Settings Menu

Settings

Display

Sub-Menu Options

Default

Sleep Timer Setting

SLEEP

5, 10, 20, 30, 60, Off

5

Brightness Setting

bright

1, 2, 3, 4

2

Battery Saving Setting

bAttSavE

30, 90, 180, Off

90

Default Weighing Unit Setting

Unit 

Gram, Ounce

Gram

Key Sound Setting

bEEP

On, Off

On

Weighing Mode Setting

NOdE_1

On, Off

On

Dual Display Mode Setting

NOdE_2

On, Off

On

Timer Starts with Flow Mode Setting  

NOdE_3

On, Off

On

Auto-Tare Timer Starts with Flow Mode 

Setting

NOdE_4

On, Off

On

Auto-Tare Auto-Start Timer Mode Setting  

NOdE_5

On, Off

On

Auto-Tare Mode Setting  

NOdE_6

On, Off

On

Flow-Rate Indicator Setting

FLorAtE. d 

Default, Grad, Off

  Default

Average Flow-Rate Setting

Avg. FLo

On, Off

On

Weight Stable Indicator Setting

StAbLE. d 

On, Off

Off

Auto-Reset Setting

Auto_rES

Off, 10, 30

30

Pre-infusion Time Out Setting

PrE_inFu

10, 30, 60, 120

60

Auto-Start Sensitivity Setting

SEnSE

0.1, 0.2,

 

Off

Off

Weighing Resolution Setting

rESoL

Default, High

Default

Weighing Filter Setting

FiLtEr 

Fast, Normal, High

Fast

Zero Tracking Setting

trAcE

0.5 d, 1 d, 2 d, 3 d, Off

1 d

Zero Range Setting

0. rAnGE

2., 100.

100

Bluetooth Setup Setting

bt _SEt

On, Off

On

Reset to Default Setting

rESE t. d

No, Yes

No

16

Summary of Contents for AL010

Page 1: ...Acaia Lunar User Manual AL008 AL009 AL010 FW 1 0 009...

Page 2: ...ator Brewing with Flow Rate Indicator Tare Save Mode Introduction Mode 1 Weighing Mode Mode 2 Dual Display Mode Mode 3 Timer Starts with Flow Mode Mode 4 Auto Tare Timer Starts with Flow Mode Mode 5 A...

Page 3: ...njury or physical damage Thank you for choosing our scale The Acaia Lunar is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience Start by checking yo...

Page 4: ...e the scale on a stable and vibration free surface at a preferably horizontal location 4 Press to turn on the scale Double tap to turn off the scale Press to tare zero the weight Press and hold to swi...

Page 5: ...Power button until the battery percentage is displayed You can also check the battery level by connecting the scale to Acaia Apps Product Care Information Turn on the Acaia scale Turn on scale Make su...

Page 6: ...ed brightness indicating a high flow rate During an espresso brew the Flow Rate Indicator will display the highest peak flow rate of this brew with a single bright LED The Flow Rate Indicator can be a...

Page 7: ...on the display When brewing is completed and the cup is removed from the scale the display will flash to show the final beverage weight and the average flow rate of the brewing The Flow Rate Indicator...

Page 8: ...stable The weight is stored as a preset container weight Press and hold Tare button for 0 5 second The scale will display the weight to be deducted You may continue using your scale The net weight is...

Page 9: ...e funtion is supported in this mode There are two different weighing units in Dual Display Mode gram and ounce In grams the LED display shows 0 00 0 0 In ounces the LED display shows 0 00 0 000 The ti...

Page 10: ...the flow of espresso the timer starts The timer will stop when the flow stops Please note The flow detection mode is designed to detect the slow trickle of a shot of espresso The timer may not trigge...

Page 11: ...would like to measure the time of the shot starting from the first few drops of espresso When the weight reading is stable the scale will perform the auto tare operation After the scale detects the e...

Page 12: ...ht is placed on the scale Tare Weight Tare function starts when a stable weight is placed on the scale Stop Timer The timer will stop when flow is no longer detected Reset Mode Double tap Tare button...

Page 13: ...scale Reset Mode Double tap Tare button Switch Mode Press and hold Power button The LED display shows 0 0 with the weight in grams The LED display shows 0 000 with the weight in ounces Display In this...

Page 14: ...al beverage weight and the average flow rate of the brewing If the scale remains idle for 30 seconds it will reset the timer and perform the tare operation This feature is ideal for streamlining bar w...

Page 15: ...ttings The first setting is SLEEP 3 Please refer to the following table for key operations Configuration Enter Settings Action Operation Next Setting Tap Tare button Enter Setting Press and hold Tare...

Page 16: ...to Start Timer Mode Setting NOdE_5 On Off On Auto Tare Mode Setting NOdE_6 On Off On Flow Rate Indicator Setting FLorAtE d Default Grad Off Default Average Flow Rate Setting Avg FLo On Off On Weight S...

Page 17: ...of time in seconds before the scale enters battery saving mode 3 Tap the Tare button to toggle through the options Default Unit Setting Unit The Default Weighing Unit is set to grams if 9 is selected...

Page 18: ...e Weight Stable Indicator on the bottom left of the display lights up when the weight is stable 3 Off Weight Stable Indicator disabled Auto Reset Setting Auto_rES 1 After a cup is removed the timer an...

Page 19: ...vision is 0 1 g 3 d 0 3 g When Zero Tracking is set to be 3 d any initial weight between 0 3 g on the weighing pan will be zeroed out gradually 4 2 d is recommended in general for the Acaia Lunar Zero...

Page 20: ...on Tare Tap to tare weight Tare and Reset Timer While in Auto Start Modes double tap to zero weight and reset timer Save Subtract Press and hold for 2 seconds to save the container weight Press and ho...

Page 21: ...es The indicator also lights up during software update to indicate data transfer Button Pressed Indicator This indicator turns on when a button is pressed Auto Start Timer with Flow Indicator When the...

Page 22: ...he weight is over the maximum capacity Under load the weight is under the minimum capacity 304 Calibration error Calibration cannot proceed when environmental noises are too strong Please calibrate in...

Page 23: ...n Limit 2060 g 72 66 oz Power Supply 5 V 500 mA Battery Lithium ion rechargeable 3 7 V 1100 mAh Battery Life 30 40 hours Display 8 digit LED Material Aluminum Acrylic Surface Anodized aluminum coating...

Page 24: ...l rights reserved No part of this manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means with...

Reviews: