9 Maintenance and cleaning
9.1
Cleaning the wire guide
1
Unscrew the cable assembly on the machine side and lay it out in a stretched position.
2
Unscrew the nut
and pull out the spiral liner or PA liner.
3
Clean the wire conduit from both sides with compressed air.
4
Slide the adjusted spiral liner or PA liner into the wire conduit and secure with a nut.
9.2
Shortening the spiral liner
1
Lay out the cable assembly
(3)
in a stretched position.
2
Disconnect
the central connector
(2)
from the feed unit.
3
Screw on the retaining
sleeve
(1)
.
4
Replace the old spiral liner
(6)
with a new one and insert the stripped side into the central
connector
(2)
.
WARNING
Risk of injury
Serious injuries may be caused by parts swirling around.
• When cleaning with compressed air, wear suitable protective clothing, in particular safety
goggles.
NOTICE
• New and unused spiral liners or PA liners must be shortened to the actual length of the
cable assembly.
1
Retaining sleeve
2
Central connector
3
Cable assembly
4
Nut
5
Collet
6
Spiral liner
Fig.
6
Shortening the spiral liner
1
2
5
6
3
4