background image

 

G100-XXL  is  a  main  member  of  digital-chargers  from 

.  It  represents  today’s  new  technology  for  12.8V(4s)  ~ 

34.8V(12s) 

Li-Ion/Polymer/FePo4 

battery 

pack 

charging. 

G100-XXL 

programmed  3  auto  stages  (  Ip-Im-Um)  charging  process

It  is  designed  for   

3~25Ah  Li-Ion/Polymer/LiFePo4  battery  pack.  Stage  “Ip”    is  a  pre-charge 

function for deep discharged battery pack, this is helpful for battery’s cycle life. 

When  the  battery  recovered  by  pre-charge  small  current,  stage  “Im”  will  give 

bulk  current  charging.  Then,  “Um”  stage  is  followed,  the  output  voltage  is 

limited  on  14.4V(for  4S  LiFePo4)  or  16.8V(for  4S  Li-ion/polymer),  until  the 

charge  current  declined  to  0.4A.  At  this  stage,  the  battery  is  charged 

completely and the charger will cut off output automatic. 

Further, G100-XXL can display the charging process, indicate the battery 

capacity from 25% to 100% timely. This is helpful for user. 

For  more  safety,  G100-XXL  will  inter  protection  mode  when  the  battery 

polarity reversed our the output connectors shorted.   

Specification for G100-XXL 

Input Voltage 

100-240VAC

50-60Hz 

Input Current 

1.6A 

Back current drain 1

 

<1mA 

G100-12LF 

G100-24L 

G100-36L 

G100-36LF 

Charge voltage limit 

14.4V+-1% 

29.4V+-1% 

42V+-1% 

43.2V+-1% 

Bulk charge current 

4.5A+-5% 

2.8A+-5% 

1.8A+-5% 

Operate Temperature 

-20

~50

 

Cooling 

Natural convection. Do not cover the charger.

 

Charge principle 

Auto 3 stages: Ip-Im-Um   

Cut-off when charge finished. 

Battery type 

From 12.8V(4s) to 38.4V(12s),    Li-ion/Polymer/LiFePo4

 

Battery capacity 

3-25Ah 

Size 

170X70X51mm 

Enclosure 

IP54 (

Dust protected, Water splashing resistance)

 

Weight 

400g 

 

 
 

 

Display Panel   

 

 

 

 

 

 

 

 

 

 

 

 

 

How to use: 

1.

 

Connect the AC cord to the socket, The “power” lamp will light on solid. 

 

2.

 

Connect positive charger clip (red) to positive battery terminal, the black clip 

to  negative.  (You  can  use  other  dc  plugs  to  connect  battery),  the 
“25%~100%” lamps will  light on flowing. If the battery polarity reversed or 

output shorted, “Warning” lamp will flashing, please check the setup.

 

3.

 

Depend  on  the  charged  capacity,  25%~100%  lamps  will  lights  up  solid 
sequence,  until  the  battery  is  fully  charged.  Then  you  can  power  off  the 

charger and disconnect the battery or you can charge a new battery if you 

need.

 

The table shows the duration of 80% state charged for an empty battery.

 

Battery cap. 

G100-12LF 

G100-24L 

G100-36L 

3.2Ah 

Not recommend 

1.5 hours 

2 hours 

7.0Ah 

2 hours 

3 hours 

4 hours 

12Ah 

3 hours 

5 hours 

7 hours 

25Ah 

6 hours 

10 hours 

13 hours 

 

Charging process indicator: 

Indicate  battery  capacity  from  25%  to  100%  when 

charging.   

All lamps flashing means battery polarity reversed or 

output shorted. 

All lamps are “off” means no battery. 

Power    on 
(When 

AC 

input OK) 

Shenzhen ABT