background image

WARRANTY

43

INSTRUCTION MANUAL

HARDWARE

AED Electronics, Inc. warrants the original end user (“Customer”) that new Climatouch

branded

products will be free from defects in workmanship and materials, under normal use, for two (2)
years from the original purchase date.

SOFTWARE

AED Electronics, Inc. warrants to Customer that the Climatouch

thermostat software will perform

in substantial conformance to its program specifications for a period of two (2) years from the
date of the original purchase.

EXCLUSIONS

This warranty excludes (1) physical damage to the surface of the product, including cracks or
scratches on the touch-screen or outside casing; (2) damage caused by misuse, neglect, improper
installation, unauthorized attempts to open, repair, or modify the product, or any other cause
beyond the range of intended use; (3) damage caused by accident, fire, power changes, other
hazard, or Acts of God; or (4) use of the product with any device if such device causes the problem.

EXCLUSIVE REMEDIES

Should a covered defect occur during the warranty period and Customer notifies AED Electronics,
Inc., Customer’s sole and exclusive remedy will be, at AED Electronics, Inc.’s sole option and
expense, to repair or replace the product. Replacement products or parts may be new or recon-
ditioned or a comparable version of the defective item. AED Electronics, Inc. warrants any replaced
product or part for a period of ninety (90) days from shipment, or through the end of the original
warranty, whichever is longer.

OBTAINING WARRANTY SERVICE

Customer must contact and return product to a local AED Electronics, Inc. product dealer or
installer within the applicable warranty period to obtain warranty service. Dated proof of original
purchase will be required. AED Electronics, Inc. will not be responsible for Customer’s memory
data contained in, stored on, or integrated with any products returned to AED Electronics, Inc.
for repair, whether under warranty or not. 

WARRANTY EXCLUSIVE

THE FORGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS
FOR  A  PARTICULAR  PURPOSE,  CORRESPONDENCE  WITH  DESCRIPTION,  AND  NON-
INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED BY AED Electronics, Inc. AND
ITS SUPPLIERS..

DISCLAIMER

NEITHER AED Electronics, Inc. NOR ITS SUPPLIERS SHALL BE LIABLE FOR INCIDENTAL, CON-
SEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FINANCIAL LOSS
ARISING OUT OF OR IN CONNECTION WITH THE SALE OR USE OF THIS PRODUCT, WHETHER
BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE) OR ANY OTHER THEORY, EVEN IF AED
Electronics, Inc. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AED Electronics,
Inc.’S ENTIRE LIABILITY SHALL BE LIMITED TO REPLACEMENT OR REPAIR OF THE PRODUCT.

IMPORTANT NOTICE 

42

Climatouch

CT0-7TC-32

>

>

WHEN USING THIS THERMOSTAT WITH A GAS FURNACE A COMMON WIRE (C)
MUST BE CONNECTED. 

When working without a common wire: 

>

>

A confirm in HEAT MODE the cooling does not switch on or B confirm in COOL
MODE the heat do     es not switch on.

>

>

If test A or B fail or the thermostat shuts down in either HEAT or COOL MODE
then it is necessary to connect a common wire, (C), alternatively it may be possible
to solve this issue by simply connecting the 250 ohm 10 watt resistor between C
and W (in the case of a cooling problem - see B) or between C and Y1 (in the case
of a heating problem - see A) at the HVAC equipment. 

>

>

When working without a common wire, A confirm that when there is a call for
heat, cooling does not also activate, and when there is a call for cool, heating
does not also activate. 

>

>

If using the configuration of Heat Pump and Furnace with no Common Wire confirm
that when Heat Pump and Furnace are working together (both stages are operating
at the same time) that the display does not go blank, if so you must use a Common
Wire. 

>

>

This thermostat is equipped to run with two separated power transformers if
required RC and RH. Terminals RC and RH are internally connected together however
you should wish to use two transformers simply cut with a blade the copper trace on
the printed circuit board located between the C and Y2 screw terminals.

Summary of Contents for 90064

Page 1: ...2 YEAR WARRANTY www CLIMATOUCH com INSTRUCTION MANUAL Climatouch CT0 7TC 32 3 Heating and 2 Cooling with Dual Fuel Switch ...

