- 16 -

Power Cable Wiring

Total power for 8 cabinets with size 1152x288mm each is: 8x1.152x0.288x450w=1.2kw, arranged in 2x4 

with 2 cabinet columns, and 4 cabinets for each column connected to power supply in series. In this case 

use a 3X1.5m

m

2

 power cable to connect from the distribution box or socket to the bottom of the cabinet.

N Series

 User Manual

Network Cable Wiring

The network cable is connected from up to down in "S" shape. Please calculate the resolution as per 

288x72 pixels for each cabinet, and connect signal cables in accordance with the Signal Sending Card’s 

load range. Please note that the load pixel range for each network interface is not more than 650,000 

pixels.

Power Cable

Signal Cable

Leading 

LED

 Applications

DVI or HDMI plug

USB plug

Laptop

Signal Sending Box

Summary of Contents for N3

Page 1: ...Leading LED Applications User Manual N Series Easy Maintenance Fast Installation Slim Light Weight Front Rear Servicing High Grayscale Intelligent Monitor N3 N4 N4W N5 ...

Page 2: ...s Details 08 Cabinet Introduction Product Installation 13 14 Front Installation Instructions Wall mounting 15 16 16 17 17 18 Product Wiring 11 Front Installation Rear Installation Power Cable Wiring Power Supply Wiring Network Cable Wiring 15 12 13 Floor Installation Wall mounting Solution 12 Use Sub frame for Fast Installation Maintenance Preparation Tools Module Front Rear Maintenance 18 Check f...

Page 3: ... or installing the product The AC power used in this product must comply with local building and electrical codes and should be equipped with overload and ground fault protection The main power switch should be installed at a location near the product and should be clearly visible and easily reached This way in case of any failure the power can be promptly disconnected Before using this product ch...

Page 4: ...on the screen Do not modify the product do not add or remove parts Do not use the product in case ambient temperature is over 40 Beware of Injury Warning Wear a helmet to avoid injury Ensure any structures used to support fix and connect the equipment can withstand at least 10 times the weight of all the equipment When stacking products please hold products firmly to prevent tipping or falling Ens...

Page 5: ...y flat and smooth display plane precision cabinet and module assembly and very strong structure Standard Cabinet Dimension is 1152X288X54mm The product is primarily used at hotel ballrooms TV stations commercial chain stores branded snack stores transpor tation hubs supermarkets banks churches airports railway stations theaters company lobbies high end clubhouses museums large conference rooms and...

Page 6: ... 05 N Series User Manual Leading LED Applications 288mm 1152mm Cabinet Dimension Module Dimension 54mm 288mm 288mm L E D Product Dimensions ...

Page 7: ...ixel Matrix per Cabinet Drive Mode Module Size L W mm Frame Frequency Hz Cabinet Dimension L W H mm Cabinet Material Color Temperature K Brightness cd m2 Horizontal Viewing Angle Vertical Viewing Angle Contrast Rate AC Input Voltage V AC Input Frequency Hz Maximum AC Input Power W m2 Average AC Input Power W m2 Storage Temperature Working Temperature Storage Humidity RH Working Humidity RH IP Rati...

Page 8: ...ntenance channel requirement Magnetic modules enable fast and convenient module installation and disassembly without screws Cabinets can be installed both horizontally and vertically The module can be rotated along with cabinets by 90 degrees for assembly rotating the module and cabinet together does not affect the viewing angle ensuring the screen can be installed vertically to meet customers dif...

Page 9: ... Introduction Product Structure Electronic Components Details Cabinet structure Full aluminum cabinet is extremely thin and light Cabinet can be installed either horizon tally or vertically Mounting holes Positioning Column Power output Test button Indicator Power input Signal Input Output Horizontal Installation Vertical Installation ...

Page 10: ...er cable 10m length Modular structure Magnetic modules Relative to the cabinet structure modules can be rotated by 90 degrees for installation so that the cabinet can be installed vertically or horizontally When installed vertically the module needs to be rotated by 90 degrees so as not to affect left and right viewing angle 287 7mm 16 1mm 30 6mm 287 7mm 8 7 N L E N L E L N L N ...

Page 11: ... Installation use connecting plates and mounting bolts 4 in 1 Carton Packing 100mm 74mm 4mm 100mm 70mm Connecting Plates M8x60 Bolts Wooden Case Packing 1218 0mm 324 0mm N Series User Manual Leading LED Applications ...

Page 12: ...ounting holes to fix it to the steel structure After it is fixed properly connect power cord and signal lines and then restore the removed modules Use M8x60 bolts and connecting plates to fix onto the 40X40 square hollow bars Front Installation Rear Installation Product Installation Remove modules from both sides module Connecting Plates M8X60 Bolt M6X60 bolt fixed on steel structure Steel constru...

Page 13: ...to the support stand When installing first fix 4 2 to 4 cabinets onto the sub frame and then mount the sub frame onto the steel structure or wall to achieve fast installation Note Front or rear installation can also be used for sub frame installation Floor Installation Use Sub frame for fast installation Front installation hole Rear installation hole ...

Page 14: ...nstructions Wall mounting Install cabinets onto the sub frame or fixed structure and then directly mount the sub frame onto the wall to achieve wall mounting installation Step 1 Install cabinets onto the sub frame and splice 2 to 4 cabinets Number of cabinets is based on actual requirements at installation site Wall Wall mounting device ...

Page 15: ...b frame Step 3 According to the installation positions marked on the wall install M10 expansion screws Sub frame Module Installation hole Mark Step 5 After wiring is completed insert modules back at the four empty corners Repeat the same proce dures to install the next spliced cabinet Step 4 Install the cabinet Mount cabinets onto the wall corresponding to the M10 expansion screw positions and the...

Page 16: ...turer to specifically match Cabinet s input voltage is 100 240V AC and 3X1 5mm2 power cable is used to connect from distribution box to cabinet When input voltage is 220V each power supply can be used to supply power for maximum 16 cabinets When the input voltage is 110V each power supply can be used to supply power for maximum 8 cabinets Cabinet terminal connection diagram Take 2x4 cabinets for e...

Page 17: ...or socket to the bottom of the cabinet N Series User Manual Network Cable Wiring The network cable is connected from up to down in S shape Please calculate the resolution as per 288x72 pixels for each cabinet and connect signal cables in accordance with the Signal Sending Card s load range Please note that the load pixel range for each network interface is not more than 650 000 pixels Power Cable ...

Page 18: ... 17 Front Maintenance Tools Screwdriver Multimeter Tools front maintenance tools multimeter screwdriver etc Maintenance Preparation Tools N Series User Manual Leading LED Applications ...

Page 19: ...t wiring please use a multimeter to check if there is any short circuit at the AC input power supply L N PE and DC output terminal VCC GND If there is a short circuit please carefully investigate the wirings Make sure all wirings are normal and only then connect power to operate the unit Check for Power Supply Short Circuit Leading LED Applications ...

Page 20: ... Russelsheim Frankfurt Germany T 86 755 89747399 F 86 755 89747599 W www absen com V2 0 Nov 2015 All rights reserved by Shenzhen Absen Optoelectronic Co Ltd Shenzhen Absen Optoelectronic Co Ltd reserves the rights to modify contents without any further notice E absen absen com E stella hsia absen com E europe absen com T 49 0 6142 920 87 56 F 49 0 6142 920 87 57 W www absen com W www absen com T 1...

Reviews: