Accelerated Care Plus OMNISOUND 3000C PRO User Manual Download Page 10

 OMNISOUND

®

 3000C PRO USER MANUAL 

 

 7 

 COPYRIGHT © 2001 - 2017, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED

 

THE OMNISOUND

®

 3000C PRO 

Delivery of the Omnisound

®

  3000C Pro 

 

Upon  receipt  of  your

 

Omnisound

®

  3000C  Pro  inspect  the  shipping  container  and  contents  for  any  obvious  or 

concealed  damage.    All  ACP  products  are  packaged  carefully  for  rapid,  safe  delivery.    We  guarantee  delivery  in 
perfect condition to the postal or delivery services.  However, any damage or  loss incurred during transportation or 
delivery is  the  postal or Delivery  Company’s responsibility.  If damage  or loss to the  product  and/or container is 
obvious  or  suspected,  appropriate  notation  must  be  made  on  the  signed  freight  bill  at  the  time  of  delivery.    All 
damage claims should be promptly filed with the delivering carrier and must be initiated by the addressee where the 
package  was to be delivered.  Retain the original shipping container and inserts for validation of damage claim or 
use at a later date. 
 

NOTE:

  The purpose of this manual is to acquaint you with the Omnisound

®

 operating features and functions. 

In  order  to  avoid  any  misunderstanding,  please  read  the  manual  carefully  before  attempting  to  assemble  or 
operate the Omnisound

®

. If questions remain unanswered, contact your ACP sales representative or call 1-800-

350-1100 or internationally call 1-775-685-4000. 

Introduction 

 

Welcome  to  the  Omnisound

®

  3000C  Pro,  the  system  that  redefines  therapeutic  ultrasound.  While  conceiving  and 

designing  the  Omnisound

®

  3000C  Pro,  ACP  set  out  to  overcome  the  limitations  of  ordinary  ultrasound  devices.  

Here  are  just  a  few  of  the  functions  we  developed  that  make  the  Omnisound

®

  3000C  Pro  truly  the  future  of 

ultrasound therapy: 

 

Controlled  Depth  of  Penetration  - 

The  Omnisound

®

  3000C  Pro  enables  you  to  treat  soft  tissue  injuries, 

superficially  with  3  MHz  and  instantly  at  the  push  of  a  button,  treat  deeper  injuries  with  1  MHz  -  without 
switching transducers.

 

 

Two Transducer Sizes - 

Our 2cm

2

 and 5cm

2

 heads offer optimum flexibility in treatment and are automatically 

enabled as you change from one to the other. 

 

Fully Adjustable Transducer Head - 

A comfortable, consistent contact can be maintained during any surface 

or underwater application because the transducer head rotates to any degree angle from 0 to 360

0

 

Microprocessor  Controlled  Digital  Screen  - 

Easy-to-read  digital  screen  offers  accurate  indications  of  all 

treatment  parameters  plus  the  calibration  date,  assist  screens,  automatic  self-test,  Effective  Radiating  Area 
(ERA) and Beam Non-uniformed Ratio (BNR). 

 

Continuous and Pulsed Modes - 

Variable duty factors offer a choice between 5, 10, 20, 25, 33, 50 and 100% 

applications for optimum flexibility in all phases of treatment. 

 

Delta T Temperature Mode - 

Automatic dose control system helps to assure consistent tissue heating. 

 

Finger Tip Control - 

You no longer have to return to the ultrasound unit to alter output intensity. Just push the 

switch on the transducer. 

 

Combination  Therapy  - 

Interconnect  port  allows  combination  therapy  with  the  Omnistim

®

  family  of 

electrostimulators. 

 

Excellent  BNR  and  ERA  - 

Our  superior  BNR  and  ERA  makes  for  highly  uniform  and  comfortable 

applications. 

 

Over  Heating  Temperature  Sensing  Monitor  - 

A  coupling  monitor  indicates  when  the  transducer  head  is 

overheated and the power is shut down automatically. 

 

Automatic  Self-Test  with  Problem  Identification  - 

Allows  accurate  evaluation  and  documentation  of  unit 

functionality . . . before you begin treatment. 

Summary of Contents for OMNISOUND 3000C PRO

Page 1: ......

Page 2: ...not be used for any other purpose Any additional copies of the Manual shall be ordered from ACP No changes or modifications shall be made to the Manual without prior review and written authorization...

Page 3: ......

Page 4: ...Ultrasound Pulsed Shortwave Diathermy devices and advanced Therapeutic Exercise Systems Our MEGAPULSE NEUROPROBE OMNISTIM OMNISOUND OMNIBAND OMNITEST OMNICYCLE and OMNIVR represent the most recent wor...

Page 5: ...ocuments Caution electrical precautions Remote Control connection CE mark of confidence compliant to MDD 93 42 EEC Connection Electrode Cable IP2X Classification against intrusion of water dust accide...

Page 6: ...CIPLES OF USE 15 Definitions 15 Universal Precautions Body Substance Isolation 15 Cleaning Disinfecting of the Omnisound 3000C Pro 15 Cleaning and Low Level Disinfection 15 Intermediate Level Disinfec...

Page 7: ...crylate or high density polyethylene Arthroplasties the effect on bony ingrowth arthroplasties is not well defined for this reason the most prudent course is avoiding ultrasonic therapy over these are...

Page 8: ...or neck triangle including stellate ganglion vagus nerve or laryngeal or pharyngeal muscle Particular care should be taken for patients with a known sensitivity to the carotid sinus reflex as carotid...

Page 9: ...ontinue the treatment and shorten the treatment time on the next treatment session or use an alternative type of therapy or applicator placement Do not apply treatment directly over under hot or cold...

Page 10: ...at make the Omnisound 3000C Pro truly the future of ultrasound therapy Controlled Depth of Penetration The Omnisound 3000C Pro enables you to treat soft tissue injuries superficially with 3 MHz and in...

Page 11: ...FACTOR buttons are used to select the ultrasound output Continuous 100 for thermal applications Pulsed 5 10 20 25 33 or 50 for sub thermal applications NOTE Duty factor starts at continuous and goes...

Page 12: ...display in watts power or watts cm intensity Q The cooling fan provides airflow through the unit when the unit is operational R The ELECTROSTIM INPUT PORT is used to connect the shrouded pin to banan...

Page 13: ...off the system and connect the transducer to the Main output connector If both transducers are connected the main transducer will be selected 2 Omnisound 3000C Pro transducers contain their calibrati...

Page 14: ...rapidly if the output is switched ON and the transducer is not in contact with the skin Power Supply Operation Omnisound 3000C Pro is a line power only device It is not intended for use with batteries...

Page 15: ...ucers are fully waterproof and may be used with underwater techniques It is recommended that the handle is held by the operator without direct contact to the water to avoid exposure The Omnisound 3000...

Page 16: ...t a lower output is recommended Avoid using maximum power levels For example a typical comfortable output should be 0 5 1 0 W cm2 4 Apply coupling medium plentifully to the area to be treated As the s...

Page 17: ...s the active electrode Attach the self adhesive electrode to the patient s body Take the negative black tip pin and insert it into the shrouded pin to banana adapter Item No 2503036 Insert the adapter...

Page 18: ...inal secretions is likely to occur Health care workers with exudating lesions or weeping dermatitis should refrain from all direct patient care and from handling patient care equipment until the condi...

Page 19: ...creased risk of patient cross contamination After each use clean common contact surfaces such as control panel and ultrasound transducer with ACP germicidal wipes With a second ACP germicidal cloth wi...

Page 20: ...e Omnisound 3000C Prounit 4 Select and cut with clean scissors a 2 foot length of plastic sleeve and slide it over the ultrasound handle and cable 5 Apply ultrasound gel into plastic transducer cover...

Page 21: ...ing in pulsed or continuous modes at 1 0 MHz or 3 0 MHz for therapeutic applications Theory of Operation Ultrasonic therapy devices generally consist of a generator and a transducer The generator prod...

Page 22: ...ted that the effective radiating area does not generally cover the entire surface area of the transducer effective radiating surface and varies with the crystal frequency when operated at different cr...

Page 23: ...20 OMNISOUND 3000C PRO USER MANUAL COPYRIGHT 2001 2017 ACCELERATED CARE PLUS CORP ALL RIGHTS RESERVED...

Page 24: ...rally produce beams of perfectly uniform intensity over the surface of the transducer Thus the measurement represents an average for the effective radiating surface area Beam Divergence The beam diver...

Page 25: ...e BNR was 7 1 the maximum intensity in the tissue would equal 7 watts cm2 at certain portions of the field This should be kept in mind when determining output dosage It is also important to maintain c...

Page 26: ...inuous overheating of the transducer Ultrasound Transmission and Absorption When ultrasonic energy is applied to the tissue it is absorbed in varying degrees This absorption of energy can increase tis...

Page 27: ...supply adequate couplant apply the transducer to the patient and increase the power As you do so you will notice that the timer will change from 15 minutes to a lower value This will only occur if th...

Page 28: ...ity contact the Service Center TRANSDUCER NOT PRESENT message is displayed on the unit Transducer may not be connected properly Check if transducer is plugged in correctly If not plug in transducer an...

Page 29: ...andard 21 CFR 1050 10 instituted by the Food and Drug Administration Periodic calibration of treatment parameters having a direct influence on the physiological effect of ultrasound on tissue i e ultr...

Page 30: ...n Rate 20 20 1 1 100 continuous continuous 2 1 50 2 ms 250Hz 3 1 33 2 ms 165Hz 4 1 25 2 ms 125Hz 5 1 20 2 ms 100Hz 10 1 10 2 ms 50Hz 20 1 5 2 ms 25Hz ULTRASOUND APPLICATOR Piezoelectric Disk Lead zirc...

Page 31: ...t of the beam at 5mm from the transducer surface POWER AND INTENSITY Output Power 2cm2 5 cm2 1MHz 0 3W 0 12W Nominal 3MHz 0 3W 0 9W Nominal Output Intensity 1MHz 0 2W cm2 0 3W cm2 Nominal 3MHz 0 2W cm...

Page 32: ...T 2001 2017 ACCELERATED CARE PLUS CORP ALL RIGHTS RESERVED ACP ULTRASONIC THERAPY APPLICATOR INTENSITY IMAGE AT 5mm FROM TRANSDUCER SURFACE Model Number 3000C Pro Serial Number 2945 Frequency 1 or 3 M...

Page 33: ...3000C OMNISOUND 3000C PRO ULTRASOUND THERAPY SYSTEM 1 MHz and 3 MHz low BNR Ultrasound with Delta T dose control Shipping Weight 25 lbs 11 kg Standard Accessories ITEM ITEM NO DESCRIPTION 19856 AC Lin...

Page 34: ...ces Infection Control 6 x 9 perforated Sheets 1200 sheets roll 50593 Barrier Film for Surfaces Infection Control 12 x 14 perforated Sheets 800 sheets roll 63574 Barrier Tubing 3 x 004 High Clarity 1 2...

Page 35: ...ollowing have occurred 1 The product contains repairs or replacement parts not furnished by ACP 2 The product is damaged resulting from misuse or negligence 3 The product has been tampered with and or...

Page 36: ...warranty ACP is not responsible for any loss or damage to the Equipment prior to receipt at the ACP Service Center Equipment returned for warranty service must be shipped complete with all accessorie...

Page 37: ......