Page 2: ... TE ER R A AN ND D R RE EC CE EI IV VE ER R K KI IT T Climatouch Part No 90064 Outdoor Wireless Temperature Transmitter and Receiver Kit Includes Transmitter Antenna Receiver Module 2 AA Batteries U S Patent 6 902 117 Accurately Displays Current Outdoor Temperature on the Climatouch Thermostat and Enables Dual Fuel Capability ...

Page 3: ...LE THERMOSTAT MODE 40 TROUBLESHOOTING 41 IMPORTANT NOTICE 42 WARRANTY 43 Climatouch CT0 7TC 32 Introducing the Climatouch CT0 7TC 32 touch screen thermostat with 3 stage heating 2 stage cooling control and fossil fuel switch available only when combined with Climatouch Outdoor Wireless Transmitter and Receiver Kit Climatouch Part No 90064 7 Day programmable with 4 events per day including fan Larg...

Page 4: ...eriod of time Cycle rate is often given in units of cycles per hour CPH DIFFERENTIAL Differential is defined as the difference between the cut in and cut out points as measured at the thermostat under specified operating conditions For example if the thermostat turns the heating equipment on at 70 degrees F and turns the heating equipment off at 74 degrees F then the differential is 4 degrees F PR...

Page 5: ...heating and cooling units should be OFF 2 Separate the backplate from the thermostat by grasping the unit firmly at the bottom lip and pulling gently until the two piece are apart 3 Align the backplate to the wall 4 Mark the three locations for drilling the 3 16 holes required for the plastic screw anchors 5 Remove the backplate and drill the three 3 16 holes in these locations 6 Insert the plasti...

Page 6: ...UE 24V RED Heat WHT Fan GRN AC YLW COMMON BLUE 24V RED Fan GRN AC YLW COMMON BLUE AC2 YLW 24V RED Fan GRN AC1 YLW COMMON BLUE WIRING DIAGRAMS 11 INSTRUCTION MANUAL AC AND TWO HEAT AC AND ONE HEAT WIRING DIAGRAMS 10 Climatouch CT0 7TC 32 TWO AC ONE AC ...

Page 7: ...4V RED Reverse Valves ORG Fan GRN HP YLW COMMON BLUE 24V RED 2nd Stage Heat 1st Stage Heat WHT Fan GRN AC YLW COMMON BLUE WIRING DIAGRAMS 13 INSTRUCTION MANUAL ONE HEAT PUMP AND ONE HEAT ONE HEAT PUMP WIRING DIAGRAMS 12 Climatouch CT0 7TC 32 AC AND TWO STAGE FURNACE ...

Page 8: ...ves ORG Fan GRN HP 1 YLW COMMON BLUE Heat 2 24V RED Reverse Valves ORG Heat 1 WHT Fan GRN HP YLW COMMON BLUE WIRING DIAGRAMS 15 INSTRUCTION MANUAL TWO TRANSFORMER ONE TRANSFORMER WIRING DIAGRAMS 14 Climatouch CT0 7TC 32 TWO HEAT PUMP ONE HEAT PUMP AND TWO HEAT ...

Page 9: ...l mode button Select the Fan Operation Mode by toggling the fan operation mode button Access MENU SCREEN to enter into all thermostat features and settings Displays Installer Message to review important information CONTROL SCREEN 17 INSTRUCTION MANUAL ToaccesstheCONTROLSCREEN simplytouchtheHOMESCREENScreen anywhere From the CONTROL SCREEN you can Current Room Temperature Current Outdoor Temperatur...

Page 10: ...CONTROL MODES 19 INSTRUCTION MANUAL Based on your HVAC equipment Climatouch can operate in the following tem perature control modes AUTO or HEAT or EMERGENCY HEAT or COOL or OFF AUTO Climatouch keeps the room tempe ...

Page 11: ...hen there is a demand for heating or cooling FAN ON The fan runs continuously FAN INTERMITTENT The fan runs 10 minutes per 1 2 hour providing a convenient way to improve air quality and save energy When the fan is running the animated fan icon will appear on the HOME SCREEN 20 Climatouch CT0 7TC 32 FAN OPERATION MODES ...

Page 12: ... of the HVAC system and should be performed only by a qualified installer 23 INSTRUCTION MANUAL MENU SCREEN 22 Climatouch CT0 7TC 32 To access the MENU SCREEN simply touch MENU from the CONTROL SCREEN From the MENU page you can Access DATE AND TIME SETTINGS to enter the accurate date and time Access PROGRAM SETTINGS to pre program temperature changes during each day of the week Access ENERGY WATCH...

Page 13: ...d FAN OPERATION MODE by fan operation mode button Enter the event START TIME with Hour Minute and AM PM buttons Choose desired TEMPERATURE SET POINT with and buttons Select the next event and repeat the steps described above Once finished select the next day of the week that you would like to program Climatouch will prompt you to copy the settings Repeat steps to program other days of the week 24 ...

Page 14: ... normal display at 6 00AM OFF screen background is determined by REVERSE function CONTRAST Toggle the screen contrast settings button 1 10 to select the screen contrast that suits best your thermostat surroundings Climatouch recommends the setting of 7 26 Climatouch CT0 7TC 32 ENERGY WATCH ENERGY WATCH feature provides a report on the energy con sumption and the dollar cost of operating your HVAC ...

Page 15: ...ort upon your return IMPORTANT HEAT or COOL must be selected from the CONTROL SCREEN before entering the Vacation Settings screen To begin select Vacation Mode ON Select the START Date Select the END Date Adjust the HEAT or COOL temperature setpoint the Vacation mode begins at 10 PM on the day of your departure and ends at Midnight on the day of your arrival When the Vacation mode is active the su...

Page 16: ...L DAYLIGHT TIME Choose Daylight Time ON or OFF dependent on your Time Zone FILTER Enter the air filter fan run time information here The Filter Monitor feature uses this information to inform you when to change your air filter by displaying CHANGE FILTER icon on the HOME SCREEN ENERGY WATCH Enter the HVAC system consumption parameters rounded off to kW as well as your electrical energy cost kW and...

Page 17: ...ure in Celsius 5 c to 25 c Temperature in Fahrenheit 13 F to 41 F 1 Available only in combination with WIRELESS OUTDOOR TEMPERATURE TRANSMITTER AND RECEIVER KIT 90064 ADVANCED SETTINGS SYSTEM CONFIGURATION 32 Climatouch CT0 7TC 32 IMPORTANT By inadvertently modifying system configuration settings you may seriously degrade HVAC system performance Choose system heating and cooling equipment remember...

Page 18: ...1 will function until Stage 2 is activated to help raise or cool temperature if the temperature set point is not reached This unique function avoids excess compressor wear in the case where the necessary temperature set point is not met through setting of the Staging Differential Set to 00 to disable ...

Page 19: ...7TC 32 ADVANCED SETTINGS HEAT PUMP HP ON when Furnace On Heat Pump and Furnace can operate together when 2nd stage furnace is required HP OFF when Furnace On turns off the Heat Pump when the furnace is On required on some gas or oil furnaces ...

Page 20: ... 6 F 3 0 C 2 5 5 F 2 5 C 2 0 4 F 2 0 C 1 5 3 F 1 5 C 1 0 2 F 1 0 C 0 5 1 F 5 C ADVANCED SETTINGS CALIBRATION 38 Climatouch CT0 7TC 32 Calibration of Temperature Your Climatouch Thermostat is rated for an accuracy of 1 F 1 C If you have determined due to drafts sunlight or other environmental factors that your thermostat requires calibration follow this easy guide Common cause of offset are lack of...

Page 21: ... of heating problem between C and Y1 I forgot my PIN and cannot unlock the thermostat Remove the cover plate press the reset button located in the bottom right corner as soon as the message touch to reset password appears touch the screen your PIN will be erased and the thermostat will unlock SIMPLE THERMOSTAT MODE 40 Climatouch CT0 7TC 32 Climatouch can also function as a virtual non programmable...

Page 22: ...RRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED BY AED Electronics Inc AND ITS SUPPLIERS DISCLAIMER NEITHER AED Electronics Inc NOR ITS SUPPLIERS SHALL BE LIABLE FOR INCIDENTAL CON SEQUENTIAL I...

Page 23: ...SIRED OPERATION TECHNICAL SUPPORT 1 866 90TOUCH 1 866 908 6824 PHYSICAL DIMENSIONS Case 5 75 x 4 75 x 1 25 145mm x 120mm x 30mm Screen 4 1875 106mm ELECTRICAL RATING 24 volt AC DC Class 2 maximum 4 amps Temperature Accuracy 1 F 0 5 C Humidity Accuracy 5 RH PATENTS 7 156 318 7 145 110 7 050 026 7 028 912 6 902 117 6 786 421 Other Patents Pending AED Electronics Inc 5758 Royalmount Ave Montreal QC H...

Reviews: