background image

Read all Warnings & Cautions before operating your  

FX Power Source 12 Power Supply 

 

1.   Keep these instructions – The safety and operating instructions should be retained for future  
       reference.  
2.   All warnings, cautions and instructions should be adhered too for safe operation of your FX   
      Power Source 12 power supply.

 

3.   Follow all operating and use instructions for safe operation of this unit.

 

4.   

WARNING!

!! 

This Power supply is designed to operate at 110-120V AC Only! Do not plug into                                               

 

a 220- 240V AC outlet!  Or risk of shock resulting in serious injury or death may occur. 

 

5.  

WARNING!!!

 The lightning flash with arrowhead symbol within an equilateral triangle is  

      intended to alert the user to the presence of non-insulated “dangerous voltage” within the  
      product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock.

 

6.

   WARNING!!!

 To reduce the risk of fire or electric shock, do not expose this power supply to rain  

      or moisture. The unit should not be exposed to liquids of any kind. Any objects or containers  
      filled with liquids, such as drinks or beverages shall not be placed on top of or near the unit.

 

7. 

  WARNING!!!

 If you are mounting into a surface thicker than .125"

 [3.18mm] or thicker a  

      longer screw may be required. Remember that Max protrusion depth into the power supply must    
      be  no more than .250" [6.35mm].  If this warning is not heeded, the presence of non-insulated  

  “dangerous voltage” within the product’s enclosure may be of sufficient magnitude to constitute a    
  risk of electric shock.

 

8.

   WARNING!!! 

Do not defeat the safety purpose of the grounding plug. A grounding plug has two  

      blades and a third grounding prong. The grounding prong is provided for your safety.

 

9.   

CAUTION!!!

 The exclamation with arrowhead symbol within a equilateral triangle is intended to  

       alert the users to the risk of damage to the FX Power Source 12 power supply if cautionary  
       instructions are not followed. 

10.

   

CAUTION!!!

 To prevent risk of overheating or damage to the FX Power Source 12 power  

        supply. 

Do Not Block any ventilation openings! 

The ventilation should not be impeded by  

        covering the ventilation openings with items such as, tape, fabric, Velcro or any potentially  
        flammable material. 

11.   

CAUTION!!!

 To prevent risk of overheating or damage to the Power Source 12 power supply.   

        Mount per the FX Power Source 12 Mounting Instructions! 

 

12.

   Clean only with a dry cloth.

 

13.

   Do not install near any heat sources that produce heat.

 

14.

   Protect the power cord from being walked on or pinched. Especially near the plugs, convenience  

        receptacles, and at the point where they exit from the unit.

 

15. 

  Follow all instructions and recommendations regarding attachments/ accessories specified by the  

        manufacturer.

 

16. 

  Only use this unit as prescribed and specified by the manufacturer to power effects pedals.

 

17.

   Unplug the unit during lightning storms or when unused for long periods of time.

 

18.

   Refer all servicing to qualified personnel. Service is required when the power supply has been  

        damaged in any way – such as power supply cord or plugs damage; if any liquid or foreign  
        objects have gotten inside the unit; if it has been exposed to rain or moisture; has been dropped;  
        or does not otherwise operate  normally. 

19. 

 Caution: Do not plug devices (such as effects pedals) in until you have verified the applicable   

       output is rated for the matching  voltage of your device or set to the correct voltage of  
       your device. If you do not set the correct voltage to match the voltage on your device damage  
       may  occur to your device.

 

 

Summary of Contents for FX POWER SOURCE 12

Page 1: ...USER S MANUAL ...

Page 2: ...d to power outputs 9 12 Each of the 12 outputs are fully isolated regulated and filtered with over voltage protection The all aluminum anodized enclosure dissipates the heat rapidly and keeps components within proper operating temperature Our FX Power Source 12 mounts conveniently currently onto our Accel XTA21 pedal boards with only three M4 mounting screws supplied The FX Power Source 12 powers ...

Page 3: ...s When output 12 is switched to 18V this output is designed to provide power to 18V pedals that require 250mA or less Low Battery Simulation option Output 2 can be adjusted from 9V down to 5V to be used to simulate a low battery which comes in handy if you have older transistor based distortion and fuzz pedals Negative center polarity positive center polarity barrel jacks Most pedals on the market...

Page 4: ... prong is provided for your safety 9 CAUTION The exclamation with arrowhead symbol within a equilateral triangle is intended to alert the users to the risk of damage to the FX Power Source 12 power supply if cautionary instructions are not followed 10 CAUTION To prevent risk of overheating or damage to the FX Power Source 12 power supply Do Not Block any ventilation openings The ventilation should...

Page 5: ...tputs 7 Output 12 High Current Switchable Output 9V 12V 18V 4 100 120V AC INPUT WARNING TO PREVENT RISK OF ELECTRICAL SHOCK DO NOT OPEN NO USER SERVICEABLE COMPONENTS INSIDE REFER TO QUALIFIED SERVICE PERSONNEL 1 50mA 100mA 100mA 250mA 5 9V 8 9V 4 7 6 5 3 2 1 9V L R 12V 9V L R 12V 9V L R 12V 9V L R 18V 100mA 100mA 100mA 250mA FX Power Source 12 12 ISOLATED AND REGULATED DC OUTPUTS 300mA 9 10 11 12...

Page 6: ... rated for the matching voltage of your device or set to the correct voltage of your device 10 Air Vents 5 8 7 6 5 3 2 1 4 7V 9V 5V DO NOT BLOCK POWER SUPPLY VENTS CAUTION UNPLUG EFFECTS PEDAL BEFORE ADJUSTING OR SWITCHING VOLTAGE 9 10 11 12 8 12 PLACES 9 12 PLACES 10 10 100 120V AC INPUT WARNING TO PREVENT RISK OF ELECTRICAL SHOCK DO NOT OPEN NO USER SERVICEABLE COMPONENTS INSIDE REFER TO QUALIFI...

Page 7: ...unting 6 11 11 11 11 11 POWER SUPPLY MOUNTING HOLES ALTERNATE MOUNTING USING 3M DUAL LOCK STRIPS 3M DUAL LOCK was designed as an alternative to hardware mounting Once locked in place You will either need to pry the power supply out at an angle with strong hands or a pry type tool unless you are a gorilla 12 12 ...

Page 8: ...T 100 120V 394 10 9V R C L 18V 12V 9V 9V 9V 3 390 86 8 664 220 1 772 45 7 770 197 4 9V 9V 300mA 550mA 400mA 12 11 10 9 300mA 12 ISOLATED AND REGULATED DC OUTPUTS FX Power Source 12 4 884 124 1 1 299 33 400 10 2 POWER SUPPLY MOUNTING HOLES M4 THREADS 5 PLACES 250mA 100mA 100mA 100mA 18V R L 9V 12V R L 9V 12V R L 9V 12V R L 9V 1 2 3 5 6 7 4 9V 8 5 9V 250mA 100mA 100mA 50mA ...

Page 9: ... an output 1 As long as combined effects pedals current of outputs 1 6 do not exceed 300 mA then outputs 7 and 8 can provide up to 350mA s each 2 As long as combined effects pedals current of outputs 11 12 do not exceed 800mA s then outputs 9 10 can provide up to 350mA s each 3 As long as combined effects pedals current of outputs 9 10 12 do not exceed 1000mA s then output 11 can provide up to 500...

Page 10: ...u are mounting into a surface thicker than 125 3 18mm or thicker a longer screw may be required Remember that Max protrusion depth into the power supply must be no more than 250 6 35mm Do not drill into power supply If these warnings are not heeded electrical shock or death may occur Caution Do not do not block air vents Do not mount in an area where no air circulation is present Do not mount in a...

Page 11: ...ranty you must retain proof of purchase If something goes wrong with your Accel Power Source 12 power supply send a brief description of the problem to support accelaudio com This warranty gives you specific legal rights and you may also have other rights which vary from state to state Accel Technologies LLC Email support accelaudio com 10 ALTERNATE MOUNTING USING 3M DUAL LOCK STRIPS 3M DUAL LOCK ...

Reviews: