6
h. I Feel Control Mode
• Pressing the I Feel Button programs the unit to ambient temperature settings.
i. Compulsory Defrosting Function
• While the unit is on, set Heating Mode using remote controller.
• Adjust the temperature to 60.8ºF.
• Press “+, -, +, -, +, -,” buttons successively within 5 seconds. This will put the system into Compulsory Defrosting
status.
• The unit will exit Compulsory Defrosting status based on defrosting results. It will then resume normal heating
function.
j. Refrigerant Recovery Function – QUALIFIED TECHNICIAN ONLY
• Power on the unit.
• Continuously press the LIGHT Button 3 times within 3 seconds to enter refrigerant cycling mode.
• When the recycling function has started, Fo will be displayed on the remote.
• Close liquid valve and wait 5 minutes.
• After 5 minutes has passed, depress valve. If no refrigerant comes out, close the gas valve immediately and turn off
the unit in order to remove the connection pipe.
• Exit the Refrigeration Recycling Function.
• If the Refrigerant Recovery Function has been activated and not turned off, the unit will automatically exit Refrigerant
Recovery Mode after 25 minutes.
• If the unit is in Standby Mode before Refrigerant Recovery Function is activated, it will return to Standby Mode upon
completion of Refrigerant Cycling.
k. Ambient Temperature Display Control Mode
• Temperature setting range is 60.8ºF - 86.0ºF.
• The set temperature will be the default temperature displayed on the remote controller. If the user switches the
temperature to view ambient temperature, ambient temperature will remain displayed for 3 seconds. Afterward, it will
return to the set temperature.
• Indoor unit fan will operate at the user’s set fan speed.
• Indoor fan can operate at HIGH, MEDIUM, LOW, or AUTO fan speed.
l. Off-Peak Function
• The default minimum stop time is 180 seconds meaning the time interval between two start-ups of the compressor
cannot be less than 180 seconds.
m. SE Control Mode
• The unit operates at SE status.
n. X-Fan Mode
• When X-Fan function is engaged, the indoor fan will still operate at low speed for 2 minutes. After 2 minutes, the entire
unit will shut down.
o. 8ºC/46ºF Heating Function
• In heating mode, you can set the 8ºC/46ºF heating function using the remote controller. The system will operate at
8ºC/46ºF set temperature.
p. Turbo Fan Control Function
• Set turbo function in cooling or heating mode. Press fan speed button to cancel turbo function.
• Turbo feature is not available in AUTO, DRY, or FAN mode(s).