Action
Operation
Start Timer
The timer will start when the flow is detected
Tare Weight
Tare function starts when a stable weight is placed on the scale
Stop Timer
The timer will stop when flow is no longer detected
Reset Mode
Double tap Tare button
Switch Mode
Press and hold Power button
Mode 4 - Auto-Tare Timer Starts with Flow Mode -
Droplet and Square
• In grams, the LED display shows [ 0:00 0.0 ].
• In ounces, the LED display shows [ 0:00 0.000 ].
• The timer displays from [ 0:00 ] to [ 9:59 ] and then stops.
Display
Mode Description
This mode is designed for baristas who would like to
measure the time of the shot starting from the first few
drops of espresso. When the weight reading is stable,
the scale will perform the auto-tare operation. After
the scale detects the espresso flow, the timer starts
automatically. The timer will stop automatically when
the espresso flow stops.
11
The droplet and square icon
indicate that you are in Auto-Tare
Timer Starts with Flow Mode.
The timer starts when the flow of
espresso is detected.
Place a cup on the scale, and it will
perform auto-tare.
The timer will stop automatically
when the espresso flow stops or the
cup is removed.
1
3
2
4
• The auto-tare function operates when a stable weight is placed on the scale.
• The timer will start automatically when the flow of espresso is detected.