⑦
Backup LED indicator
⑧
Backup to CF button, push this button to trigger an immediately backup and overwrite the
data in CF card. (refer to restore and backup procedures for detail operation)
ANS-9010 restore and backup procedures
Condition Check
Functioning in ANS-9010
CF exist CF capacity >= RAM Size
Yes
Yes
Auto
No
No
N/A
Yes
Yes
Manual
Yes
Yes
Auto
No
No
N/A
SATA
Power
Working
Type
Power
On
ANS-9010 will take the total memory size as RAM disk size.
Also it will auto restore data from CF to RAM if it has been
successfully backuped
ANS-9010 will take the total memory size as RAM disk size.
Restore and backup function will be disabled
ANS-9010 will take the total memory size as RAM disk size.
Restore and backup function will be disabled
In some cases, we have to force data restore from new
inserted CF to memory, push the restore button for 3
seconds as soon as the CF was detected and the restore
LED is in status of steady green (5 seconds only). And
ANS-9010 will take the total memory size as RAM disk size
and start to copy data from CF to memory.
On the other hand, if we want to manually backup data from
RAM to CF, push the backup button for 3 seconds when the
backup LED is in status of steady green. And ANS-9010 will
start to backup data from RAM to CF.
Power
lost
When the SATA power lost over 30 seconds, ANS-9010 will
automatically backup data from memories to CF and power
off
ANS-9010 will keep data refresh in memories until running
out of power. When the power is running out, the data will be
lost.
ANS-9010 will keep data refresh in memories until running
out of power. When the power is running out, the data will be
lost.
LED Status
Description
Steady Red
CF card is too small or damaged to backup
Steady Green
CF card is ready to backup; Backup progress is complete
Blinking Green
CF card is under backup
Blinking Green per 4 seconds Backup progress is under 30%
Blinking Green per 2 seconds Backup progress is between 30%~60%
Blinking Green per 1 second
Backup progress is over 60%
OFF
No CF card inserted