Acceed IP101 Installation Manual And User'S Manual Download Page 8

7.  When the 

Maintenance Complete

 window comes up, click 

Finish

 to complete the maintenance. 

 

2.2.2  Installing Virtual COM 

 

1.  Click on 

Start -> Programs -> COMPANY NAME -> IP SERVER DEVICE -> Install Virtual COM.

 

2.  The first window indicates installation program search IP SERIAL SERVER servers connected to the network. 
3.  The  next  window  lists  all  servers  connected  to  the  network,  as  well  as  their  server  name,  IP  address, TCP  port, 

flow control mode and if they are mapped to any virtual COM. 

4.  Select a server, then click 

OK

5.  If the server is already mapped to a virtual COM, a message 

The server is already mapped! 

pops up, click 

OK

 

go to step 3. 

6.  If you don’t select any server, then click 

OK

, the default parameters are used. 

7.  The  next  window  show  the  server’s  parameters  or  default  parameters    such  as  IP  address,  TCP  port  and  flow 

control mode.  

8.  Choose a COM port number from the pull down list and click 

OK

 to continue. 

9.  A progress window shows the installation, when this window disappears, the virtual COM is installed. 

 

2.2.3  Using IP SERIAL SERVER Manager 

 

IP SERIAL SERVER Manager includes the following utilities: Firmware Upgrade, Virtual COM Configuration, Searching 
IP SERIAL SERVER, and Uninstall Virtual COM. To start IP SERIAL SERVER Manager, click on 

Start

 -> 

Programs -> 

COMPANY NAME -> IP SERVER DEVICE -> IP SERVER DEVICE Manager.

 

Switch between Virtual COM list and IP SERIAL SERVER server list 
Click the 

Virtual COM Configuration

 icon, the right panel lists all installed virtual COM ports from the last configuration. 

Click  the 

Searching  IP  SERIAL  SERVER

  icon,  the  right  panel  lists  all  servers  connected  to  the  network  from  the  last 

searching. 

2.2.3.1 

Firmware Upgrade 

1.  Click  on 

Firmware  Upgrade

  from  the  IP  SERIAL  SERVER  pull  down  menu  or  double  click  the 

Firmware 

Upgrade

 icon. 

2.  In the 

Upgrade

 window, click 

Browse...

 to locate the upgrade file, and choose a COM port from pull down list, 

then click 

Upgrade

3.  If  you  choose  an  IP  SERIAL  SERVER’s  virtual  COM,  a  progress  window  shows  up  to  indicate  the  upgrade 

progress. 

4.  If  you  choose  a  COM  port  other  than  IP  SERIAL  SERVER’s  virtual  COM,  the  next  window  shows  the  port 

settings, make sure these settings match with IP SERIAL SERVER server’s, then click 

OK

5.  When the progress window disappears, a message 

Upgrade finished!

 pops up, click 

OK

 to return. 

2.2.3.2 

Virtual COM Configuration 

1.  Click  on 

Virtual  COM  Configuration

  from  the  IP  SERIAL  SERVER  pull  down  menu  or  double  click  the 

Virtual COM Configuration

 icon. 

2.  The  right  panel  lists  all  installed  virtual  COM  ports,  as  well  as  their  COM  name,  IP  address,  TCP  port,  flow 

control mode and status. 

3.  Double click on any virtual COM will bring up its configuration window. 
4.  Make changes on 

Map To

IP Address

TCP Port

Flow Control,

 as you want, then click 

OK

5.  A message 

Configuration finished!

 pops up, click 

OK

 to return. 

2.2.3.3 

Searching IP SERIAL SERVER 

1.  Click on 

Searching  IP  SERIAL  SERVER

 from the IP SERIAL SERVER pull down  menu or double click the 

Searching IP SERIAL SERVER

 icon. 

2.  After searching, the right panel lists all servers connected to the network, as well as their server name, IP address, 

TCP port, mapped to any virtual COM or not, and status. 

3.  Double  click  on  any  server,  if  a  password  is  set  for  the  server,  a  password  window  will  display  first  to  ask  for 

permission, then bring up the properties window which displays the mutual properties such as server name, serial 
number and IP address on the left, while the properties for each port such as port number, protocol and baud rate 
are displayed on the right.  

4.  To change the server properties, input new value in each field, then click 

Update

. The new settings will take effect 

after restarting the device. If the server has more than one ports, select a different port from 

Serial port

 pull down 

list, its properties are displayed accordingly. 

2.2.3.4 

Uninstall Virtual COM 

1.  First select a virtual COM on the right panel when it displays installed virtual COM ports. 
2.  Click on 

Uninstall  Virtual  COM

 from the IP SERIAL SERVER pull down menu or double click the 

Uninstall 

Virtual COM

 icon. 

Summary of Contents for IP101

Page 1: ...IP SERIAL DEVICE SERVER Installation guide And User manual Version 1 0...

Page 2: ......

Page 3: ...2 1 Installing Driver and Software 3 2 2 2 Installing Virtual COM 4 2 2 3 Using IP SERIAL SERVER Manager 4 2 3 Windows 98 ME 5 2 3 1 Installing Driver and Software 5 2 3 2 Installing Virtual COM 5 2 3...

Page 4: ...0...

Page 5: ...is a virtual COM port that convert application s data into IP packet IP SERIAL SERVER then converts the IP packet back to serial data In this mode IP SERIAL SERVER must set to either TCP server or UD...

Page 6: ...on t select any server then click OK the default parameters are used 7 The next window show the server s parameters or default parameters such as IP address TCP port and flow control mode 8 Choose a C...

Page 7: ...ext window shows uninstalling progress when it disappears the virtual COM is uninstalled 2 1 4 Configuring Virtual COM using Device Manager There are two ways to configure virtual COM The first method...

Page 8: ...SERIAL SERVER s virtual COM a progress window shows up to indicate the upgrade progress 4 If you choose a COM port other than IP SERIAL SERVER s virtual COM the next window shows the port settings mak...

Page 9: ...to a virtual COM a message The server is already mapped pops up click OK go to step 3 6 If you don t select any server then click OK the default parameters are used 7 The next window show the server s...

Page 10: ...l port pull down list its properties are displayed accordingly 2 3 3 4 Uninstall Virtual COM To uninstall virtual COM port on Windows 98 you will be asked to use device manager to do that 1 First sele...

Page 11: ...l interface is RS422 3 2 Configuring IP SERIAL SERVER There are three ways to configure IP SERIAL SERVER one as described in the Search IP SERIAL SERVER section After IP SERIAL SERVER manager find the...

Page 12: ...ine The first field selects TCP or UDP protocols The second field chooses the port number of the connection A predefined TCP port 5300 is reserved for the heartbeat When using UDP protocol there is no...

Page 13: ...tion Next you open your saved Hyperterminal connection everything will be fine Q What should I do when I forget the IP address or baud rate setting of an IP SERIAL SERVER A You can use the default set...

Page 14: ...subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received Including interference that may cause undesired operation...

Page 15: ......

Page 16: ......

Page 17: ...BMNT12400A00...