background image

32

SECTION 6 DIMENSIONS

15-inch

38.10 cm

14-inch

35.56 cm

7-inch

17.78 cm

26.5-inch

67.31 cm

14-inch

35.56 cm

7-inch

17.78 cm

7-inch

17.78 cm

19-inch

48.26 cm

14-inch

35.56 cm

ATLAS

 

MAGNUM

 

TITAN

 

®

®

®

27 7/8-inch

70.80 cm

16 5/16-inch

41.43 cm

12-inch (30.48 cm)

1/4 x Places 

Weight: 26 - 32 lbs.

Weight: 26 - 32 lbs.

Weight: 53 lbs.

12-inch (30.48 cm)

Summary of Contents for ATLAS 30

Page 1: ...NUM ATLAS TITAN MAGNUM OZONE GENERATOR OZONE GENERATOR Operator s Manual CONTACT Address 10712 181 ST NW Edmonton Alberta Canada T5S1K8 Phone Email Ph 1 780 486 3761 Toll Free 1 800 488 8565 E office...

Page 2: ...trol Panel Overview 3B System Start Up 3C System Shut Down 3D Standard Operating Procedures Section 4 Maintenance and Service 4A Preventative Maintenance 4B Troubleshooting Section 5 Ozone Overview an...

Page 3: ...edure 5D iv Respiration Protection 5D v Education and Training 5E System Operations and Maintenance 5E i Safety Precautions and Equipment 5E ii Maintenance Requirements 5F Monitoring Equipment and loc...

Page 4: ...ator with safe access to electrical power Connect to a GFCI type receptacle Follow all applicable electrical codes Do not bury chord WARNING To reduce the risk of electrical shock please ensure to rep...

Page 5: ...g Pools etc Industrial Processes Chemical Production and Laboratories Elec tronic Production Mining Aquatic Life Support Systems for Marine Mammals Fish Hatcher ies Large Aquarium Food Processing Food...

Page 6: ...0 60Hz 3 5A Max Power Cons 220W ATLAS 30C TITAN 30C 30 9 16 ATLAS 30 UHC TITAN 30 UHC 23 9 22 ATLAS 60 TITAN 60 60 25 40 6 12 120V 3 50 60Hz 8 0A 220V 3 50 60Hz 6 0A Max Power Cons 550 W ATLAS 80 TITA...

Page 7: ...nd Accessories Oxygen Generator Concentrator The oxygen generator uses a PSA pressure swing absorption molecular sieve bed to remove dirt moisture nitrogen and other trace gases producing oxygen at gr...

Page 8: ...mal perfor mance ALD 2000 Flood Prevention Device We recommend installing an ALD 2000 with every ozone system treating water to prevent water freom backing up into the ozone generator and damaging it...

Page 9: ...m of 90 of the ozone gas into the water flow continuously Ozone De gas Chamber and Off Gas Device Ozone en riched wa ter from the ozone injector flows into the de gas chamber where the counter current...

Page 10: ...t can be installed indoors or outdoors IF protected from weather elements Ambient working temperature from 10C to 30C Reversible Universal Control Panel We had to strive for efficiency in every detail...

Page 11: ...r Cell from water exposure which may cause internal cell damage A small tank with or an automatic water drain system is recommended Stackable Without a Rack Every Absolute Ozone ozone generator comes...

Page 12: ...of a buffer tank with an appropriate hi low pressure switch It is VERY IM PORTANT to protect the Generator from any possible contamination from the Oxygen Concentrator or water injection device by ins...

Page 13: ...n for the gen erator to be On and closed to stop the Ozone production That switch has to be connected to dry contacts only not connected to the ground on any kind or to any voltage source AC or DC Rem...

Page 14: ...troller protects the generator from connecting to an incorrect power source Incorrect wiring or voltage applied to the remote control terminals Incorrect operating pressure Ozone cell contamination by...

Page 15: ...the screen power selected by the remote control or slider Actual power Watt going to an ozone cell The cell voltage V Current Amp going to the ozone cell Gas pressure inside the ozone cell Temperatur...

Page 16: ...e sure the Ozone Generator enclosure is securely attached to an appropriate frame or wall Ozone Generators Stack 2 Make sure all connections to the generator power and gas are made according to local...

Page 17: ...ity and less than 60 C dew point Check sieve conditions and replace it as often as recom mended by the manufacturer Install an oxygen filter and oxygen dryer between the oxygen con centrator and the O...

Page 18: ...acturer 2 Remove and replace or clean filter cartridges and other devices if installed and required 3 Perform general cleaning of cabinet exterior after disconnecting the equipment from the electrical...

Page 19: ...conductive liquids please switch the ozone generator off locate and eliminate the source of the contamination while having power off run oxygen through the ozone cell for several days to dry the liqu...

Page 20: ...to specified pressure and that will rectify this problem and warning message Symptom Warning Message OZONE CELL TEMPERATURE TOO HIGH Make sure that the ambient temperature in the installation room is...

Page 21: ...ine 2 25 Hydroxyl Radical 2 05 Ozone 1 52 Hydrogen Peroxide 1 30 Hypochlorite 1 10 Chlorine 1 00 Chlorine Dioxide 0 93 Bromine 0 57 5A ii Micro Flocculation and Oxidation Ozone oxidizes the following...

Page 22: ...non carcinogenic Hazardous polymerization can occur in some rear materials Spontaneously decomposes to oxygen gas SECTION 5 OVERVIEW AND SAFETY PROCEDURES 5B ii General Safety Informatio Ozone Uses A...

Page 23: ...ly Dangerous to Life or Health IDLH SECTION 5 OVERVIEW AND SAFETY PROCEDURES 5C ii Health Hazards Effect in Humans Gaseous ozone acts as a primary irritant affecting mainly the eyes up per respiratory...

Page 24: ...y the electrical cord To reduce the risk of electrical shock replace the damaged cord immediately SECTION 5 OVERVIEW AND SAFETY PROCEDURES 5C iv Fire Hazards Ozone is nonflammable Decomposition of ozo...

Page 25: ...zone into the outside atmo sphere Federal state and local regulations must be followed 5D iii Emergency Procedure Due to the short life of ozone evacuation and ventilation are all that is generally re...

Page 26: ...lities with regard to not only specific work procedures but also the need to report all haz ards accidents or incidents and injuries Management and employees shall review all routine work and emergenc...

Page 27: ...system shall be tested and serviced according to the manufacturer s instructions The planned maintenance of all safety equipment is es sential to worker safety SECTION 5 OVERVIEW AND SAFETY PROCEDURE...

Page 28: ...ii Inhalation 1 Assess worker s breathing 2 All unconscious workers must be placed in the drainage position on their sides so that fluids can drain from the airways once breathing has been restored 3...

Page 29: ...physician before working in an area in which they may be exposed to ozone Significant alterations in cardiopulmonary functions have been documented when such workers have been ex posed to low concent...

Page 30: ...components Absolute Ozone will assist with warranty claims for such components pur chased through Absolute Ozone limited to the extent of the manufacturer s standard warranty ANY REPAIR OR REPLACEMENT...

Page 31: ...RVICE BY ABSOLUTE OZONE TO OBTAIN WARRANTY SERVICE Please provide the following information 1 Project contact name mailing address and telephone 2 Installer Mechanical Contractor 3 Serial and date of...

Page 32: ...7 78 cm 26 5 inch 67 31 cm 14 inch 35 56 cm 7 inch 17 78 cm 7 inch 17 78 cm 19 inch 48 26 cm 14 inch 35 56 cm ATLAS MAGNUM TITAN 27 7 8 inch 70 80 cm 16 5 16 inch 41 43 cm 12 inch 30 48 cm 1 4 x Place...

Page 33: ...as Absolute Ozone generators do not require any service repairs or maintenance rst 20 years of use when installed and used cor rectly CALL US TODAY AND LET S DISCUSS YOUR UPCOMING OR CURRENT PROJECT...

Reviews: