xFUME™ ADVANCED 115V – CSA
9 Maintenance and cleaning
EN
-
25
9.5 Replacing the turbines
WARNING
Electric shock due to electronic component damage
When replacing carbon brushes and turbines, electrical connections must be disconnected and
reconnected. Fatal electric shock may occur if electronic components become damaged or improperly
uninstalled in the process.
► The carbon brushes and turbines should be replaced only by a qualified electrician.
1
Loosen the clamps on the sides and remove the
top section with the handle.
2
Loosen the screws (4×) and remove the cover.
3
Dispose of the turbines in accordance with local
regulations.
4
Insert the new turbines, attach the turbine clamps,
and establish the electrical connection.
5