Operation 

Open the Protective Sensor Cap 

Twist the protective sensor cap, located at the top of the meter, 
counter-clockwise a quarter of a turn to expose the sensors.

 

Turn Power ON or OFF 

Press the 

[ON/OFF]

 button to turn power on or off. The meter will 

perform a short self-test when turned on. 

Taking measurements 

1. Hold the probe in the area to be tested.
2. Allow adequate time for readings to stabilize.
3. The Relative Humidity measurement appears in the right display along with the date and time.
4. Air Temperature appears in the top left display.
5. Wet Bulb is in the lower left display.
6. Pressing the 

[T1

T/DP

SEL

]

 button toggles the top left display between Air temperature, T1

temperature, Air-T1, and DP (Dew Point).

7. Pressing the 

[T2

WB

]

 button toggles the lower left display between WB (Wet Bulb), T1-T2, T2,

and T1-DP (Dew Point).

SETUP 

When the meter is off, press and hold the 

[ON/OFF

SET

button for more than 2 seconds to enter setup 

mode.   Prnt will appear on the display. 

1.

Selecting temperature units of measure (C/F)

Momentarily press the 

[T1

T/DP

SEL

]

 button until “unit” appears in the display.  

Press the 

[MEM]

 button to toggle between C or F.  

Press the 

[T2

WB

]

 button to confirm the setting and return to normal operation. 

2.

Setting the Date/Time (24 hour clock)

Press the 

[T1

T/DP

SEL

]

 button to select Year, Month, Day, Hour and Minute in sequence.  

Press the 

[MEM]

 button to change the settings. 

Press the 

[T2

WB

]

 button to confirm the date/time setting and return to normal operation. 

Data Hold 

Press the 

[REC

HOLD

]

 button momentarily to freeze the displayed reading. The '

HLD

' icon will appear 

on the upper right-hand side of the display. Press the 

[REC

HOLD

]

 button again to return to normal 

operation. 

Minimum (MN) Maximum (MX) Average (AVG) Function 

The MIN/MAX/Average mode allows the user to view only the lowest (

MN

), highest (

MX

) or average 

readings. Press the 

[M

in

/AV

RST

]

 button once and 

MN

 appears on the display. The display is now 

showing the lowest humidity and temperature readings in memory. Press the 

[M

in

/AV

RST

]

 button again 

and 

MX

 appears on the display. The display is now showing the maximum humidity and temperature 

readings in memory. Press the 

[M

in

/AV

RST

]

 button again to display the average (

AVG

) readings in 

memory. To exit the MIN/MAX/AVG mode, press the 

[M

in

/AV

RST

]

 button. To clear the current 

min/max/avg readings in memory, press and hold the

 [M

in

/AV

RST

button for more than two seconds. 