background image

Weighing Only Mode Setting [ 

NoDE_1

 ]

1. The default Weighing Only Mode Setting is set to ON, which means this mode is enabled.

 • ON: The Weighing Mode is enabled.

 • OFF: The Weighing Mode is disabled. 

Dual Display Mode Setting [ 

NodE_2

 ] 

1. By default, the Dual Display Mode Setting is set to ON, which means this mode is enabled.

 • ON: The Dual Display Mode is enabled.

 • OFF: The Dual Display Mode is disabled.

Timer Starts with Flow Mode     Setting [ 

NodE_3

 ]

1. By default, the Timer Starts with Flow Mode with Droplet Setting is set to ON, which means this 

mode is enabled.

 • ON: The Timer Starts with Flow Mode with Droplet is enabled.

 • OFF: The Timer Starts with Flow Mode with Droplet is disabled.

Auto-Tare Timer Starts with Flow Mode         Setting [ 

NodE_4

 ]

1. The default Auto-Tare Timer Starts with Flow Mode with Droplet and Square Setting is set to 

ON, which means this mode is enabled.

    • ON: The Auto-Tare Timer Starts with Flow Mode with Droplet and Square is enabled.

    • OFF: The Auto-Tare Timer Starts with Flow Mode with Droplet and Square is disabled.

Auto-Tare Auto-Start Timer Mode         Setting [ 

NodE_5

 ]

1. 

The default Auto-Tare Auto-Start Timer Mode with Triangle and Square Setting is set to ON, 

which means this mode is enabled.

    

• ON: The Auto-Tare Auto-Start Timer Mode with Triangle and Square is enabled.

    

• OFF: The Auto-Tare Auto-Start Timer Mode with Triangle and Square is disabled.

Auto-Tare Mode      Setting [ 

NodE_6

 ]

1. 

The default Auto-Tare Mode with Square is set to ON, which means this mode is enabled.

    

• ON: The Auto-Tare Mode with Square is enabled.

    

• OFF: The Auto-Tare Mode with Square is disabled.

Bluetooth Setup Setting [ 

bt_SEt

 ]  

1. OFF: Bluetooth is disabled. The scale does not allow any Bluetooth connection.

2. ON: Bluetooth is enabled. The scale allows Bluetooth connection. The user may connect the 

scale with Acaia apps.

Battery Saving [ 

bAttSAvE

 ] 

1. Save up to 20% of your battery by dimming the display after some time. It will return to its origi-

nal brightness when the scale detects objects on it.

2. The number indicates the amount of time before the scale enters battery saving mode.

3. Tap the tare button to toggle through the options.

Pre-Infusion Time Out [ 

PrE_inFu

 ] 

1. Determines when the scale times out in all three of the Auto-Start modes. This is most useful 

for long pre-infusion times and resolves the timeout that sometimes happens for slow pre-infusion 

times.

2. The number indicates the time in seconds it will take for the scale to reset if no espresso flow or 

weight is detected.

14

Summary of Contents for lunar

Page 1: ...Acaia Lunar User Manual FW 2 6 005...

Page 2: ...n Mode Introduction Mode 1 Weighing Mode Mode 2 Dual Display Mode Mode 3 Timer Starts with Flow Mode Mode 4 Auto Tare Timer Starts with Flow Mode Mode 5 Auto Tare Auto Start Timer Mode Mode 6 Auto Tar...

Page 3: ...injury or physical damage Thank you for choosing our scale The Acaia Lunar is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience Start by checking...

Page 4: ...that is stable vibration free and if possible a horizontal location for the weighing platform 4 Press to turn on the scale Double tap to turn off the scale Short press to tare zero the weight Press a...

Page 5: ...a week Battery percentage can be viewed via the Acaia apps Note Using a fast charging charging block or charging hub a charging block hub delivering over 5v at 1A could damage your Acaia scale s circu...

Page 6: ...Display Mode gram and ounce When the scale is measuring in grams the LED display shows 0 00 0 0 When the scale is measuring in ounces the LED display shows 0 00 0 00 If the weight exceeds 2000 00 gram...

Page 7: ...he timer will stop when flow is no longer detected Switch Mode Press and hold Power button When the scale detects the flow of espresso the timer starts The timer will stop when the flow stops Please n...

Page 8: ...00 to 9 59 and then stops Display Mode Description This mode is designed for baristas who would like to measure the time of the shot starting from the first few drops of espresso When a stable weight...

Page 9: ...Stop Reset Timer The timer will start when a stable weight is placed on the scale Tare Weight Tare function starts when a stable weight is placed on the scale Reset Mode Double tap Tare button Stop Ti...

Page 10: ...d Pull the shot of espresso as usual When the cup is removed from the scale the display flashes the final beverage weight and also shows In this mode the scale will only per form auto tare without aut...

Page 11: ...espresso flow stops 2 In all Auto Start Modes if you do not operate the scale for 30 seconds it will reset timer and perform tare operation 3 In all Auto Start Modes the timer will stop when a negati...

Page 12: ...ns Default Sleep Timer SLEEP 5 10 20 30 60 Off 5 Zero Tracking trAcE 0 5 d 1 d 2 d 3 d Off 1 d Key Sound bEEP On Off On Zero Range O rAnGE 2 100 100 Weighing Filter Filt 2 4 6 8 16 32 64 128 16 Defaul...

Page 13: ...hat lies outside the range is tared out by tare operation 3 If Zero Range is set to 100 the range for zero setting will be 100 of the capacity i e 2 kg for Acaia Lunar Therefore instead of tare operat...

Page 14: ...nd Square Setting is set to ON which means this mode is enabled ON The Auto Tare Auto Start Timer Mode with Triangle and Square is enabled OFF The Auto Tare Auto Start Timer Mode with Triangle and Squ...

Page 15: ...ivity but is recommended only for stable working environments Auto Reset Auto_rES 1 After a cup is removed the timer will automatically reset This gives you options on how long to wait for the reset T...

Page 16: ...er Back While in Settings Menu tap to go back to Modes Tare Button Tare Tap to perform tare operation Tare and reset timer While in Auto Start Modes double tap to zero weight and reset timer Switch op...

Page 17: ...th Flow Droplet When the scale detects the flow of espresso the timer starts The timer will stop when the flow stops Please note The flow detection mode is designed to detect the flow of espresso The...

Page 18: ...he weight is over the maximum capacity Under load the weight is under the minimum capacity 304 Calibration error Calibration cannot proceed when environmental noises are too strong Please calibrate in...

Page 19: ...lity 0 1 g Linearity 1 d d 0 1 g Indication Limit 2060 g 72 66 oz Power Supply 5 V 500 mA Battery Lithium ion rechargeable 3 7 V 1100 mAh Battery Life Up to 27 hours Display LED Material Aluminum Acry...

Page 20: ...l rights reserved No part of this manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means with...

Reviews: