xFUME FLEX
10 Troubleshooting
BAL.0733.0 • 2021-01-11
EN - 21
10 Troubleshooting
Observe the attached “Warranty” document. In the event of any questions and/or problems, please contact your retailer or
the manufacturer.
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the device. The
product warranty will be rendered invalid if work is carried out on the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
CAUTION
• Before performing any maintenance and cleaning work, suitable safety measures must be taken.
• Maintenance and cleaning work on the device may only be carried out in areas with locally filtered forced ventilation.
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves, and safety shoes.
NOTICE
• Consult the documentation for the welding components.
Fault
Cause Troubleshooting
Insufficient extraction volume.
• Extraction arm is blocked.
• Remove the blockage from the
extraction arm.
6.2 Mounting the extraction arm
on page EN-10
• Close the extraction hood valve.
• Bring the extraction hood lever into
the vertical position and open the
valve.
6.4 Controlling the volume flow
on page EN-13
• Filter elements saturated.
• Replace the filter elements.
9.2.1 Replacing the filter pad on
page EN-18
9.3.1 Replacing the primary
filter on page EN-19
External extraction system does
not start.
• Power supply defective.
• Check the electrical connection.
• Check cable for damage.
• Electrical components defective.
• Check and replace if necessary.
• Motor protective switch defective.
• Check and replace if necessary.
Dust is escaping the system.
• Filter elements saturated.
• Replace the filter elements.
9.2.1 Replacing the filter pad on
page EN-18
9.3.1 Replacing the primary
filter on page EN-19
• Service door not closed.
• Close the service door.
Tab. 11
Troubleshooting