differentially driven data cables RS422 or RS485 are for typical conditions Table 5 1 Baud Rate Divisor Values In C the code to set the ch...

Page 16: ...driven communications should be used whenever possible and is required for high data rates Writing an interrupt driven receiver is not much more complex than writing a polled receiver but care should...

Page 17: ...t is high the transmitter has sent the data The process of checking the bit until it goes high followed by a write is repeated until no data remains After all data has been transmitted the RTS bit sho...

Page 18: ...9 Rx Receive Data Table 6 1 Connector Pin Assignments Data Cable Wiring The following table shows pin connections between two devices for Simplex Half Duplex and Full Duplex operations Mode Card 1 Ca...

Page 19: ...ve Balanced Differential Signals The reason that RS422 and RS485 devices can drive longer lines with more noise immunity than RS232 devices is that a balanced differential drive method is used In a ba...

Page 20: ...characteristic impedance of the cable Note You do not have to add a terminator resistor to your cables when you use the card Termination resistors for the RX and RX lines are provided on the card and...

Page 21: ...that one node be a master node and all others be slaves The network is connected so that the master communicates to all slaves and all slaves communicate only with the master This has advantages in eq...

Page 22: ...give us some feedback please email us at manuals accesio com Please detail any errors you find and include your mailing address so that we can send you any manual updates 10623 Roselle Street San Dieg...

Page 23: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: