Specification #8810502
Original 5/14/98
ABS<Comtrak
1700-1702
Installation & Start-up Procedure
1
Revision, 1/5/99
General Operation:
The ABSComtrak
1700 (model 1700) system consists of a Personal Tracking Unit (PTU) and battery
charge system. During normal operation the PTU is to be connected to the battery charger for a minimum of
seven hours each day. It may than be run for a minimum of seventeen hours before a recharge is required.
During this period the client is free to move within the range, from the shoulder pack, that the wireless cuff
allows (+/- 20 ft. outdoors and +/- 30 ft. indoors). When moving from one location to the other (i.e. from
home to work) the client (with PTU) must remain /- 20 ft. of the shoulder pack to avoid a proximity
violation. When in a home or other building the client must remain /- 30 ft. to avoid a proximity
violation. For optimum performance the unit should be in an upright position at all times. When the cuff
bracelet is cut/ removed by the client a cuff violation will be communicated to the customer.
Charger Installation Procedure:
In addition to the Personal Tracking Unit (PTU) each client will be provided with a battery charger, surge
suppressor and cable. When set up properly, these three components will allow connection to the client’s
home phone line while charging (Reference Figure 1).
1.0
Assure the surge suppressor telephone plug is connected to charger
1.1
Assure ground (green wire) is securely attached to the ground lug on the charger.
1.2
Connect the telephone cable between the surge suppressor jack and telephone jack in the
home/office.Connect the battery charger to grounded AC power outlet (110 V, 10 amp minimum).
Note: The charger is now ready for charging the batteries in a ABSComtrack
1700.