background image

5

D

IS
C

L

AI
M

ER

This Accella Tire Fill Systems Flatproofing Technical Manual contains information pertaining 
to flatproofing tires with our manufactured products that have been installed through Accella 
Tire Fill Systems approved processing systems. This Manual contains information regarding 
the flatproofing process only, it does not contain other information which may be relevant with 
respect to the flatproofing process (for example, the tire manufacturer’s specifications and 
information, workplace safety information, etc.). It is important that all flatproofing processors 
follow not only the safety procedures set forth in this Manual, but also standard safe operation 
and work conditions, and other safety procedures that may pertain to the facility in which the 
flatproofing is taking place, and the specific tire manufacturer’s safety information.

Although this Manual has been developed for the purpose of instruction, the flatproofing  
processor must be properly trained in all phases of the job performance, which include, without 
limitation, installing Accella Tire Fill Systems products into the tire in a safe manner, the proper 
use and operation of the equipment and the proper maintenance of such equipment.

Accella Tire Fill Systems shall not be responsible for any injury or damage to persons or property 
in connection with the processing or use of our products. Further, Accella Tire Fill Systems 
shall not be responsible for any injury or damage to persons or property due to a customer’s 
actions, the customer’s disregard for the safety procedures set forth in this Manual or other 
safety procedures, the customer’s failure to comply with the tire manufacturer’s product  
guidelines, or due to a customer’s failure to follow our instructions, verbal or written, pertaining 
to the flatproofing process.

Accella Tire Fill Systems technical and sales staff make routine visits to its customers’ locations 
for the purpose of reviewing processing locations. However, a customer should not rely on such 
visits as assurance that it has taken all safety and other precautions.

Accella Tire Fill Systems maintains a knowledgeable technical support staff who can assist our 
customers with any questions or assistance that may be needed in connection with our products. 
Further, Accella Tire Fill Systems maintains an inventory of parts, and written technical and 
safety data on its products.

Any questions regarding information contained in this Manual, our products, or our recommended 
equipment should be directed to the Accella Tire Fill Systems Sales and Technical Center at 
(800) 821-4147.

Summary of Contents for TyrFil Flushless Pump

Page 1: ...TyrFil Flushless Pump Flatproofing Technical Manual...

Page 2: ...e basic steps incorporated in the control air water valve procedure for filling a tire general troubleshooting if problems occur and general procedures for fixing the machine if problems occur If any...

Page 3: ...y Supplies 9 III Preparation Tire Wheel Preparation 10 Equipment Set Up 10 IV Tire Flatproofing Process Start Up Procedures 12 Processing 14 Tire Pressurization 17 Clean Up Procedures 17 V Pump Mainte...

Page 4: ...em into the tire replacing all of the air Pressurizing the tire to the recommended inflation pressure Curing at the proper time and temperature to ensure optimum filled tire performance It is a precis...

Page 5: ...ance of such equipment Accella Tire Fill Systems shall not be responsible for any injury or damage to persons or property in connection with the processing or use of our products Further Accella Tire...

Page 6: ...hless Pump Accella Tire Fill Systems original flatproofing pump was pioneered by Graco Inc in the early 1970s and has had many innovations since The Graco pump has an excellent performance reliability...

Page 7: ...oto 7b Hypodermic Needles Needles are used for venting tires during the filling process The standard size is 12 gauge 3 inch Other sizes are available For your convenience these are available from Acc...

Page 8: ...connect the air supply from the pump and close the release type ball valve on the air motor when servicing the air motor or cylinder displacement unit Spilled material must be cleaned promptly for eas...

Page 9: ...9b Industrial First Aid Kit Kits should be properly stocked and readily accessible for emergencies photo 9b Eye Protection Eye protection is essential and should be worn at all times as liquids pressu...

Page 10: ...roofing material A tire or wheel with a defect should not be used in flatproofing as it could result in a premature tire or wheel failure Allow time for drying if washing is required Tire contaminants...

Page 11: ...tool Two or three holes on each end is sufficient d Loosen top hose clamp on desiccant sleeve and insert desiccant container with inspection window facing forward and the arrow pointing down e Tighte...

Page 12: ...wing procedures when flatproofing tubeless tires for tires with tubes see the Miscellaneous Section Start Up Procedures 1 Remove manifold head mixer and fluid gun from the solvent container and wipe o...

Page 13: ...pumping material make certain manifold and dispensing valves are fully open Partially opening the valves can cause improper ratio of ISO and CAT side material 9 Make sure the 1000 psi cylinder pressu...

Page 14: ...ect the filling adapter to the tire valve stem Attach the filling adapter to the fluid gun 5 Fully open the valve on the manifold and begin filling the tire photo 14c 6 Check the internal tire pressur...

Page 15: ...tire being flatproofed the bead can collapse Should this occur the bead can be reseated using the Flushless Manifold while still attached to the tire s valve system 1 To reseat the bead turn off the m...

Page 16: ...disconnect the fluid gun and place over waste container 15 Lay filled tire on its side and place on a pallet Handle tires with tubes carefully as some tubes split easily Do not cure tires in an uprig...

Page 17: ...ter it is filled If leakage is observed the tire may need to be repressurized and resealed Repressurization Voids or air pockets are created when uncured material escapes from a newly flatproofed tire...

Page 18: ...ad from the hand valve photo 18c and wash manifold head in the solvent Open ball valve on the manifold and rinse the gauge port with solvent Store manifold head in the solvent when clean 8 Eject the m...

Page 19: ...ht plugs Wet Seal Cups During initial setup the wet seal cups should be filled 1 4 full with throat seal liquid TSL oil This oil provides critical lubrication to the piston rods and also serves as a m...

Page 20: ...will ensure that the tube will inflate properly Step 5 Remove the valve core and fill the tire as you normally would Step 6 When 30 50 of the final desired pressure has been reached insert the needle...

Page 21: ...ly inside the tire resulting in an overpressurized condition or possibly burst the tire casing causing injury Method 2 Mark the 12 o clock position on the tire and dismount it With the tube removed dr...

Page 22: ...ximately six to eight strokes 5 Continue Processing Begin processing as before using new material Although different types of TyrFil can be used without problem in the same equipment if you run out of...

Page 23: ...a Tire Fill Systems or one of its agents Below are some helpful hints for maintaining totes Storage Full Should be stored indoors and heated to 72 F 22 C before use Storage Empty All bungs and dust co...

Page 24: ...flush and alcohol must be kept in a closed drum labeled FLAMMABLE WASTE in an approved solvents storage area until delivered to a licensed disposer Salvaging Rims Flatproofed tires mounted on wheels w...

Page 25: ...NG THE TROUBLESHOOTING SECTIONS PROBLEM PROBABLE CAUSE SOLUTION 1 Identify the problem you are having from the list in this section Once you have lo cated your problem proceed to probable cause 2 Prob...

Page 26: ...Accella Tire Fill Systems approved sidewall injector Larger areas where the whole tire is affect ed will require dismounting cleaning and reprocessing b Check mixer Replace missing dirty or broken el...

Page 27: ...d hoses a Verify 80 psi 6 bar at regulator b This is normal Replace with a less restrictive valve if possible c Material must be 72 F 22 C d Replace fluid hoses Pump is operating and sud denly seems t...

Page 28: ...er or your technical representative before performing this test 1 Reduce the regulator setting to 40 psi 3 bar Open the ball valves on the ISO and CAT totes 2 Turn on the ball valve at the air motor 3...

Page 29: ...isture in your system but they are not by themselves 100 effective If you are still having problems after you have installed a water filter 2 Install a lubricator part number EQ L354 photo 26b be twee...

Page 30: ...800 821 4147 info accellatirefill com Visit www accellatirefill com for specs weight charts and more 2016 Accella Tire Fill Systems...

Reviews: