15
8 Opening speed and hold open time
Adjust the opening speed.
A slow door is a safe door. The door speed should be set to allow
unhindered access but as slow as is possible.
min
max
SPEED
Adjust the hold open time (0...60 s).
Full right position (seq) means that every other impulse either opens or closes
the door.
0
60
HOLD
OPEN
seq
Time (sec)
Door weight (kg)
Door width
(mm)
60
80
800
2,7
3,2
1000 3,4
4,0
1200 4,1
4,7
1300 4,5
5,1
Minimum safe opening and closing times for door of
various widths and weights are summarized in the table.
19 Test the operation
Note! Long hold open time increases the safety of the door.
- Turn mode switch to AUTO.
- Test the operation.
- If the function is not as desired, turn mode switch to MAN and repeat steps
4...10.
Resetting operator to factory settings (operator is moved to new door)
- Turn mode switch to OPEN.
- Push TEACH-button brie
fl
y. After that push TEACH-button 5 sec. Door open
and closed position information is removed from the memory.
Summary of Contents for DA430
Page 4: ...4 1 REVISION Following pages have been revised Page Revision As at 21 09 2009 ...
Page 26: ...26 ...
Page 27: ...27 ...