background image

 

 

A27 Plus

 Series User Manual                                                                                                                                        - 10 -

 

2.2.2 Hanging bar: single and double hanging bars. 

 

 

 

2.2.3 Data Jumper for vertical connections in between cabinets (Standard Version),   
0.5m long. 

 

2.2.4 Data Jumper for horizontal connections in between cabinets (Standard Version), 
0.8m long. 

 

2.2.5 Power Jumper for vertical connections in between cabinets: 0.3m long (Type 1).   

          Power Jumper for vertical connections in between cabinets: 0.5m long (Type 2). 

 

 

2.2.6 Power Jumper for horizontal connections in between cabinets: 0.9m long. 

 

 

Single Hanging Bar 

Double Hanging Bar 

Single Hanging Bar 

Summary of Contents for A27 Plus Series

Page 1: ...A27 Plus Series User Manual CCC CE FCC ETL Front service High contrast ratio High refresh rate Easy installation FHD 4K ...

Page 2: ... 在此处键入 A27 Plus Series User Manual ...

Page 3: ...onents 8 2 1 Cabinet Introduction 9 2 2 Product Component Drawing 9 3 Product Installation 12 3 1 Front Installation 13 3 2 Installation of Frame against Wall 13 3 3 Rear Installation 16 3 4 Rigging 16 4 Product Cabling 17 4 1 Power Supply Wiring 18 4 2 Signal Cable Wiring 18 4 3 The Test of Setting up an Electric Circuit 20 5 Maintenance 20 5 1 Preparation Tools 20 5 2 Maintenance Instructions 20...

Page 4: ...her suitable lightning protection If the equipment is not in use for a long time please unplug the power cord When performing any installation or maintenance work e g removing the fuses etc make sure to turn off the master switch Disconnect AC power when the product is not in use or before disassembling or installing the product The AC power used in this product must comply with local building and...

Page 5: ...ling repairing or moving the product ensure the working area is free of obstacles and ensure the working platform is securely and stably fixed In the absence of proper eye protection please do not look directly at the lit screen from within a 1 meter distance Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes WARNING Beware of suspended lo...

Page 6: ... Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequen cy energy and if not installed and used in accordance with the instruction manual may c ause harmful interference to radio communications Operation of this equipment in a resi dential ar...

Page 7: ...nce rooms as well as numerous other applications 1 1 Product Main Features A27 Plus series products have two optional version Standard Version and Smart Version The smart version has a HDMI interface and the video source can be directly input into the cabinet without sending card A27 Plus series cabinet is formed integrally by die casting It is made of aluminum alloy and has the characteristics of...

Page 8: ...s design eliminating noise reducing power consumption and saving energy Signals and power connections between the cabinets are connected quickly using crystal plugs and sockets reliable power plugs and sockets External test buttons and indicator lights are used to test cabinet and show running status at a glance High gray scale high refresh high gray in low light high contrast large viewing angle ...

Page 9: ...lor Temperature K 6500 Viewing Angle H V 160 140 160 140 140 110 160 140 160 140 Driving Type 1 15 1 27 1 40 1 48 1 45 AC Operating Voltage V 100 240 Power Consumption Max Avg W m 570 190 610 203 450 150 610 203 630 210 Application Parameter Storage Temperature Storage Temperature Storage Temperature Storage Temperature Storage Temperature Storage Temperature Storage Temperature Storage Temperatur...

Page 10: ...A27 Plus Series User Manual 8 1 3 Cabinet dimension figure mm 1 4 Module dimension figure mm 2 Product Components ...

Page 11: ...ect the cabinets while adjusting the gaps between the cabinets to ensure the flatness 2 2 Product Component Drawing 2 2 1 Mounting frame used for wall mounting including single and double frames Handle Upper and lower side locking screw Left and right locking screw 1X1 Single frame 1X2 Double frame ...

Page 12: ...4 Data Jumper for horizontal connections in between cabinets Standard Version 0 8m long 2 2 5 Power Jumper for vertical connections in between cabinets 0 3m long Type 1 Power Jumper for vertical connections in between cabinets 0 5m long Type 2 2 2 6 Power Jumper for horizontal connections in between cabinets 0 9m long Single Hanging Bar Double Hanging Bar Single Hanging Bar ...

Page 13: ...ll power in 10m long 2 2 8 Standard packaging Carton packing module and cabinet are packaged separately Package dimensions 805 120 435 mm Weight 8 kg 2 2 9 Connector plates and bolts are used for installations with steel structure Connector Plates M8 60 Screw Bolt ...

Page 14: ...uct Installation The product is suitable for various forms of installation including front installation rear installation and rigging Use the side locking screws to lock the cabinets during the installation Side locking screw Screw lockin ...

Page 15: ...ed onto the wall with mounting frames or onto the steel structure via the front mounting screw hole of the cabinet 3 2 Installation of frame against wall Step 1 Use M6 Tapping Screws or M6 Anchors to install the mounting frame onto a flat wall M8 installation hole M8 Bolt Hole ...

Page 16: ...nging pins onto the M8 holes of the cabinet with 4 hanging pins per cabinet Step 3 Install the cabinet without modules onto the frame install from bottom layer to top layer and fasten the cabinets with locking screws Locking screw Hanging pin Hanging pin ...

Page 17: ...module Please follow the instructions for this step as below From the front view module XX 1 is installed on the leftmost side of the cabinet and module XX 4 is installed on the rightmost side of the cabinet Note XX represents for cabinet number which should be exactly the same between cabinets and modules Module XX 1 Module XX 4 ...

Page 18: ...3 4 Rigging The product also supports rigging installation and the measured maximum load is 10 cabinets First the hanging bar is fixed on the truss or steel structure by the airplane belt or steel wire rope through the eye bolt and please make sure the adjacent hanging bars are connected by connecting blocks and kept on the same level l Connector Plates 40 40 mm Square Tube M8 60 Screw Bolt Connec...

Page 19: ...L N and PE lines in AC power input port and make sure the three lines are not short circuited Power cord connection instructions Please calculate and select the appropriate model of distribution box or socket according to the maximum power consumption Please consult your electrician or distribution cabinet manufacturer for specific selection scheme The input voltage of the cabinet is 100 240V AC T...

Page 20: ...onnect the distribution box or socket to the bottom of cabinet with 3 x 1 5mm2 16awg power cables 4 2 Signal Cable Wiring 4 2 1 Signal cable connection of standard product version The signal cable of standard version uses RJ45 CAT5 network cable and the network cable interface of the cabinet can be used for input and output For the S type of up down connection please calculate the resolution accor...

Page 21: ...ignated input and output ports The cabinets are cascaded in the form of S using data jumper cables Calculate total pixel load based on the resolution of the screen Each HDMI cable can handle up to 1920x1080 pixels The signal cable of smart version adopts HDMI cable and the upper and lower connection style is S shaped Please calculate the resolution according to pixels of each cabinet Each HDMI cab...

Page 22: ...arefully After ensuring the cable is normal switch on the power to electrify the cabinets to work Note Please refer to the software user manual for software operation 5 Maintenance 5 1 Preparation Tools Preparation tools include module front service tool Phillips screwdriver multimeter etc 5 2 Maintenance Instructions 5 2 1 Module Maintenance Put the front service tool onto the surface of the modu...

Page 23: ...nd put them in place Then use a Phillips screwdriver to remove the fixing screws of the HUB board The HUB board can be removed from the cabinet Note The power supply behind the HUB board should be pasted with heat dissipation glue When all screws are removed the HUB board should be pulled out of the cabinet by hand Button Fixing screw ...

Page 24: ...and the receiving card can be removed from the HUB board 5 2 4 Maintenance in front of Power Supply When maintaining the power supply the HUB board must be removed the black insulating film must be torn off and then the power supply fixing screws must be removed with a Phillips screwdriver The power supply can be removed from the back of the HUB board Receiving card Power supply fixing screws Insu...

Page 25: ... 23 A27 Plus Series User Manual Note After the power supply is replaced the front face of the HUB board needs to be subsidized with insulating plates Power supply ...

Reviews: