background image

PL Lite Series

User Manual

- 23 -

5

Maintenance

5.1 Tools for Maintenance

Preparation of maintenance tools:

List

Type

Function

Picture

Front

maintenance tool

Installing and fixing

module

Phillips

screwdriver

Installing and

disassembling module

& power supply &

screw on receiving card

multimeter

Measuring power lines

and distribution boxes

Small Phillips

screwdriver

Installing and removing

mask

Spirit level

Measuring structure

Laser spirit level

Measuring installation

position

Band tape

Measuring distance of

installation hole

Summary of Contents for PL Lite Series

Page 1: ...Shenzhen Absen Optoelectronic Co Ltd PL Lite Series User Manual ...

Page 2: ...ging bar Illustration 14 3 1 2 Hanging bar installation 15 3 2 Stacking Installation 18 4 Product Cabling 18 4 1Preparation Before Cabling 18 4 2 Power Supply and Signal Cable Wiring 19 4 2 1 Product Component Illustration 19 4 2 2 Standard Cable Wiring 22 5 Maintenance 23 5 1 Tools for Maintenance 23 5 2 Maintenance Instructions 24 5 2 1 Module Maintenance 24 5 2 2 Power Box Maintenance 25 5 2 3 ...

Page 3: ...eware of Electric Shock To prevent electric shock the device must be properly grounded during installation Do not ignore using the grounding plug or else there is a risk of electric shock During a lightning storm please disconnect the device s power supply or provide other suitable lightning protection If the equipment is not in use for a long time please unplug the power cord When performing any ...

Page 4: ...y the product do not add or remove parts Do not use the product in case ambient temperature is over 55 Beware of Injury Warning Wear a helmet to avoid injury Ensure any structures used to support fix and connect the equipment can withstand at least 10 times the weight of all the equipment When stacking products please hold products firmly to prevent tipping or falling Ensure all components and ste...

Page 5: ...ule are sensitive and can be damaged by ESD electrostatic discharge To prevent damage to LED lamps do not touch when the device is running or switched off WARNING The manufacturer shall not bear any responsibility for any incorrect inappropriate irresponsible or unsafe system installation ...

Page 6: ...lay including 2 5 2 9 3 9 and 4 8mm among which P3 9 P4 8 have outdoor version There are also curve version and cube version PL2 5 Lite PL2 9 Lite PL3 9 Lite PL3 9W Lite only The PL lite series uses die casting aluminum structure with modern cabinet featuring excellent flatness high quality cabinet and module finish and high structural strength Cube Products PL2 5 lite PL2 9 lite PL3 9 lite PL3 9W...

Page 7: ... which significantly improves customers satisfaction The brightness of PL3 9W lite and PL4 8W lite can reach 4500nit Moreover ultra high contrast and distinct color layers ensure excellent visual outdoor effects The curved version supports any increment of curve from 7 5 convex to 10 concave giving user unlimited flexibility in design and operation Advanced locking system with safety mechanism ena...

Page 8: ...erial Die cast Aluminum Cabinet Weight Cabinet 7 6 7 6 8 11 7 Grayscale 14 Refresh Rate Hz 3840 Drive Mode 1 20 1 28 1 16 1 16 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 1000 Viewing Angle H V 140 140 140 140 140 140 140 140 Electrical Parameters AC Input Voltage V 100 240 Power Consumption Max Avg W m2 580 190 540 180 540 180 540 180 E...

Page 9: ... Cabinet Weight Cabinet 7 8 12 6 7 8 12 6 Grayscale 14 Refresh Rate Hz 3840 Drive Mode 1 8 1 8 1 7 1 7 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 4500 Viewing Angle H V 140 120 140 120 140 120 140 120 Electrical Parameters AC Input Voltage V 100 240 Power Consumption Max Avg W m2 570 190 570 190 570 190 570 190 Environmental Parameters ...

Page 10: ...8 Grayscale 14 Refresh Rate Hz 3840 Drive Mode 1 20 1 28 1 16 1 8 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 1000 1000 1000 4500 Viewing Angle H V 140 140 140 140 140 140 140 120 Electrical Parameters AC Input Voltage V 100 240 Power Consumption Max Avg W m2 580 190 540 180 540 180 570 190 Environmental Parameters Storage Temperature C ...

Page 11: ...PL Lite Series User Manual 11 1 3 Cabinet dimension figure Unit mm 500 88 mm 500 1000 500 88 500 500 88 ...

Page 12: ... Series User Manual 2 Product Components 2 1 Cabinet Introduction Locking system Locking system Locking system module Power box Locking system Locking system Module Power box Curved lock Curved lock Locking system ...

Page 13: ...forms of installation including rigging and stacking installation Use the locking system to lock the cabinets during installation The curved lock can support radian connection from 7 5 to 10 Standard locking Lock up and down Locking system Locking system Locking Module Power box Curved lock ...

Page 14: ...g 90 Corner 3 1 Hanging Installation 3 1 1 Hanging bar Illustration Used for rigging installation including single double hanging bar and 90 degree hanging bar Remove the movable lock on the splicing surface Two connection blocks are required to secure the connection of the two corner cabinets ...

Page 15: ...Installation steps 1 Fix the Hanging Bar on the Truss 2 Align the safe lock on the cabinet with the mounting hole on the hanging beam 3 Press the locking plate on the hanging beam 4 Insert the safe lock on the cabinet up 5 Tighten the safe lock from left to right 6 Tighten the second cabinet as described above Note For detailed installation steps see the product installation video STEP Graphic 1 F...

Page 16: ...afe lock on the cabinet with the mounting hole on the hanging beam 3 Press the locking plate on the hanging beam 4 Insert the safe lock on the cabinet up 5 Tighten the safe lock from left to right 6 Align the left and right cabinet mounting holes ...

Page 17: ...PL Lite Series User Manual 17 7 Lock the left and right cabinet 8 Install other cabinets as described above 9 Install the module Single hanging bar Double hanging bar ...

Page 18: ...s equipped with a curved lock which support radian connection from 7 5 to 10 2 For the installation method of the cabinet please refer to the installation above 4 Product Cabling 4 1Preparation Before Cabling Please check carefully if the connection of power and signal circuit is correct before ...

Page 19: ...2 1 Product Component Illustration Distribution box The distribution box is a low voltage distribution box composed of switchgear measuring instruments protective devices and auxiliary devices which are assembled in a closed or semi closed metal cabinet or screen based on the electrical wiring requirements During normal operation the circuit can be switched on or off manually or automatically The ...

Page 20: ...sents L L L N line 1 represents PE line X represents the main cable size if the single phase voltage is 110V then the international copper core cable model must be twice the size Power supply Model MEGMEET MCP200WS 4 5A MEGMEET MSP260 4 5 Electrical Characteristics of Input Input voltage range 90Vac to 264Vac 90Vac to 264Vac Normal voltage range 100Vac to 240Vac 100Vac to 240Vac Frequency range 47...

Page 21: ...k the effect Play high definition content after starting up such as video text images etc It is suggested to make sure the resolution of the content is in consistent with that of the screen otherwise the content will be compressed thus affecting the overall performance 4 For software operation please refer to the software instruction manual Under different cabinet sizes and different input voltage...

Page 22: ... 22 PL Lite Series User Manual 4 2 2 Standard Cable Wiring 100V 120V or 220V 240V Signal Cable Distribution Box ...

Page 23: ...ing and fixing module Phillips screwdriver Installing and disassembling module power supply screw on receiving card multimeter Measuring power lines and distribution boxes Small Phillips screwdriver Installing and removing mask Spirit level Measuring structure Laser spirit level Measuring installation position Band tape Measuring distance of installation hole ...

Page 24: ...abinet which will not be repeated here Module front maintenance Step1 Attach the vacuum maintenance tool to the module and press the maintenance tool switch for 5 seconds Pull it vertically and pull the module off the panel Step2 Remove the failure module Step3 Replace with a good module Module rear maintenance Step1 Hold the module handle with your right hand and push it forward Step2 Remove the ...

Page 25: ... power box up and remove it Step3 Remove the fixed screw of power supply Step4 Replace with new power box Other cabinets Unscrew the loose screw of the power box and remove it for maintenance screw position is shown in the circle Attention It is necessary to cut off power supply of cabinets during the maintenance of the power box to avoid electric shock ...

Page 26: ...s 500 500 cabinets receiving card and HUB board can be customized to support the front maintenance Maintenance for receiving card Rear 1 Remove the screws of the receiving card please notice the Red frame mark 2 Unplug the receiving card and replace it 3 Install a new receiving card on the HUB board please note that the receiving card direction should correspond to the arrow direction on the HUB b...

Page 27: ...at the receiving card direction should correspond to the arrow direction on the HUB board please note the yellow border mark in the figure below Step 4 install the HUB board back note the direction of the HUB board and the corresponding screw hole Step 5 install the screw Step 6 install the power box and module 5 2 4 Flight Case Place the LED panels horizontally to prevent SMD damage Flight cases ...

Page 28: ...sponding module 6 Replace the module 7 Replace the receiving card 8 Send rcfg file 2 The whole screen is black 1 Check whether the screen power is on 2 Check whether the DVI cable or HDMI cable is loose 3 Check whether the main data cable is well inserted 4 Check whether the sending card is powered on and whether the running indicator is flashing 5 Replace the sending card 6 Connecting the compute...

Page 29: ...een connection on software 2 Check whether the data port is wrong 6 No control system detected 1 Check the USB cable 2 Check whether the computer USB port is malfunctioning 3 Update the USB driver 4 Replace the USB cable 5 Replace the sending card 7 No multi function card detected 1 Check whether the distribution box is in the automatic state 2 Check whether the multi function card is powered 3 Re...

Page 30: ... 30 PL Lite Series User Manual Shenzhen Absen Optoelectronic Co Ltd 18 20F Building 3A Cloud Park Bantian Longgang District Shenzhen 518129 P R China T 86 755 89747399 E absen absen com W www absen com ...