REPLACING THE BATTERY

 

Note

Once the battery is disconnected, the loads are not protected 

from power outages. 
1. 

Use a cross-type screwdriver to remove the four screws from bottom 
shell.   

2. 

Take-up top cover and battery cover. 

3. 

Loosen the black wire from the negative (-) terminal and red wire from 
the positive (+) 

4. 

terminal. 

5. 

Connect the battery leads to the new battery. 

6. 

Note: Small sparks at the battery connectors are normal during connection. 

7. 

Slide the battery into the UPS. 

8. 

Close the front panel and fasten two screws. 

9. 

Dispose of the old battery properly at an appropriate recycling facility. 

 
 

                                 

     
 

       

   

 

TROUBLE SHOOTING

 

Should the UPS fail to function correctly we 
recommend you perform the following tests 
before calling the service. 
Check step: 
Step 1: Is the main switch in the 

“ON” position? 

Step 2: Is the UPS plugged into the mains 
power supply? 
Step 3: Does the power supply fall within 
specified unit values? 
Step 4: Has the fuse gone in the mains plug? 
Step 5: Is the UPS overload? 
Step 6: Is the battery flat or defective?

 

Situation 

Check Items 

Solution 

No LED display on the front 

panel.

 

Low battery. 

Charge the UPS at least 6 hours. 

Battery fault. 

Replace the battery with the same type of battery. 

The UPS is not turned on. 

Press the power switch again to turn on the UPS. 

Alarm continuously sounds 

when the Utility is normal.

 

The UPS is overload.

 

Remove some loads first. Before reconnecting equipment, please verify 
that the load matches the UPS capability specified in the specs. 

When power fails, back up time 

is shorten.

 

The UPS is overload. 

Remove some critical load. 

Battery voltage is too low. 

Charge the UPS at least6 hours. 

Battery  defect.  It  might  be  due  to  high 
temperature  operation  environment,  or  improper 
operation to battery. 

Replace the battery with the same type of battery. 

The Utility is normal but LED is 
flashing.

 

Power cord is loose.

 

Reconnect the power cord properly.

 

 

 

GR 450 / 650 / 850    SPECIFICATIONS 

 

GR 1000 / 1500 / 2000    SPECIFICATIONS

 

Model   

GR 450 

GR 650 

GR 850 

GR 1000 

GR 1500 

GR 2000 

Capacity 

450VA/270W 

650VA/380W 

850VA/500W 

1000VA/600W 

1500VA/900W 

2000VA/1200W 

Input

 

Voltage 

220/230/240VAC 

Voltage range 

160~290Vac 

Output

 

Voltage Regulation 

+/- 10% 

Waveform 

Simulated Sine Wave 

Battery

 

Type & Number 

12V/5Ah x 1 

12V/7Ah x 1 

12V/9Ah x 1 

12V/7Ah x 2 

12V/7Ah x 2 

12V/9Ah x 2 

Charging time 

4-6 hours recover to 90% capacity 

Physical

 

Dimension(DxWxH, mm) 

292 x 100 x 140 

315 x 148 x 198 

Net Weight(kgs) 

5.5 

10.5 

11.8 

Packaging  Dimension(DxWxH, 
mm) 

321 x 137 x 226 

411 x 229 x 302 

Gross Weight(kgs) 

4.5 

5.5 

10 

11.5 

12.8 

Environment

 

Humidity 

0-90 % RH @ 0-40 C (non-condensing) 

Noise level 

Less than 40 dB 

Safety 

Security certificate 

CE 

 

GR-450/650/850

 

GR-1000/1500/2000

 

STEP1

STEP2

STEP1

STEP2