Valve is
properly
connected and
controlled, but
rotor does not
turn.
The NBR stator is not compatible
with the dosing medium, causing
it to swell. This jams the rotor,
and the programmed flow monitor
shuts the valve off.
Check stator and replace if
needed (see
“Replacing the
stator”)
Maintenance
The specified maintenance intervals are for single shift operation. Maintenance has
to be carried out more often depending on the field of application, medium and in
case of operation in more than one shift.
When
What
How
Who
Daily
Check the Rotary
Dosing Unit for leaks
Visual
Operating company
technicians
Weekly
Check all threaded
connections and
fittings for leaks
Visual
Operating company
technicians
Weekly
Check seals for
damage and wear
Visual
Operating company
technicians
Weekly
Remove general dirt
deposits from the
device
"lint-free", dry cloth
Operating company
technicians
Annually
Complete
maintenance
Replace brittle hoses
and leaking seals
Operating company
technicians
Customer service/support
ABNOX AG
Langackerstrasse 25
CH-6330 Cham
Switzerland
Phone
+41 (0) 41 780 44 55
Fax
+41 (0) 41 780 44 50
Internet
www.abnox.com
CAUTION
The product always has to be shut off prior to all work. The pneumatic and
hydraulic systems have to be de-pressurised. The pressure gauges have
to show 0 bar.