iCon C138/ iCon E138 Product Specifications 

Parameters

 

iCon C138 

iCon E138 

Physical 

Parameters

 

Pixels 

SMD1010 

Pixel Pitch (mm) 

1.58 

1.9 

Cabinet Pixels 

384×216 

320×180 

Pixel Density (Pixels / m

2

396424 

275295 

Module size (L × W)/(mm) 

305×343 

Cabinet size (L × W × H)/(mm) 

610×343×61 

610×343×61 

Cabinet Material 

Die-cast Aluminum 

Cabinet Weight (

/Cabinet) 

8.5 

8.5 

Electronic 

Parameters

 

Color Processing Depth (Bit) 

14 

Grayscale 

16384 

Refresh Rate (Hz) 

1920 

1920 

Drive Mode 

  1/24 

1/20 

Picture Frame Frequency (Hz) 

50/60 

Signal Transmission Distance (m) 

UTP cable:

100 m; Single-mode fiber:

10 km 

Optical 

Parameters

 

Brightness (nit) 

350 

Horizontal Viewing Angle (°) 

140 

Vertical Viewing Angle (°) 

140 

Electrical 

Parameters

 

AC Input Voltage (V) 

200~240 

100~240 

AC Input Frequency (Hz) 

50/60 

Maximum AC Input Power (W/m

2

360 

Average AC Input Power (W/m

2

120 

Environmental 

Parameters

 

Storage Temperature (

˚

C) 

—40~+60 

Working Temperature (

˚

C) 

—10~+40 

Storage Temperature (RH) 

10%~90% Non-condensing 

Working Humidity (RH) 

10%~90% Non-condensing 

Ingress Protection 

IP40/IP21 

Product Life (hrs) 

100000 

Leasing 
Product 

Installation

 

Cabinet Installation Method 

haring, stacking 

Maximum number of hoisted cabinets 

20 

20 

Summary of Contents for iCon C110

Page 1: ...iCon series User Manual Shenzhen Absen Optoelectronic Co Ltd ...

Page 2: ...Table of content Safety Information 03 Product Introduction 06 About iCon series 06 Product Specifications 07 Product Installation 16 Service and Maintenance 29 ...

Page 3: ...this manual carefully before installing powering up operating and maintenance of this product Follow safety instructions in this manual and on the product If you have any questions please seek help from Absen WARNING Please read the Safety Measures listed in this section carefully before installing switching on operating and maintenance of this product WARNING Safety Risk Might cause equipment dam...

Page 4: ...t a location near the product and should be clearly visible and easily reached This way in case of any failure the power can be promptly disconnected Before using this product check all electrical distribution equipment cables and all connected devices and make sure all meet current requirements Use appropriate power cords Please select the appropriate power cord according to the required power an...

Page 5: ...reen from within a 1 meter distance Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes Product Disposal Any component that has a recycling bin label can be recycled For more information on collecting reusing and recycling please contact the local or regional waste management unit Please contact us directly for detailed environmental perfor...

Page 6: ...e impact of the speech and promote the efficiency of the meeting The iCon series has the following products iCon C110 iCon C138 iCon C165 and iCon C220 In the future according to market demand other specifications will be introduced iCon E110 iCon E138 iCon E165 iCon E192 The iCon C110 iCon E110 iCon C138 and iCon E138 products are mainly used in the use of 30 person conference rooms The iCon C165...

Page 7: ......

Page 8: ......

Page 9: ...rame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 200 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 360 Average AC Input Power W m2 120 Environmental Parameters Storage Temperature C 40 60 Working Temperatu...

Page 10: ...e Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 200 240 100 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 360 Average AC Input Power W m2 120 Environmental Parameters Storage Temperature C 40 60 Working Temp...

Page 11: ...Picture Frame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 100 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 360 Average AC Input Power W m2 120 Environmental Parameters Storage Temperature C 40 60 Working ...

Page 12: ...e Frame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 350 Horizontal Viewing Angle 140 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 100 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 360 Average AC Input Power W m2 120 Environmental Parameters Storage Temperature C 40 60 Working Temper...

Page 13: ...2 Cabinet dimension figure 3 Module dimension figure ...

Page 14: ...Product Components 2 1 Cabinet Introduction 2 2 HDMI cable for vertical connections in between the cabinets 0 5m ...

Page 15: ...n the cabinets 0 95m 2 4 Power Cable 1 for vertical connections in between the cabinets 0 26 m long Power Cable 2 for vertical connections in between the cabinets 0 5 m long 2 5 Main Power Cable 10 m long 2 5mm 2 6 Main HDMI cable 5m long ...

Page 16: ...e position is the distance from the end face of the beam is 100mm the distance between the upper and lower wall joints is 900mm The distance between the lower frame and the wall joint is 305mm as shown in the figure below Step2 According to the position of the wall joint the hole is φ12mm deep and 55mm the expansion bolt M8x80 is used the wall joint piece is fixed and the flange nut M8 is fixed No...

Page 17: ... a total of 3 use the 3mm hex wrench to screw in the front side does not install the slot connector because the front may need to put the T nut to fix the hanging plate Note There is a tapping on one end of the beam and the tapping end cannot be placed in the middle Placement in the middle will result in the vertical beam not being fixed Cylindrical head hexagon bolts M8x30 fixed T bolt M6x16 and ...

Page 18: ...the hanging plate as shown below Note First screw all T nuts and screws into the middle and side hanging plate waist holes Step 6 Fix the first side hanging plate to the beam and align the side of the hanging plate with the cross section of the beam Note Side hang board alignment T nut Large flat head screw M6x10 Article 1 hanging board ...

Page 19: ...Step 7 Install the side hanging plate and the middle hanging plate from left to right Step 8 Put in the box and lock it ...

Page 20: ...ll the border and corner Install from the bottom up pay attention to the large frame screw M6x10 fixed frame to the box Step 10 Fixed distribution box ship type switch etc The position is the bottom of the cabinet ...

Page 21: ... iCon C165 E165 installation iCon E192 installation ...

Page 22: ... iCon C220 installation ...

Page 23: ...bumpers to the truss or the steel structure Connect the bumpers together using the metal connectors and make sure they are level Cabinet installation Assemble the cabinets from top down layer by layer align the coffin locks with the corresponding holes on the bumpers ...

Page 24: ......

Page 25: ...During installation make sure all the coffin locks are tightened in the direction of arrow as shown in the illustration ...

Page 26: ... source to the screen please check power and data cables connections carefully and make sure they are wired correctly Use a multimeter to test the L N and PE lines in AC power input port and make sure the tree lines are not short circuited Power cable connection description RJ45 USB HDMI IN HDMI OUT ...

Page 27: ...creen power cable can carry up to 32 cabinets ie iCon C110 iCon E110 iCon C138 iCon E138 screen comes standard with 1 3 2 5mm screen power cord iCon C165 iCon E165 iCon E192 iCon C220 screen comes standard with 2 3 2 5mm joint power cables ...

Page 28: ...DMI Cabling Notes The signal line adopts HDMI cable and the S type is connected up and down Please calculate the resolution according to each box pixel Each HDMI cable can control up to 1920 1080 pixels ...

Page 29: ...service tool clockwise all the way Step 2 Place the front service tool onto the module tightly and rotate the two rotation handles counterclockwise all the way Step 3 Hold the two handles on the tool and firmly pull the module out of its frame Step 4 Take modules off and place them in a safe area and then turn the two rotation handles clockwise all the way ...

Page 30: ... a multi meter to test the AC input L N PE and DC output VCC GND to determine whether there is a short circuit If a short circuit has been found please examine the circuit carefully Power up the cabinets only after making sure all the circuits are working properly ...

Page 31: ...en Absen Optoelectronic Co Ltd reserves the rights to modify contents without any further notice Shenzhen Absen Optoelectronic Co Ltd 18 20F Building 3A Cloud Park Bantian Longgang District Shenzhen 518129 P R China T 86 755 89747399 E absen absen com W www absen com ...

Reviews: