Special Function Log in /out 

19 

 

Enter or Reconfirmed 

20 

 

Utility Input Normal LED 

21 

 

Bypass Input Normal LED 

22 

 

UPS under Redundancy Mode 

23 

 

UPS under ECO Mode 

24 

 

UPS Fault or Abnormal Warning LED 

25 

EPO 

Emergency Power Off 

26 

Er05 

Battery Weak or Dead 

27 

Er06 

Output Short Circuit 

28 

Er10 

Inverter Over-current 

29 

Er11 

UPS Overheat 

30 

Er12 

UPS Output Overloading 

31 

Er14 

Fan error 

32 

Er15 

Wrong Procedure to enter Maintenance Mode 

33 

Er16 

Output Parameters Set Error in Parallel 

System 

34 

Er17 

ID Numbers are in conflict in Parallel System 

or ID number Error in single unit 

Summary of Contents for ODIN

Page 1: ...ODIN Parallel Redundancy On Line UPS 6K 10KVA User s Manual...

Page 2: ...1 Unpacking 13 3 2 Selecting Installation Position 14 3 3 Installation of Accessories Kit 14 3 4 Terminal Block Explanation 15 3 5 Operation Test and Installation Instruction 18 4 Troubleshooting Gui...

Page 3: ...pen the case as there are no serviceable parts inside Your Warranty will be void 1 1 7 Do not try to repair the unit yourself contact your local supplier or your warranty will be void 1 1 8 Please ens...

Page 4: ...cal security applications and operating equipments Non authorized technician is not allowed to install the UPS in the following areas a Medical equipment directly related to human life b Elevator Metr...

Page 5: ...for AC output circuit To reduce the risk of fire connect only to a circuit provided with branch circuit over current protection for 30 amperes for 6Kva for 50 amperes for 10Kva rating in accordance wi...

Page 6: ...150 of rating it switches to bypass mode immediately It will automatically switch back to inverter mode once overload condition ceases 2 1 5 Should the output becomes short circuit the UPS holds the s...

Page 7: ...reduce annoying noise because of sudden fan spin It remains your office quiet and comfortable as usual 2 1 14 When UPS is out of order the possible faulty will be display on the LCD screen which may r...

Page 8: ...A Blackout Transfer occurred in UPS Output 7 Bypass Input Abnormal UPS fails to transfer to bypass Bypass Abnormal at ECO mode 8 Utility Input Abnormal 9 OFF UPS Shutoff 10 LINE OFF UPS Abnormal Lock...

Page 9: ...ormal Warning LED 25 EPO Emergency Power Off 26 Er05 Battery Weak or Dead 27 Er06 Output Short Circuit 28 Er10 Inverter Over current 29 Er11 UPS Overheat 30 Er12 UPS Output Overloading 31 Er14 Fan err...

Page 10: ...ypass input 37 Er27 The UPS must be operated in normal mode in parallel system 38 Er28 Bypass Overload Time out and cut off output 39 Er31 The settings of both control board and driver board are not m...

Page 11: ...he Utility input voltage is within the window the LED flashes flickeringly to indicate that the Utility input voltage is within the acceptable window Green LED lights up to indicate Bypass Input is no...

Page 12: ...Holes for External Charger Cabinet N EPO Emergency Power Off Short to enable the function P Air Ventilation Hole 10KVA 6KVA Parallel Work Comm Bus Not Intended to TNV ON OFF S1 E P O SLOT G E X T B A...

Page 13: ...For other applications like Novell NetWare Unix Linux please contact your local distributor for a proper solution When the optional interface cards are used together with onboard RS232 port in commun...

Page 14: ...Unpacking 3 1 1 Take the UPS out of the PE foam 3 1 2 Unwrap the UPS 3 1 3 Standard Package includes 1 set of User s Manual 1 set of UPS communication software with RS232 cable 1 set of Metal Accesso...

Page 15: ...ep at least 30cm 12 inches clearance from the rear panel of the UPS to the wall 2 Do not block the air flow to the ventilation openings of the unit 3 Please check the installation site to avoid overhe...

Page 16: ...15 EVOLPACK 6KVA TB1 TB2 EVOLPACK 10KVA 3 4 Terminal Block Explanation...

Page 17: ...working under Utility mode G1 the terminal for UPS Input Ground L21 N22 the terminals for UPS Output G2 the terminal for UPS Output Ground Remarks 1 The maximum current for each terminal is 30Arms fo...

Page 18: ...nd recommended conductors listed as below a AC input and output 75 C minimum copper wire b Battery input Model Maximum Current Conductor Section Torque force 6KVA 33A AWG 9 10KVA 54 3A AWG 6 23 lb in...

Page 19: ...he voltage of Utility matches with the input voltage window of the UPS 3 5 1 4 Connect the Utility separately to the terminal blocks of UPS Utility and Bypass Inputs Switch on the Power Breaker of the...

Page 20: ...ess the UPS On Switch for approx 3 seconds then the Buzzer sounds twice and the LCD display changes from drawing B to drawing C C 3 5 1 7 Then the UPS is under self test mode again the LCD display wil...

Page 21: ...pcs of 12V 7AH batteries 3 5 2 2 Push the UPS On Switch once for approx 5 seconds to awake the UPS and then the buzzer sounds twice The LCD display will illustrate from drawing A to drawing G and keep...

Page 22: ...own key pads When you use scroll down key pad the LCD display will illustrate as Drawing C Voltage from Utility Input Drawing I1 Voltage from Bypass Input Drawing J Frequency from Utility Input Drawin...

Page 23: ...frequency from Utility Input 50 Hz or 60 Hz K It shows frequency from Bypass Input L It shows UPS output Voltage 120 Vac or 220 Vac M It shows UPS output frequency 50 Hz or 60 Hz N It shows UPS outpu...

Page 24: ...It shows UPS Inner Temperature 3 5 4 UPS Default Data and Special Function Execution 3 5 4 1 After UPS completely starts up press key pad to change the LCD display screen to drawing Q1 Q1 It shows bu...

Page 25: ...ltage Windows Drawing T Output Frequency Synchronization Window Drawing U Inverter Output Voltage Drawing V1 UPS Operation Mode Drawing W Output Voltage Micro Tune Value Drawing X UPS Id Drawing Y Par...

Page 26: ...shows Frequency Window is 3Hz U It shows inverter output voltage V1 It shows the UPS is operated in normal mode V2 It shows the UPS is operated in Eco mode V3 It shows the UPS is operated in CVCF 50H...

Page 27: ...3 5 4 3 Press scroll up key pad you may execute special functions The Functions includes buzzer ON as drawing Q1 or buzzer OFF as drawing Q2 Alarm silence for UPS Warning and self test OFF As drawing...

Page 28: ...ac or 240Vac 3 5 5 7 Drawing V1 V2 V3 and V4 mean the operation modes of the UPS of which alternative is Online Eco Economic mode fixed 50Hz Output or fixed 60Hz Output 3 5 5 8 Drawing W means the adj...

Page 29: ...the UPS lock please proceed the followings 3 5 6 3 1 Check those error messages recorded 3 5 6 3 2 Check to see Chapter 2 2 to trouble shoot the problem of the UPS Otherwise consult your local distri...

Page 30: ...er of the LCD screen will show sign 3 5 8 1 3 Turn off the UPS Utility breaker as well as Bypass Input Breaker you then may proceed UPS maintenance now 3 5 8 1 4 To repeat 3 5 1 4 you may put the UPS...

Page 31: ...the followings a Are the wirings of input and output correct b If the input voltage of the Utility is within the input window of the UPS In case problems or symptoms still exist please proceed the fol...

Page 32: ...new one 3 Remove the short circuit occurred at the EPO terminal 4 Remove the objects blocked onto the ventilation holes 5 Check the cooling fans on rear panel are working normally 6 Make sure the UPS...

Page 33: ...32 UPS locks itself and it can not be turned off Please refer to chapter 3 5 6 to trouble shoot the problem otherwise consult your local distributor for help...

Page 34: ...S232 cable to the UPS communication port 2 Connect the female connector of the RS232 cable to a dedicated RS232 port of the computer 3 For optional interface cards you may refer to Chapter 6 for insta...

Page 35: ...of the terminal resistor Short pin1 2 to enable the function and short pin2 3 to disable it 6 2 2 CN2 for RS485 and CN3 for remote power 6 2 3 Definition 6 3 USE USB card 6 3 1 CN1 for USB 6 3 2 Defi...

Page 36: ...wn function will be activated after a 6 25Vdc is put between pin9 and pin10 for 5 seconds 6 4 3 The capacity of each relay contact is 40Vdc 25mA 6 4 4 Flexible signal output for N C Normal close or N...

Page 37: ...6 5 1 SNMP WEB card 6 5 1 1 For installation please refer to the user s manual attached with the card 6 5 2 Net Agent II Internal Card 6 5 2 1 For installation please refer to the user s manual attac...

Page 38: ...n 1 3 Transfer Time 0ms Load Crest Factor 3 1 acceptable Efficiency AC to AC Normal 90 Autonomy 6 min 4 min DC Start Yes BATTERY Type Sealed Lead Acid Maintenance Free 12V 7AH Sealed Lead Acid Mainten...

Page 39: ...ons WxDxH mm 440x543x132 440x680x132 Input Output Connection Hardwire External Battery Connection Plug in Play Net Weight Kgs 17 5 kg 26Kg Heat Dissipation 450W 600W 10K Leakage Current 3mA at Full Lo...

Page 40: ...39 192321142020000...

Reviews: