Absco Industries
Assembly Instruction Manual
GABLE SHED
N3/C1 FRAME KIT
FOR PREMIER MODELS
Model: CYCGK
02/03/21
1.5
7
INSTALL EXTRA FASTENERS
Absco sheds sheets have punched holes typically spaced at 592mm from centre to centre.
To achieve a cyclonic wind rating additional screws will need to be installed to reduce these distances.
The fastener intended at these positions is FAST001, a 10mm self tapping screw.
Pre-drill and reinforce with extra screws at
148mm
centres in the following locations
B
- Roof panel to wall
C
- Roof panel to ridge beam - inside
G
- Wall sheet to wall channel - inside
Pre-drill and reinforce with extra screws at
296mm
centres in the following locations
A
- All sheet-to-sheet connections
D
- Wall corners
E
- Roof lips to roof
F
- Sheet to channel
30302GK shown for illustrative purposes.
G
G