50
10. homeCLU
Connecting eMH1
Configuring eMH1
Connecting homeCLU
Pin 1
Pin 2
M (GND)
Pin 3
A (Data)
Pin 4
B (Data)
Pin 5
M (GND)
Pin 6
Data cable
opening
1
6
1
Insert the data cable through the
lower opening in the housing
base
2
Connect the free end of the data
cable with the plug-in connec-
tion inside the Wallbox The
plug-in connection is located on
the DaisyChain at the upper left
hand edge of the housing base,
next to the PE terminal
3
Crimp the RJ12 plug
onto the data cable
4
Connect the data cable
to the homeCLU unit
•
The data cable has at least 2
intertwined pairs of conductors
•
Data conductors A and B are
intertwined
•
Conductors A, B and M must be
connected following
the same pattern
Further information: See the
homeCLU installation manual and
www.abl.de
1
6
RJ12
DaisyChain