Funk-Anzeigemodul_FA01_31.03.09 31.03.2009 16:17 Uhr Seite 15
Probedruck
C
M
Y
CM
MY
CY CMY
K
We reserve the right to make technical changes. No liability for mistakes and printing errors. ABUS © 2009
Hold the bottom of the radio controlled display module on the desired installation position and mark the three
drill holes; drill with a 6 mm drill; insert dowel and screw on the bottom part.
Caution:
Length of cable on power supply 1.50 metres. A nearby 230 VAC receptacle is required.
After completing the teaching process, put the top part of the radio controlled display module on the installed
bottom section and secure to the bottom section with the enclosed screws.
IX.
Technical data
Voltage supply:
12V power supply
Frequency: 868.6625
MHz / FM
Zones:
16, individually programmable
Weight:
516 g
Dimensions W x H x D: 135 x 220 x 45
mm
Environmental Class:
I
Temperature range:
0
°
C to + 50
°
C
VIII. Installation
Hint:
Before installing the detector and the radio controlled display module, make sure that there is a reliable
radio connection between the intended installation positions.
To ensure permanently secure radio reception, at least three LEDs should be illuminated per alarm (see Point VI. f).
15
ABUS - The good feeling of security
www.abus-sc.com