Before starting installation, identify a suitable installation location for the Wireless
Outdoor Sounder using the wireless test box. Ensure that the sounder is installed out
of hand’s reach (minimum 3 m installation height). In addition, the sounder should be
visible and audible from afar.
Incorrect or unclean installation work may lead to erroneous interpretation of signals.
The consequences of which may include false alarms. The costs incurred by
potential dispatches of rescue services, such as the fire service or police, must be
borne by the operator of the system.
To ensure trouble-free operation, the sounder must NOT be installed:
close to large metal structures, such as metal doors or frames, water tanks, vehicles
and refrigerators
close to the main power supply, or close to water or gas pipelines
inside a metal housing
next to electronic devices, especially computers, photocopiers and radios.
Caution
Switch the Secvest alarm panel to installer mode before starting any installation or
maintenance work. Installer mode prevents the sounder and the flashing light from
being activated when the sounder’s cover is opened. This prevents you being
startled
because the sounder remains
silent
.