background image

 

 Part number 20079, Rev 0 

 

FREEZER OPERATION 

After the unit is properly installed and power is applied, it will take some time before the 

system is cooled down to temperature and cycling normally. You should wait 8 hours on the 

first startup before beginning to add product to the unit. This ensures that the unit is installed 

and operating properly before being put into service. On subsequent startups (after cleanings, 

for example), this wait time can be reduced to about 4 hours.   After this wait time, the unit 

should be cycling in the desired temperature range. The units are calibrated before leaving the 

factory, so no adjustment should be necessary.  

Loading the units will again cause temperature to rise as the warmer product is introduced into 

the compartment. If a large amount of product is to be introduced, it is a good idea to do it in 

stages, allowing several hours between stages to allow temperature to stabilize again before 

introducing additional warm product. This will minimize the temperature transient while 

loading. Other tips for successful loading include:  

-

 

Leave about 2-3 inches of free space along the back and sides of the unit to allow for proper 

air flow and, therefore, more even cooling of the product.  

-

 

When loading the top shelf, avoid blocking the evaporator fan(s) (if installed). There should 

be at least 4 inches of clearance below the fan(s) to allow proper air flow.  

-

 

Do not overload the unit. Recommended maximum load is about 75% of the chamber 

volume. Additionally, the load should be distributed evenly from top to bottom and side to 

side for best results.  

These freezers come with  5  interior doors  (one for each shelf)  to help minimize the 

temperature transients resulting from opening the main door. You should still minimize the 

time the freezer door is open. On top of letting the cold air out, you are also letting warm, 

moist air in which will result in the buildup of more frost in the unit.  

Model ABT-3020AP has an auto-defrost feature.  Every 6 hours, it will go into a defrost cycle to 

remove frost build-up. During this cycle, which can last up to 25 minutes, the compressor is 

turned off and defrost heaters are turned on in the evaporator section. This will cause a 

temperature transient which will be seen in air temperature  inside the unit but should not 

significantly affect product temperatures. The other models need to be periodically defrosted. 

This procedure is located in the Maintenance and Cleaning section of this manual.  

Remember that the units are calibrated to the desired temperature range before leaving the 

factory. We also do extensive testing to ensure that these temperatures will result in product 

temperatures in the desired band. There should be no need to adjust the temperature control 

on these units, but if it is necessary, they can be adjusted using the manual thermostat on the 

back of the unit

.  

It is STRONGLY RECOMMENDED that you contact the manufacturer’s  Technical Support 

Department prior to performing any temperature adjustments to ensure the adjustment is 

necessary and, if so, it is performed correctly.

  

Summary of Contents for ABT-2020MP

Page 1: ...of delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When concealed damage is discovered stop unpacking immediately and contact the carrier immediately to report the claim and request an inspection This should be done as soon as possible and in any case must ...

Page 2: ...URER S TECHNICAL SERVICE DEPARTMENT please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left upper wall of the unit For convenience you may want to record the following information here for easy access in the future Model number __________________________________ Serial n...

Page 3: ...ry receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along with a formal request for an inspection report Follow up with a phone call Their contact information can be found on the carrier s web site The second type of shipping damage is concealed damage This t...

Page 4: ...the screw type adjustable leveling legs on the front corners of the unit Turn counterclockwise to raise the corner turn clockwise to lower it The unit may have a slight tilt from front to back after the legs are installed This is acceptable and is actually recommended POWER SOURCE The supply circuit to this cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial ...

Page 5: ...ALLATION not applicable to all models Hook shelf clips onto pilaster strips see Illustration Position all four shelf clips equal in distance from the floor for flat shelves Wire shelves are oriented so that cross support bars are facing down Place shelves on shelf clips making sure all corners are seated properly TEMPERATURE CONTROL NOTE The controls are preset at the factory to provide the desire...

Page 6: ...mum load is about 75 of the chamber volume Additionally the load should be distributed evenly from top to bottom and side to side for best results These freezers come with 5 interior doors one for each shelf to help minimize the temperature transients resulting from opening the main door You should still minimize the time the freezer door is open On top of letting the cold air out you are also let...

Page 7: ...iated with the alarm system i e delay times system status a battery backup which will maintain the alarm system for several hours after a power failure to allow for continued alarm and notification functions The temperature monitor system does NOT control the temperature of the unit That function is performed by the Microprocessor Digital Temperature Control which is preset at the factory and shou...

Page 8: ... pressed The MUTE PROGRAM button has three functions In Normal Run mode if the unit is beeping pressing the button will mute the beeper for a preset time Each time the button is pressed the mute time resets Holding the button down for two seconds takes the unit out of Normal Run mode and into Programming mode At the same time it mutes the beeper When in Programming mode pressing the button steps t...

Page 9: ...d the BEEPER and ALARM LED will both activate Press the MUTE PROGRAM button to stop the beeper for a specified time changing the sound to short chirps When the temperature goes back within range and there are no out of range readings for thirty seconds the chirping stops and the MUTE PROGRAM button resets If another out of range condition then occurs the beeper will again start at full volume Afte...

Page 10: ...in a short period 5 Once the Monitor is in Programming mode each time the Mute button is pressed the display steps to the next parameter As the display steps to the next parameter the value of the previous parameter is saved Once the final parameter is reached pressing the MUTE button returns the monitor to Normal Run mode saving the final parameter Description of Parameters for Control Center Hi ...

Page 11: ...emote Alarm Relay is a single pole double throw SPDT relay that changes state switches with the loss of line power or with the presence of an alarm condition NOTE The relay is rated for pilot duty operation only Do NOT use it for control switching The relay contacts and connections are rated at 30v 1A In normal applications the relay signals remote alarms or central monitoring systems that an alar...

Page 12: ...e of the unit A touch keypad allows the user to easily select the display units set point differential set point and heating or cooling mode Please Note The digital temperature controller has been factory set and tested to allow your unit to operate at its desired temperature cycle Adjusting the settings on the controller will alter these factory settings WE STRONGLY RECOMMEND YOU CONTACT THE MANU...

Page 13: ...t point and S1 will be blinking Press the up and down keys to adjust to the desired setting S1 blinking Set point Temperature Press SET key again to access the differential mode The LCD will display the current differential and DIF1 will be blinking Press the up and down keys to adjust to the desired setting DIF 1 blinking Differential Temperature Press SET key again to access the cooling or heati...

Page 14: ...ry EP Appears when the probe is open shorted or sensing a temperature that is out of range Check to see if the sensed temperature is out of range If not check for probe damage by comparing it to a known ambient temperature between 30 F and 220 F Replace the probe if necessary EE Appears if the EPROM data has been corrupted This condition cannot be field repaired Replace the control CL Appears if c...

Page 15: ...eplacements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or side walls Evaporator is blocked by frost or ice Remove the products unplug the refrigerator or freezer power and allow the unit to defrost If the problem still exists call for service 3...

Page 16: ...vent leakage Door will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal MOISTURE DURING THE SUMMER SEASON The amount of moisture condensation or high humidity related issues increase during the summer and in most cases will self resolve when the weather cools down Please note a refrigerati...

Page 17: ...ing soda in 1 quart of warm water Be sure to wring excess water out of sponge or cloth before cleaning around controls light bulb or any electrical parts Door Gaskets Soap and water Wipe gaskets and their seating surfaces with a clean soft cloth Shelves Soap and water Do not wash removable shelves in dishwasher Exterior and Handles Soap and water Non Abrasive Glass Cleaner Do not use commercial ho...

Page 18: ... pan occasionally to ensure it does not overflow A inch garden hose adaptor available at most hardware stores can be used to drain the freezer directly into a floor drain Replace the drain plug when defrosting is complete so warm air does not enter the freezer through the hole Defrosting tips If the frost is soft remove it with a plastic scraper If the frost is glazed and hard fill deep pans with ...

Page 19: ...TY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship under normal use and service for a period of three 3 additional years from the end of the initial two 2 year warranty period but not to exceed five 5 years after shipment from Horizon Scientific Inc...

Page 20: ...ood or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage caused by the storage of any corrosive material that comes in contact with the interior or exterior portions of the cabinet or the use of spark producing equipment or containers such as galvanized or carb...

Reviews: