WARRANTY
43
INSTRUCTION MANUAL
HARDWARE
AED Electronics, Inc. warrants the original end user (“Customer”) that new Climatouch
™
branded
products will be free from defects in workmanship and materials, under normal use, for two (2)
years from the original purchase date.
SOFTWARE
AED Electronics, Inc. warrants to Customer that the Climatouch
™
thermostat software will perform
in substantial conformance to its program specifications for a period of two (2) years from the
date of the original purchase.
EXCLUSIONS
This warranty excludes (1) physical damage to the surface of the product, including cracks or
scratches on the touch-screen or outside casing; (2) damage caused by misuse, neglect, improper
installation, unauthorized attempts to open, repair, or modify the product, or any other cause
beyond the range of intended use; (3) damage caused by accident, fire, power changes, other
hazard, or Acts of God; or (4) use of the product with any device if such device causes the problem.
EXCLUSIVE REMEDIES
Should a covered defect occur during the warranty period and Customer notifies AED Electronics,
Inc., Customer’s sole and exclusive remedy will be, at AED Electronics, Inc.’s sole option and
expense, to repair or replace the product. Replacement products or parts may be new or recon-
ditioned or a comparable version of the defective item. AED Electronics, Inc. warrants any replaced
product or part for a period of ninety (90) days from shipment, or through the end of the original
warranty, whichever is longer.
OBTAINING WARRANTY SERVICE
Customer must contact and return product to a local AED Electronics, Inc. product dealer or
installer within the applicable warranty period to obtain warranty service. Dated proof of original
purchase will be required. AED Electronics, Inc. will not be responsible for Customer’s memory
data contained in, stored on, or integrated with any products returned to AED Electronics, Inc.
for repair, whether under warranty or not.
WARRANTY EXCLUSIVE
THE FORGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, CORRESPONDENCE WITH DESCRIPTION, AND NON-
INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED BY AED Electronics, Inc. AND
ITS SUPPLIERS..
DISCLAIMER
NEITHER AED Electronics, Inc. NOR ITS SUPPLIERS SHALL BE LIABLE FOR INCIDENTAL, CON-
SEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FINANCIAL LOSS
ARISING OUT OF OR IN CONNECTION WITH THE SALE OR USE OF THIS PRODUCT, WHETHER
BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE) OR ANY OTHER THEORY, EVEN IF AED
Electronics, Inc. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AED Electronics,
Inc.’S ENTIRE LIABILITY SHALL BE LIMITED TO REPLACEMENT OR REPAIR OF THE PRODUCT.
IMPORTANT NOTICE
42
Climatouch
™
CT0-7TC-32
>
>
WHEN USING THIS THERMOSTAT WITH A GAS FURNACE A COMMON WIRE (C)
MUST BE CONNECTED.
When working without a common wire:
>
>
A confirm in HEAT MODE the cooling does not switch on or B confirm in COOL
MODE the heat do es not switch on.
>
>
If test A or B fail or the thermostat shuts down in either HEAT or COOL MODE
then it is necessary to connect a common wire, (C), alternatively it may be possible
to solve this issue by simply connecting the 250 ohm 10 watt resistor between C
and W (in the case of a cooling problem - see B) or between C and Y1 (in the case
of a heating problem - see A) at the HVAC equipment.
>
>
When working without a common wire, A confirm that when there is a call for
heat, cooling does not also activate, and when there is a call for cool, heating
does not also activate.
>
>
If using the configuration of Heat Pump and Furnace with no Common Wire confirm
that when Heat Pump and Furnace are working together (both stages are operating
at the same time) that the display does not go blank, if so you must use a Common
Wire.
>
>
This thermostat is equipped to run with two separated power transformers if
required RC and RH. Terminals RC and RH are internally connected together however
you should wish to use two transformers simply cut with a blade the copper trace on
the printed circuit board located between the C and Y2 screw terminals.