STKS A96T418GDN Shield Board quick Guide
Function description (Using Touch library)
25
4.1.1.7
#define TOUCH_PORT_SEL_VAL [n]
━
Touch sensing channel port setting
━
Default output Low
Figure 24. Touch sensing channel port setting value (in touch_lib.h)
4.1.1.8
#define TOUCH_VHS_VAL [n]
━
Applies to 'Hisense Mode' only
━
A value greater than the value of ' TOUCH_COMP_REFV_VAL ' must be set.
━
Setting range (3000 ~ 5000) : default 4000
4.1.1.9
#define TOUCH_COMP_REFV_VAL [n]
━
the actual use area should only be used for an area larger than VDD/2.
━
Setting range (2700 ~ 4500) : default 3700