Abtus ABT 4610 Laser Offset Gauge Instruction Manual Download Page 3

 

 

 

 

 

 

 

4610-1 Issue 04 

 

2.0 

Item List

 

1.  1off Height and Stagger Gauge 
2.  1off PDA (Personal digital assistant) 
3.  2off Hilti PDE Laser 
4.  2off Laser Carriage 
5.  1off Platform Square 
6.  1off Instruction Manual 
7.  1off Hilti Documentation 
8.  1off PADDED BAG 

 
 
 
 
 
 
 
 
 
 
 

 

3.0  Specification 

Features 

Fully insulated 

Expected Battery Life

—1year (Inclinometer) 

Back Light on laser display for Night/Tunnel work 

 

4.0 Getting Started 

4.1 

Overview 

The ABT 4610 is the latest edition to the Abtus data-logging range. The purpose 
of the product is to allow the user to take height and distance offset readings from 
the running rails to a desired object or position. 
Height and Offset values are displayed on a PDA allowing the operator on 
track/site exactly what has been measured at that given position. These values 
are calculations of measurements taken from a laser and inclinometer fitted to the 
gauge.  The technique used to calculate the height and offset values enables 
objects to be measured even if they are below rail level. 
The tool is constructed from lightweight GRP and Nylon with a weight of just 
8.0kg, ensuring that the gauge is insulated from the track circuit. Set up time is 
less than 30 seconds. The vertical and horizontal sections are unfolded then 

 

Summary of Contents for ABT 4610 Laser Offset Gauge

Page 1: ...4610 1 Issue 04 ABT4610 Laser Offset Gauge Instruction Manual ...

Page 2: ...erview 2 4 2 Assembly 4 4 3 Measuring Super Elevation 5 5 0 Operating the Gauge and Software 5 1 Turn on the Control Unit by pressing and holding the on button please refer to manufacturers instructions as control units can vary 5 6 0 Maintenance 7 6 1 Before Each Use 7 6 2 Every 3 Months 7 6 3 Annual 7 ...

Page 3: ...ow the user to take height and distance offset readings from the running rails to a desired object or position Height and Offset values are displayed on a PDA allowing the operator on track site exactly what has been measured at that given position These values are calculations of measurements taken from a laser and inclinometer fitted to the gauge The technique used to calculate the height and of...

Page 4: ...he software to calculate the super elevation of the track which can be used for platform gauge working Once the data is input into the PDA it can be saved to file and then downloaded to a PC and kept as a permanent record of the survey For increased speed or for measuring bridge arches a second laser can be used to locate the position of non fixed points Datum plate height offset measurement Platf...

Page 5: ...er Carriage by extending the front sprung plate as shown in figure 2 4 Carry the tool to the point on the rail opposite the measurement target Place the Laser Carriage into an appropriate Pivot Socket and lock in the socket using the Locking knob attached as shown in figure 2 Switch the Laser Rangefinder on to ensure that laser falls onto target 5 Switch on Inclinometer and Laser Rangefinder Remov...

Page 6: ...the Gauge and Software 1 Turn on the Control Unit by pressing and holding the on button please refer to manufacturers instructions as control units can vary 2 Select 1 of three options New File starts new file Open File opens existing file No Save starts new file without option to save Enter a file name and then select appropriate button for type of measurement required Dat Datum Plt Platform O H ...

Page 7: ...ing from the inclinometer into PDA and press calculate Indicated in image below 4 To enter a reading into PDA tap once on each white box and use the keypad that appears 5 If an error occurs as image below then one or more laser readings taken were not accurate and all three must be taken again Note Using all three Pivot Sockets gives best accuracy When necessary to use two only then Pivot Sockets ...

Page 8: ...n and can move freely 2 Ensure that the vertical beam locks firmly into place 3 Ensure all batteries are fully functioning 6 2 Every 3 Months 1 Visually check for damage 6 3 Annual To ensure that the accuracy of your ABT4610 remains within specified limits it should be returned to your local distributor for annual re calibration ...

Reviews: