15
13. Alarms
The wireless alarm system has three different types of alarm. Depending on the system state (deactivated, internally activated, activated) or triggered alarm zone
(technical alarm, panic alarm, burglar alarm, fire alarm), one of the following alarms can be triggered:
•
Local / internal alarm
•
External alarm
•
Silent alarm
13.1. Local / internal alarm
In the event of a local alarm, the following are
activated:
•
The alarm system siren
•
The info module siren
•
The
external
siren
only with a local
alarm
(the acoustic alarm is active for 3
minutes and the visual alarm is active
until the system is deactivated)
•
The relay of the accessory module (if
programmed)
A local alarm is caused by:
•
A tamper alarm when the system is
deactivated
•
An alarm in the technical zones
•
An alarm in each zone of the system
(except zones with entry/exit delay) when
the system is activated (if programmed)
•
An unsuccessful activation due to
exceeding the exit delay time
•
Exceeding the first entry delay time
13.2. External alarm
In the case of an external alarm, the following are
activated:
•
The alarm system siren
•
The info module siren
•
The external siren (the acoustic alarm is
active for 3 minutes and the visual alarm
is active until the system is deactivated)
•
Alarm transmission by telephone
•
The relay of the accessory module (if
programmed)
An external alarm is caused by:
•
A tamper alarm when the system is
activated
•
An alarm in the 24-hour zones and fire
zones when the system is activated and
deactivated
•
An alarm in each zone of the system
(except zones with entry/exit delay) when
the system is activated (if programmed)
•
Exceeding the second entry delay time
13.3. Silent alarm
In the case of a silent alarm, the following are
activated:
•
No acoustic or visual alarm
•
Alarm transmission by telephone only
•
The relay of the accessory module (if
programmed)
A silent alarm is caused by:
•
A panic alarm (if programmed)
•
An alarm in each zone of the system
(except zones with entry/exit delay) when
the system is activated (if programmed)
Keep calm in the event of an alarm, regardless of the type. Not every alarm is an intrusion. Most alarms have other causes. Check the situation carefully and take
considered action accordingly. Deactivate the system, check the reason for the alarm and then reset the alarm. If you receive an alarm by telephone, follow the
steps in section 15.