Function description (Using Touch library)
A96T418GDN Shield Board quick Guide
26
4.1.1.10
#define DETECT_DEBOUNCE_CNT_VAL [n]
4.1.1.11
#define RELEASE_DEBOUNCE_CNT_VAL [n]
━
Debounce is used to remove glitch noise.
━
If the debounce count is too large, it takes a lot of time for touch recognition and release
recognition, so you need to set the appropriate value.
━
Setting range (0 ~ 5) : default 0
Figure 25. Debounce Count
4.1.1.12
#define FILTER_IIR_GAIN_VAL [n]
━
This function sets offset value of the IIR filter.
━
data(n) = (data(n-1) * offs data(n)) / (offs 1)
━
The recommended setting is 1, which may affect operability if set too high.
━
Setting range (0 ~ 5) : default 0
Figure 26. IIR-Filter