JetStor SAS 742JD
44
User Manual
1.
Please use the RS232 cable (RJ11 to DB9) to JBOD Controller #1 and to connect
JBOD RS232 Port and PC COM1 Port (or change to other COM Port as necessary).
2.
Open Windows HyperTerminal Program. Connect using COM1 (COM Port used in
Step1), Baud Rate: 115200, n, 8, 1, Flow Control: None.
3.
Press the Enter key and the password prompt will be displayed.
4.
Key in the password (Default password: 00000000) to login to CLI.
5.
At CLI prompt, input the command to update firmware.
a.
CLI> mo
Operation Mode: Redundant, I2C Master, CLI DUAL
Operation Mode: Redundant, I2C Backup
NOTE: If Operation Mode is “Redundant, I2C Master, CLI Dual”, it
means you are connected to Master Expander and you can
continue with next steps. If Operation Mode is “Redundant, I2C
Backup”, it means you are connected to Backup Expander. Remove
RS232 serial cable and insert to other JBOD RS232 Port.
b.
CLI> mo fdl both
c.
CLI> mo
Operation Mode: Redundant, I2C Master, fdl both
d.
CLI>
NOTE:
“fdl code” is the command to update flash firmware code (.fw
file).
“fdl mfgb” is the command to update CFG data code (.rom file)
Make sure you have both files before updating.
e.
CLI> fdl mfgb
Please Use XModem Protocol for File Transmission.
Use Q or q to quit Download before starting XModem.
Offset = 0x0
f.
Select Function menu to transfer CFG data .rom file: “Function”
“Transfer”
“Send File”
“Browse”
“Open” and select the .rom file
(for example: 8016-mfgdat6-20110131.rom) firmware folder location.
Select “XModem” Protocol to send firmware file (Only need about 60
seconds to finish sending firmware file. If not, please repeat steps
B and D again).
Note. If won’t to transfer CFG data .rom file, Press Q or q to quit Download
before starting data transfer.