11 Disassembly
CAUTION
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
1
Disconnect the compressed air supply.
2
Remove the current clamp from the cable
assembly.
3
Remove the extraction hose(s).
4
Loosen the clamps on both sides and remove the
top section of the device.
5
Loosen the castors.