RECHARGING NI-MH BATTERY

1. To maximize the life of the battery, power is automatically shut

off after 10 minutes of non-use or user-defined interval.
Automatic shut off is bypassed during USB output or when
used with the AC adapter/charger.

2. Battery icon will flash when the tester needs to be

recharged.

3. Push

to turn off power. Only use the IMADA AC adapter/

charger provided, AD120 for 115VAC, AD230 for 230VAC. Plug
into the correct AC output. It takes 10 hours to charge fully.

4. When the tester is turned off, make sure the AC adapter/charger

is disconnected to avoid overcharging.

OPTIONAL CABLES

10' Analog cable

CB-104

10' RS-232C cable, 9 pin female

CB-204

10' Digimatic Cable

CB-304

If High and Low setpoints have been programmed (see page 5),
for example, 5 lbf-in is set as Low and 10 lbf-in as High, the
ORANGE LED light for measurements less than 5 lbf-in (Low set-
point). GREEN lights between 5–10 lbf-in and RED lights over 10
lbf-in (High setpoint). Setpoint output is available through the
Communications port (see page 7).

After measuring, press the 

button to transmit data to:

RS-232 models:

RS-232C or Digimatic devices 

Storing Data into Memory

During measurement whether Peak or Real Time, press 

to store

and display up to 1,000 torque values into memory. (If no data is

stored 

– – – – – 

is displayed then flashing CF9 with solid End).

Tare

Clamp container firmly to the sample table (C) by tightening the

clamp handle (A). If necessary, press 

to tare before the test.

Pressing 

also clears the peak reading. 

Grip the sample lid and rotate to open (CCW) or close (CW). The

display will indicate the torque value with CCW

or CW

icons.

(A) CLAMP HANDLE

(C) SAMPLE TABLE

CONTAINER

Clamp container, then twist
sample lid by hand to 
measure torque.

Summary of Contents for DTX2

Page 1: ... authorization number and return the defective product to us with freight prepaid The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY and we hereby disclaim all other warranties express statutory or implied applicable to the products and or software including but not limited to all implied warranties of merchantability fitness non infringement results accuracy security and freedom f...

Page 2: ...its between lb in kg cm and N cm Programmable Setpoint LED s When high low setpoints are set LED indicates below NG within OK or above set point value NG CW icon Displayed for CW measurements CCW icon Displayed for CCW measurements Battery icon Flashes when the NI MH cells need to be charged PEAK icon When continuously displayed peak function is activated HOLD icon Displays when external hold sign...

Page 3: ...se inter nal Ni MH batteries without plugging into AC power Turn on the tester and check that the display is at zero and overload indicator is not flashing PRECAUTIONS DTX2 Cap Torque Tester is a sensitive instrument The load cell can be damaged regardless of whether the unit is ON or OFF Follow these precautions to keep your DTX2 from being damaged 1 Do not exceed unit s capacity regardless if po...

Page 4: ...apid torque changes over time Larger numbers allow more dampening Press SEND to select CF9End displays press SEND to exit Torque dampening rate displays each time the tester is turned on CF9 m2 indicator Default SC OFF Press PEAK or ZERO to cycle SC OFF CW and CCW or SC On CW and CCW Press SEND to select CF9End displays press SEND to exit Power Off programming clear data from memory Turn off the t...

Page 5: ...LO displays then the low set value i e L 5 0 Press PEAK to increase and ZERO to decrease press SEND to select CF9 End displays Press SEND again to exit CF9 F2 Peak mode Default Or Press SEND Or or And displays Press PEAK or ZERO to cycle Press SEND to select Or Peak records the Peak in either CW or CCW during test And Peak records both the CW peak and CCW peak during a test Zero reset memory store...

Page 6: ...example 5 lbf in is set as Low and 10 lbf in as High the ORANGE LED light for measurements less than 5 lbf in Low set point GREEN lights between 5 10 lbf in and RED lights over 10 lbf in High setpoint Setpoint output is available through the Communications port see page 7 After measuring press the button to transmit data to RS 232 models RS 232C or Digimatic devices Storing Data into Memory During...

Page 7: ... Choose between the following download methods Digimatic Data Download from Memory 1 Connect the tester and device receiving data with CB 304 cable 2 Turn on the tester Press and for 3 seconds to enter Power On programming CF9 flashes with solid F0 3 Press to transmit all data 4 Press again to exit RS 232C Data Download from Memory Connect the tester and device receiving data with a CB 204 cable U...

Page 8: ...arity Baud Rate 19200 bps RS 232C INTERFACE FUNCTIONS Upper case ASCII format COMMAND FUNCTION RESPONSE T CR Select real time mode R CR P CR Select peak mode R CR If OR peak is programmed P CR peak If AND peak is programmed P CR 1st time peak P CR 2nd time peak Z CR Tare Display R CR D CR Transmit display data direction value units mode go nogo overload CR direction CW CCW value 4 digits w decimal...

Reviews: