background image

SECURITY

: The security settings allow you

to protect your Climatouch

thermostat

from unauthorized use.

Turn Security 

ON

or 

OFF

. You will be prompted to enter the

PIN. The Default PIN 1111.

To

CHANGE PIN

, enter your new PIN and then, when prompt-

ed, re-enter your new PIN.

Choose a security mode by toggling SECURITY MODE button:

FULL LOCK

does not allow any changes unless the user enters

the PIN. 

PARTIAL LOCK

allows you to change only the temperature

setpoint without entering a PIN. 

Enter the INSTALLER MESSAGE: (up to 42
characters) to appear at programmable

intervals. Type the message using the keyboard, and push OK
button to confirm. You will be prompted to enter the number of
months after which you would like the message to appear.

ADVANCED SETTINGS - FEATURES SETTINGS

31

INSTRUCTION MANUAL

::

DAYLIGHT TIME

: Choose Daylight Time 

ON

or 

OFF

dependent on your Time Zone.

FILTER:

Enter the air filter "fan run time"

information here. The Filter Monitor feature
uses this information to inform you when
to  change  your  air  filter  by  displaying
CHANGE FILTER icon on the HOME SCREEN.

ENERGY WATCH:

Enter the HVAC system

consumption parameters (rounded off to
kW) as well as  your electrical energy cost
(¢/kW) and the ENERGY WATCH feature
will display a real time totals of electrical
energy consumption and cost. To review
touch the ENERGY WATCH button on the MENU SCREEN. 

*

EXAMPLE: Fan 1kW, Heat Pump 1kW/ton, Furnace 5-30 kW, 7-9¢/kW

ENERGY WATCH

feature will run consecutively for 255 days. If you do not enter your

information what will appear on the display is the total time the Compressor and
the Furnace have been operating.

Select temperature display in either 

CELSIUS 

or

FAHRENHEIT

degrees by toggling the °C / °F button to either °C or °F.

ADVANCED SETTINGS - FEATURES SETTINGS

30

Climatouch

CT0-7TC-32

Summary of Contents for 90064

Page 1: ...2 YEAR WARRANTY www CLIMATOUCH com INSTRUCTION MANUAL Climatouch CT0 7TC 32 3 Heating and 2 Cooling with Dual Fuel Switch ...

Page 2: ... TE ER R A AN ND D R RE EC CE EI IV VE ER R K KI IT T Climatouch Part No 90064 Outdoor Wireless Temperature Transmitter and Receiver Kit Includes Transmitter Antenna Receiver Module 2 AA Batteries U S Patent 6 902 117 Accurately Displays Current Outdoor Temperature on the Climatouch Thermostat and Enables Dual Fuel Capability ...

Page 3: ...LE THERMOSTAT MODE 40 TROUBLESHOOTING 41 IMPORTANT NOTICE 42 WARRANTY 43 Climatouch CT0 7TC 32 Introducing the Climatouch CT0 7TC 32 touch screen thermostat with 3 stage heating 2 stage cooling control and fossil fuel switch available only when combined with Climatouch Outdoor Wireless Transmitter and Receiver Kit Climatouch Part No 90064 7 Day programmable with 4 events per day including fan Larg...

Page 4: ...eriod of time Cycle rate is often given in units of cycles per hour CPH DIFFERENTIAL Differential is defined as the difference between the cut in and cut out points as measured at the thermostat under specified operating conditions For example if the thermostat turns the heating equipment on at 70 degrees F and turns the heating equipment off at 74 degrees F then the differential is 4 degrees F PR...

Page 5: ...heating and cooling units should be OFF 2 Separate the backplate from the thermostat by grasping the unit firmly at the bottom lip and pulling gently until the two piece are apart 3 Align the backplate to the wall 4 Mark the three locations for drilling the 3 16 holes required for the plastic screw anchors 5 Remove the backplate and drill the three 3 16 holes in these locations 6 Insert the plasti...

Page 6: ...UE 24V RED Heat WHT Fan GRN AC YLW COMMON BLUE 24V RED Fan GRN AC YLW COMMON BLUE AC2 YLW 24V RED Fan GRN AC1 YLW COMMON BLUE WIRING DIAGRAMS 11 INSTRUCTION MANUAL AC AND TWO HEAT AC AND ONE HEAT WIRING DIAGRAMS 10 Climatouch CT0 7TC 32 TWO AC ONE AC ...

Page 7: ...4V RED Reverse Valves ORG Fan GRN HP YLW COMMON BLUE 24V RED 2nd Stage Heat 1st Stage Heat WHT Fan GRN AC YLW COMMON BLUE WIRING DIAGRAMS 13 INSTRUCTION MANUAL ONE HEAT PUMP AND ONE HEAT ONE HEAT PUMP WIRING DIAGRAMS 12 Climatouch CT0 7TC 32 AC AND TWO STAGE FURNACE ...

Page 8: ...ves ORG Fan GRN HP 1 YLW COMMON BLUE Heat 2 24V RED Reverse Valves ORG Heat 1 WHT Fan GRN HP YLW COMMON BLUE WIRING DIAGRAMS 15 INSTRUCTION MANUAL TWO TRANSFORMER ONE TRANSFORMER WIRING DIAGRAMS 14 Climatouch CT0 7TC 32 TWO HEAT PUMP ONE HEAT PUMP AND TWO HEAT ...

Page 9: ...l mode button Select the Fan Operation Mode by toggling the fan operation mode button Access MENU SCREEN to enter into all thermostat features and settings Displays Installer Message to review important information CONTROL SCREEN 17 INSTRUCTION MANUAL ToaccesstheCONTROLSCREEN simplytouchtheHOMESCREENScreen anywhere From the CONTROL SCREEN you can Current Room Temperature Current Outdoor Temperatur...

Page 10: ...CONTROL MODES 19 INSTRUCTION MANUAL Based on your HVAC equipment Climatouch can operate in the following tem perature control modes AUTO or HEAT or EMERGENCY HEAT or COOL or OFF AUTO Climatouch keeps the room tempe ...

Page 11: ...hen there is a demand for heating or cooling FAN ON The fan runs continuously FAN INTERMITTENT The fan runs 10 minutes per 1 2 hour providing a convenient way to improve air quality and save energy When the fan is running the animated fan icon will appear on the HOME SCREEN 20 Climatouch CT0 7TC 32 FAN OPERATION MODES ...

Page 12: ... of the HVAC system and should be performed only by a qualified installer 23 INSTRUCTION MANUAL MENU SCREEN 22 Climatouch CT0 7TC 32 To access the MENU SCREEN simply touch MENU from the CONTROL SCREEN From the MENU page you can Access DATE AND TIME SETTINGS to enter the accurate date and time Access PROGRAM SETTINGS to pre program temperature changes during each day of the week Access ENERGY WATCH...

Page 13: ...d FAN OPERATION MODE by fan operation mode button Enter the event START TIME with Hour Minute and AM PM buttons Choose desired TEMPERATURE SET POINT with and buttons Select the next event and repeat the steps described above Once finished select the next day of the week that you would like to program Climatouch will prompt you to copy the settings Repeat steps to program other days of the week 24 ...

Page 14: ... normal display at 6 00AM OFF screen background is determined by REVERSE function CONTRAST Toggle the screen contrast settings button 1 10 to select the screen contrast that suits best your thermostat surroundings Climatouch recommends the setting of 7 26 Climatouch CT0 7TC 32 ENERGY WATCH ENERGY WATCH feature provides a report on the energy con sumption and the dollar cost of operating your HVAC ...

Page 15: ...ort upon your return IMPORTANT HEAT or COOL must be selected from the CONTROL SCREEN before entering the Vacation Settings screen To begin select Vacation Mode ON Select the START Date Select the END Date Adjust the HEAT or COOL temperature setpoint the Vacation mode begins at 10 PM on the day of your departure and ends at Midnight on the day of your arrival When the Vacation mode is active the su...

Page 16: ...L DAYLIGHT TIME Choose Daylight Time ON or OFF dependent on your Time Zone FILTER Enter the air filter fan run time information here The Filter Monitor feature uses this information to inform you when to change your air filter by displaying CHANGE FILTER icon on the HOME SCREEN ENERGY WATCH Enter the HVAC system consumption parameters rounded off to kW as well as your electrical energy cost kW and...

Page 17: ...ure in Celsius 5 c to 25 c Temperature in Fahrenheit 13 F to 41 F 1 Available only in combination with WIRELESS OUTDOOR TEMPERATURE TRANSMITTER AND RECEIVER KIT 90064 ADVANCED SETTINGS SYSTEM CONFIGURATION 32 Climatouch CT0 7TC 32 IMPORTANT By inadvertently modifying system configuration settings you may seriously degrade HVAC system performance Choose system heating and cooling equipment remember...

Page 18: ...1 will function until Stage 2 is activated to help raise or cool temperature if the temperature set point is not reached This unique function avoids excess compressor wear in the case where the necessary temperature set point is not met through setting of the Staging Differential Set to 00 to disable ...

Page 19: ...7TC 32 ADVANCED SETTINGS HEAT PUMP HP ON when Furnace On Heat Pump and Furnace can operate together when 2nd stage furnace is required HP OFF when Furnace On turns off the Heat Pump when the furnace is On required on some gas or oil furnaces ...

Page 20: ... 6 F 3 0 C 2 5 5 F 2 5 C 2 0 4 F 2 0 C 1 5 3 F 1 5 C 1 0 2 F 1 0 C 0 5 1 F 5 C ADVANCED SETTINGS CALIBRATION 38 Climatouch CT0 7TC 32 Calibration of Temperature Your Climatouch Thermostat is rated for an accuracy of 1 F 1 C If you have determined due to drafts sunlight or other environmental factors that your thermostat requires calibration follow this easy guide Common cause of offset are lack of...

Page 21: ... of heating problem between C and Y1 I forgot my PIN and cannot unlock the thermostat Remove the cover plate press the reset button located in the bottom right corner as soon as the message touch to reset password appears touch the screen your PIN will be erased and the thermostat will unlock SIMPLE THERMOSTAT MODE 40 Climatouch CT0 7TC 32 Climatouch can also function as a virtual non programmable...

Page 22: ...RRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED BY AED Electronics Inc AND ITS SUPPLIERS DISCLAIMER NEITHER AED Electronics Inc NOR ITS SUPPLIERS SHALL BE LIABLE FOR INCIDENTAL CON SEQUENTIAL I...

Page 23: ...SIRED OPERATION TECHNICAL SUPPORT 1 866 90TOUCH 1 866 908 6824 PHYSICAL DIMENSIONS Case 5 75 x 4 75 x 1 25 145mm x 120mm x 30mm Screen 4 1875 106mm ELECTRICAL RATING 24 volt AC DC Class 2 maximum 4 amps Temperature Accuracy 1 F 0 5 C Humidity Accuracy 5 RH PATENTS 7 156 318 7 145 110 7 050 026 7 028 912 6 902 117 6 786 421 Other Patents Pending AED Electronics Inc 5758 Royalmount Ave Montreal QC H...

Reviews: