Specifications
Power
Input Power Rating
AC Input: 100-240Vrms, 2.5-1.0A, 80 Plus Platinum
DC Input: Vdc=36-72VDC, 6.5-3.25A, Efficiency 80%
(Min)@48V
Power Consumption
150W
Nom
, 230W
Max
Optical Port Power Rating
QSFP: 5.0W(Max) Per Port
SFP+: 2.0W(Max) Per Port
Physical
Dimensions (W x H x D)
426.6 x 44.2 x 351.3 mm (16.8 x 1.74 x 13.83 in)
Weight
6.5kg (14.3lbs)
Environmental
Operating Temperature
0C to 50C
Storage Temperature
-40C to 70C
Operating Humidity
5% to 85% RH, Non Condensing
Storage Humidity
5% to 95% RH, Non Condensing
Maximum Altitude
2000 m, Above Sea Level
Regulation & Standard Compliance
(Unique ID: NG100 )
Safety
IEC 62368-1, EN 62368-1, UL 62368-1, CSA C22.2 No.
62368-1, AS/NZS 62368.1, J62368-1, CEI EN 62368-1,
DS/EN 62368-1, SASO-IEC-62368-1
EMC - Emission (Class A)
CISPR 32, IEC 61000-3-2, IEC 61000-3-3, EN 55032,
EN 61000-3-2, EN 61000-3-3, 47 CFR Part 15 Sub-
part B, ICES-003, AS/NZS CISPR 32, VCCI-CISPR 32,
KS C 9832
EMC - Immunity
CISPR 35, EN 55035, KS C 9835
Telco
NEBS Level-3: GR-63, GR-1089
Radio
ETSI EN 301 489-19, ETSI EN 303 413
Enviro
RoHS: IEC 63000:2016,EN IEC 63000:2018
Compliance Statements
423-047-00, Revision 8
Published: 2022-12-16
FCC Class A
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio com
-
munications. Operation of this equipment in a residential area is likely to cause harmful interfer
-
ence in which case the user will be required to correct the interference at his own expense.
VCCI–A
Note:
Package can contain other ordering options. See ordering guide for more details.
KCC-A
Attention:
This product, like all electronic products, uses semiconductors that
can be damaged by electrostatic discharge (ESD). Always observe appropriate
precautions when handling.
Warning:
Potential for damage to equipment or personal injury.
Conventions
Attention:
This symbol indicates that the surface is hot and to use caution to avoid
touching it.
Protective grounding point
この装置は、クラスA情報技術装置です。この装置を家庭環境で使用すると電
波妨害を引き起こすことがあります。この場合には使用者が適切な対策を講ずる
よう要求されることがあります。
사용자 안내문
이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 가
정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다.
Do not place hands, fingers or foreign objects in any holes, insertion slots or gaps.
To avoid damage to the equipment, keep objects clear of system ventilation inlets,
outlets and system fans, if any, ensuring the air flow through the units is not
obstructed, and that the fans rotate freely.
Do not disassemble or alter the unit.
Package Contents
Basic Contents
–
Skylight Flex 100 (1)
–
This Hardware Installation Guide (1)
–
19" Bracket kit
Power Supply Airflow Outtake Air is exhausted through the back of the power supply
Ground Lug
Unit Protective Ground Point
System Fans
Fans 1, 2, 3 & 4 locations
Back Panel
Unit Description
Skylight Flex 100™
HARDWARE INSTALLATION GUIDE
The intra-building ports of the equipment or subassembly is suitable for
connection to intra-building or unexposed wiring or cabling only. The intra-
building ports of the equipment MUST NOT be metallically connected to
interfaces that connect to the OSP or its wiring.