•  There are two different weighing units in Beverage Mode: gram and ounce.

•  As soon as the weight is stabilized or the tare button is pressed, the next step will show in  

    the display.“---” indicates the scale is performing auto-tare.

•  AFTER the process is completed and the filter is removed, the display will blink and flash   

    the time elapsed for the brew, total amount of water added, beverage weight in the carafe,  

    and the coffee-to-beverage ratio at the end of the brew.

Mode 5 - Beverage Mode

Action

Operation

Tare Weight

Tap Tare button

Next Step

Press and hold Tare button

Previous Step

Press and hold Power button between the steps

Stop Timer

Tap Power button

Reset Mode 

Double tap Tare button

Switch Mode

Press and hold Power button

Display

Action / Description

Put the carafe/cup on the scale, press and hold the Tare button to 

go to the next step.
Put the filter/dripper on the carafe/cup, press and hold the Tare 

button to save the dripper weight.
Measure the amount of coffee beans you want to use. When 

you’ve reached the target coffee bean weight, press and hold the 

Tare button to save the weight.
The timer starts when water pour is detected. The timer stops 

when you tap the Power button or remove the filter/dripper.

Remove the filter/dripper to proceed.

After the filter/dripper has been removed, the scale will display 

the final time and weight, the beverage weight, and the coffee-to-

beverage ratio.

9

This mode is designed to measure the coffee-to-beverage 

ratio. It is one of the most consistent methods for measuring 

pour over extraction. With this mode, you will be able to see 

the time elapsed for the brew, total amount of water added, 

beverage weight in the carafe, and the coffee-to-beverage 

ratio at the end of the brew. 

Summary of Contents for AP009

Page 1: ...Acaia Pearl User Manual FW 1 0 010 AP007 AP008 AP009...

Page 2: ...e Battery Indicator Calibration Flow Rate Indicator Mode Introduction Mode 1 Weighing Only Mode Mode 2 Dual Display Mode Mode 3 Pour Over Auto Start Timer Mode Mode 4 Portafilter Mode Mode 5 Beverage...

Page 3: ...in personal injury or physical damage Thank you for choosing one of our scales The Acaia Pearl is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience...

Page 4: ...Modes Toggle Units Place the scale on a stable and vibration free surface at a preferably horizontal location 4 Press to turn on the scale Double tap to turn off the scale Tap to tare zero the weight...

Page 5: ...e has cooled Turn on the Acaia scale Make sure the scale is in Weighing Only Mode and the unit is set to gram then tap the T button rapidly Keep tapping the T button until CAL is shown on the display...

Page 6: ...5 g per second the last three LEDs will light up with enhanced brightness indicating a high flow rate To provide thresholds for ideal flow rates the first pair of the brighter LEDs represents 2 5 g p...

Page 7: ...ress and hold Tare button Reset Mode Double tap Tare button Switch Mode Press and hold Power button In the Dual Display Mode the scale displays 0 00 0 0 with a timer left and weight right There are tw...

Page 8: ...e weight In grams the LED display shows 0 00 0 0 with the timer on the left and the weight on the right In ounces the LED display shows 0 00 0 00 with the timer on the left and the weight on the right...

Page 9: ...e carafe cup on the scale press and hold the Tare button to go to the next step Put the filter dripper on the carafe cup press and hold the Tare button to save the dripper weight Measure the amount of...

Page 10: ...tness Setting bright 1 2 3 4 2 Battery Saving Setting bAttSAvE 30 90 180 Off 90 Zero Tracking Setting trAcE 0 5 d 1 d 2 d 3 d Off 2 d Key Sound Setting bEEP On Off On Weighing Filter Setting FiLtEr Fa...

Page 11: ...f the scale Acaia Pearl is allowed to compensate fluctuations of up to 3 d according to the industrial weighing guidelines 3 Off It is not recommended to turn off Zero Tracking as the zero indication...

Page 12: ...ng Only Mode Setting NodE_1 1 The default setting is On 2 On Mode enabled 3 Off Mode disabled Dual Display Mode Setting NodE_2 1 The default setting is On 2 On Mode enabled 3 Off Mode disabled Pour Ov...

Page 13: ...20 seconds 2 In Pour Over Auto Start Timer Mode after a cup is removed the timer and weight will automatically reset This setting gives you options on how long to wait before resetting 3 If this setti...

Page 14: ...p to go back to Weighing Only Mode Tare Tap to perform tare operation Toggle Units Press and hold to switch between gram and ounce Reset Mode Double tap to reset a mode This zeroes the weight and sets...

Page 15: ...uto tare when a stable weight is placed on the weighing pan LED Indicators Power Button Tare Button 15 Charging Low Battery Indicator This indicator turns on when the battery is charging and turns off...

Page 16: ...acity Error 304 Calibration error Calibration cannot proceed when environmental noises are too strong Please calibrate in a stable environment free of wind vibration etc Error 802 Unable to tare becau...

Page 17: ...peatability 0 1 g Linearity 1 d d 0 1 g 0 5 g Indication Limit 2060 0 g 72 660 oz Power Supply 5 V 500 mA Battery Lithium ion rechargeable 3 7 V 1100 mAh Battery Life 30 40 Hours Display 8 digit LED B...

Page 18: ...l rights reserved No part of this manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means with...